Summary
PRRES20203598
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
10/08/2020
10/13/2020
04/06/2021
01/11/2023
Locations
Contacts
IQ CONSTRUCTION, Address:P O BOX 6423, Phone:(816) 582-8100  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SAFEHOUSE ELECTRIC COMPANY, Address:P O BOX 1833, Phone:(816) 935-8113  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
BSHELTON@IQHOMEBUILDERS.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/14/2020 10/12/2020
Kim Brennan
Right-of-way
Corrective Action Required
10/12/2020

The right-of-way with dimensions must be provided on the plot plan. Please show the 60' R/W along SW Eagle View Dr.
Residential Plan Review Approved 10/14/2020 10/12/2020
Kim Brennan
Plot Plan Review Rejected 10/12/2020 10/08/2020
Kim Brennan
Right-of-way
Corrective Action Required
10/08/2020

The right-of-way with dimensions must be provided on the plot plan. Please show the 60' R/W along SW Eagle View Dr.
Residential Plan Review Approved 10/12/2020 10/08/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,169.81 $1,169.81 Paid 10/13/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/13/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 10/13/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 10/13/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 10/13/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 10/13/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/24/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/24/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 10/28/2020 10/28/2020
Misc
Corrective Action Required
10/28/2020
Immediate street cleanup required
Footing Inspection - Residential Passed 10/28/2020 (1:30) 10/28/2020 10/28/2020
Underslab Plumbing Inspection - Residential Passed 12/7/2020 12/7/2020 12/07/2020
All Rough Inspection - Residential Failed 1/13/2021 1/13/2021 01/13/2021
Misc
Corrective Action Required
01/13/2021
Portal frame- Fasten top plate to header with two rows of 16 D sinker 3 inch on center, See section view of detail -Provide and tighten anchor bolts per detail
All Rough Inspection - Residential Failed 1/19/2021 01/19/2021
Misc
Corrective Action Required
01/13/2021
Portal frame- -Provide and tighten anchor bolts per detail
Erosion Control Inspection Residential Failed 1/20/2021 01/20/2021
Misc
Corrective Action Required
10/28/2020
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -no further inspections until issues are resolved
Sewer Service Inspection - R Passed 1/28/2021 (Ready Now) 1/28/2021 01/28/2021
Water Service Inspection - R Partial 1/29/2021 1/28/2021 01/28/2021
Misc
Informational
01/28/2021
Partial approval from structure to metallic connection customer side of meter
Erosion Control Inspection Residential Failed 1/28/2021 01/28/2021
Misc
Corrective Action Required
01/20/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -no further inspections until issues are resolved
Water Service Inspection - R Passed 1/29/2021 1/29/2021 01/29/2021
Misc
Resolved
01/29/2021
Partial approval from structure to metallic connection customer side of meter
Erosion Control Inspection Residential Passed 2/4/2021 02/04/2021
Misc
Resolved
02/04/2021
-Erosion control requires continuous maintenance. Repair damaged sections within two business days -immediate street cleanup required -no further inspections until issues are resolved
All Rough Inspection - Residential Not Ready 2/5/2021 2/5/2021 02/05/2021
Misc
Corrective Action Required
01/19/2021
Portal frame- -Provide and tighten anchor bolts per detail
Misc
Corrective Action Required
02/05/2021
Not ready, contractors onsite
All Rough Inspection - Residential Failed 2/10/2021 2/10/2021 02/10/2021
Misc
Corrective Action Required
02/05/2021
-Minimum two anchor bolts per plate, garage & basement -Provide joist hanger in garage -Fireblock all through floor Penetrations -Fireblock concealed space, garage/dwelling separation wall at flex room -Fireblock vertical to horizontal at dwelling/garage separation wall in pantry -Minimum 12” field 6” edge exterior sheathing fastening throughout. Top of sheathing edge is below west wall 2 x 6 double top plate at entry -Complete electrical installation, lighting above island & whip below deck -Fireblock top plate penetrations. bedroom 4, Bedroom 3, bedroom 2 & stairs to basement -Anchor bolt within 12 inches of plate splices, basement -Deck not ready for rough inspection
Misc
Resolved
02/10/2021
Not ready, contractors onsite
Electrical Service Inspection Passed 2/5/2021 2/10/2021 02/10/2021
Gas Service Inspection - Residential Passed 2/5/2021 2/10/2021 02/10/2021
Gas Piping Inspection - Residential Passed 2/10/2021 02/10/2021
All Rough Inspection - Residential Failed 2/18/2021 2/18/2021 02/18/2021
Misc
Corrective Action Required
02/10/2021
-Minimum two anchor bolts per plate, garage -Fireblock all through floor Penetrations -Fireblock vertical to horizontal at dwelling/garage separation wall in pantry at DWV -Complete electrical installation, lighting above island & whip below deck -Fireblock top plate penetrations. bedroom 4, Bedroom 3, bedroom 2 & stairs to basement -Deck not ready for rough inspection
All Rough Inspection - Residential Not Ready 2/22/2021 2/22/2021 02/22/2021
Misc
Corrective Action Required
02/18/2021
-Fireblock all through floor Penetrations with code approved material -Fireblock top plate penetrations. bedroom 4 -Deck not ready for rough inspection OK TO INSULATE DO NOT ROCK
All Rough Inspection - Residential Passed 2/24/2021 2/24/2021 02/24/2021
Misc
Informational
02/24/2021
-Deck not ready for rough inspection
Piers/Caissons Inspection - Residential Passed 2/25/2021 (9:45) 2/25/2021 02/25/2021
Driveway Inspection Passed 4/6/2021 4/14/2021 04/14/2021
Occupancy Inspection - Codes Residential Failed 5/12/2021 5/12/2021 05/12/2021
Misc
Informational
05/12/2021
No deck inspection at all trades
Misc
Corrective Action Required
05/12/2021
Not ready for inspection. no building address, no water to fixtures, incomplete guardrails, open outlet boxes and so on
Occupancy Inspection - Codes Residential Failed 5/20/2021 5/20/2021 05/20/2021
Misc
Resolved
05/20/2021
No deck inspection at all trades
Misc
Corrective Action Required
05/12/2021
-All outstanding fees must be paid in full -Maintenance of erosion control methods is required until sod is in place -Final grade and sod -Remove trash & construction debris -Complete gutter and downspout installation -Downspouts to discharge minimum 36 inches from foundation -seal exterior penetrations -Seal between trimmer and foundation at third car -install weather strip at garage/pantry door -repair penetrations in rock, garage -Install exterior door hardware and secondary locking device at sliding glass doors -Properly secure handrail to basement -Properly secure duct support in basement -Laundry room requires AFCI and GFCI protection -deck- -post/beam connections per code -install joist hangers -proper connections at joists to ledger
Occupancy Inspection - Codes Residential Temporary C of O 5/26/2021 5/26/2021 05/26/2021
Misc
Corrective Action Required
05/20/2021
-Maintenance of erosion control methods is required until sod is in place -Final grade and sod -Downspouts to discharge minimum 36 inches from foundation -seal exterior penetrations -deck- -post/beam connections per code -proper connections at joists to ledger TCO VALID THROUGH JUNE 26, 2021
Occupancy Inspection - Codes Residential Full C of O 01/11/2023
Misc
Corrective Action Required
05/26/2021
-Maintenance of erosion control methods is required until sod is in place -Final grade and sod -Downspouts to discharge minimum 36 inches from foundation -seal exterior penetrations -deck- -post/beam connections per code -proper connections at joists to ledger TCO VALID THROUGH JUNE 26, 2021
Documents & Images
Date Uploaded File Type Document Name
10/08/2020 Application Form Permit Application
10/08/2020 Application Form License Tax Application
10/08/2020 2349 SW HICKORY LN - LOT 744 FINAL PLOT PLAN
10/08/2020 Approved Plans Approved Drawings
10/08/2020 Letter Codes Residential Plan Review
10/12/2020 2349 SW HICKORY LN - LOT 744 FINAL PLOT PLAN
10/12/2020 Plot Plan Approved Plot Plan
10/13/2020 Receipt Receipt for transaction:2020-006893
10/13/2020 Letter DS Building Permit
10/28/2020 Letter INSPECTION SUMMARY
10/28/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter Codes Residential Plan Review
01/13/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
02/04/2021 Letter INSPECTION SUMMARY
02/05/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
02/18/2021 Letter INSPECTION SUMMARY
02/22/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
02/25/2021 Letter INSPECTION SUMMARY
04/14/2021 Letter INSPECTION SUMMARY
05/12/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter INSPECTION SUMMARY
05/24/2021 Receipt Receipt for transaction:2021-003402
05/26/2021 Letter Codes Temporary Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home