Permit Application Status

PRRES20202940


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202940
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO DEFFERED ROOF TRUSS
09/11/2020
09/15/2020
07/23/2021
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
CURTIS@SABHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/15/2020 09/15/2020
Kim Brennan
Deck location
Corrective Action Required
09/11/2020

Deck location, with dimensions to property lines must be provided on the plot plan. Please show this as a covered patio
Residential Plan Review Approved 09/15/2020 09/11/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $987.07 $987.07 Paid 09/15/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/15/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/15/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 09/15/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 09/15/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 09/15/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Passed 10/20/2020
Underslab Plumbing Inspection - Residential Passed 10/20/2020 10/20/2020 10/20/2020
Piers/Caissons Inspection - Residential Passed 11/4/2020 (3:00) 11/4/2020 11/04/2020
Sewer Service Inspection - R Passed 11/24/2020 (8:00) 11/24/2020 11/24/2020
Water Service Inspection - R Passed 11/25/2020 (1:30) 11/25/2020 11/25/2020
Miscellaneous Inspection Passed 2/2/2021 2/2/2021 02/02/2021
Misc
Informational
02/02/2021
Upload to portal engineered repair documentation to damaged trusses
Footing Inspection - Residential Passed 03/16/2021
Piers/Caissons Inspection - Residential Failed 03/16/2021
Misc
Corrective Action Required
03/16/2021
No inspection report on file, provide third party inspection within 48 hours
Electrical Service Inspection Passed 3/16/2021 3/16/2021 03/16/2021
Gas Piping Inspection - Residential Failed 3/16/2021 3/16/2021 03/16/2021
Misc
Corrective Action Required
03/16/2021
-complete installation to exterior fireplace
Gas Service Inspection - Residential Failed 3/16/2021 3/16/2021 03/16/2021
Piers/Caissons Inspection - Residential Passed 03/16/2021
Misc
Resolved
03/16/2021
No inspection report on file, provide third party inspection within 48 hours
Misc
Informational
03/16/2021
approved 11/4/2020
Erosion Control Inspection Residential Failed 03/16/2021
Misc
Corrective Action Required
03/16/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours
All Rough Inspection - Residential Failed 3/16/2021 3/16/2021 03/16/2021
Misc
Corrective Action Required
03/16/2021
-Deck beam/Column connection per plan -Provide truss hold down device A1.A in garage -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Repair fire block that soffit to wall connection, garage/dwelling separation wall -Fireblock top plate penetration in laundry room -Provide lighting outlet box, bed 2 -Fireblock penetration and wood fire block at ceiling height, bed 2 -Nail plate protection at Conductor stud penetration, bed 2 -Fireblock top plate penetration, full bath -Complete plumbing installation, full bath -Repair and complete fireblock at master bath drop ceiling -Complete exhaust duct, master bath -Fireblock top plate penetration, master bath toilet room -Ensure exterior sheathing is properly fastened two wall framing members, throughout -Properly secure stud shoe, master closet -Secure bottom plate to floor, master bath -Properly install truss anchors, master bed -Replaced cut stud in loadbearing interior wall at kitchen exhaust duct -Complete exterior fireplace installation -Complete gas piping installation -Complete horizontal to vertical fireblock installation at basement furred out construction -Fireblock top plate penetration, basement east wall -Ensure all anchor bolts or properly tightened -Fireblock vertical to horizontal, electric fireplace In basement -Penetrations in floor joists shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member, several locations in first floor framing -Repair Vertical fireblock at DWV penetration, bed 4 right and left of window -Repair penetration in horizontal fireblock at DWV Penetrations, bed four above window and closet -Repair and continue fireblock, basement bath drop ceiling -fasten supply duct basement bath -Fireblock Penetrations in wood fire block, basement bath -Fireblock penetration in horizontal fireblock, bed three -Repair penetration and horizontal fireblock at DWV penetration, bed three closet -Complete exterior wall corner framing, bed three -First floor exterior and garage/dwelling separation wall bottom plate fastening per plan -Repair/replace full depth solid blocking over beams removed/damaged by other trades -Girder truss end bearing per plan, see roof framing notes -Provide engineer documentation for Truss field repairs
All Rough Inspection - Residential Failed 4/5/2021 4/5/2021 04/05/2021
Misc
Corrective Action Required
03/16/2021
-Properly install truss anchors, master bed -Complete exterior fireplace installation -Complete horizontal to vertical fireblock installation at basement furred out construction -Ensure all anchor bolts or properly tightened -Penetrations in floor joists shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member, several locations in first floor framing -Fireblock DWV Penetration in Vertical fireblock, Bed four closet
Gas Piping Inspection - Residential Passed 4/5/2021 4/5/2021 04/05/2021
Misc
Resolved
04/05/2021
-complete installation to exterior fireplace
Gas Service Inspection - Residential Failed 4/5/2021 4/5/2021 04/05/2021
Misc
Corrective Action Required
04/05/2021
Connect gas piping to exterior fireplace or provide cap and valve at branch termination
All Rough Inspection - Residential Passed 4/15/2021 4/15/2021 04/15/2021
Misc
Resolved
04/15/2021
-Properly install truss anchors, master bed -Complete exterior fireplace installation -Complete horizontal to vertical fireblock installation at basement furred out construction -Ensure all anchor bolts or properly tightened -Penetrations in floor joists shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member, several locations in first floor framing -Fireblock DWV Penetration in Vertical fireblock, Bed four closet -Provide engineer documentation for Truss field repairs
Gas Service Inspection - Residential Passed 4/15/2021 4/15/2021 04/15/2021
Misc
Resolved
04/15/2021
Connect gas piping to exterior fireplace or provide cap and valve at branch termination
Piers/Caissons Inspection - Residential Passed 6/15/2021 (8:00) 6/15/2021 06/15/2021
Driveway Inspection Passed 6/16/2021 6/16/2021 06/18/2021
Sidewalk Inspection Passed 6/16/2021 6/16/2021 06/18/2021
Occupancy Inspection - Codes Residential Failed 7/20/2021 7/20/2021 07/20/2021
Miscellaneous Correction
Corrective Action Required
07/20/2021
-Maintain erosion control until sod is in place -Final grade and sod -Splash blocks and sump pump extension -Obtain lawn sprinkler permit and backflow certification -Label all dedicated non GFCI outlets -Seal gap at beam pocket in garage floor -Seal drywall penetrations at door openers -Provide all counter top outlets required by code in kitchens -Provide AFCI protection for kitchen receptacles -Secure bubble cover at deck -Provide combo smoke/carbon monoxide detector outside of main floor bedroom -Break off set screw at hose bib -Provide missing joist hangers at deck joists
Occupancy Inspection - Codes Residential Full C of O 7/23/2021 7/23/2021 07/23/2021
Miscellaneous Correction
Resolved
07/23/2021
-Maintain erosion control until sod is in place -Final grade and sod -Splash blocks and sump pump extension -Obtain lawn sprinkler permit and backflow certification -Label all dedicated non GFCI outlets -Seal gap at beam pocket in garage floor -Seal drywall penetrations at door openers -Provide all counter top outlets required by code in kitchens -Provide AFCI protection for kitchen receptacles -Secure bubble cover at deck -Provide combo smoke/carbon monoxide detector outside of main floor bedroom -Break off set screw at hose bib -Provide missing joist hangers at deck joists
Plot Plan Inspection Passed 07/23/2021
Erosion Control Inspection Residential Passed 07/23/2021
Misc
Resolved
07/23/2021
-Erosion control requires continuous maintenance. Repair damaged sections within 48 hours
Documents & Images
Date Uploaded File Type Document Name
09/11/2020 Application Form Permit Application
09/11/2020 Application Form License Tax Form
09/11/2020 E717 - Air Combustion 9_11_2020
09/11/2020 Approved Plans Approved Drawings
09/11/2020 Letter Codes Residential Plan Review
09/15/2020 Plot Plan Approved Plot Plan
09/15/2020 Receipt Receipt for transaction:2020-006240
09/15/2020 Letter DS Building Permit
09/26/2020 2349 SW River Trail Rd LSMO Eagle Ridge Lot 717 SAB P 2020-2940 3rd Party Footing Inspection Report 9-25-20
10/14/2020 Approved Plans Approved Truss Package
10/14/2020 Approved Plans Approved Truss Layout
10/14/2020 Approved Plans Approved Drawings
10/20/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
11/04/2020 Letter INSPECTION SUMMARY
11/24/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
02/02/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/16/2021 Letter INSPECTION SUMMARY
03/23/2021 Piggyback Base Truss repair - I44180577_201470
03/23/2021 Girder Truss Repair - 44106531_201470
04/05/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/14/2021 DW Structural Framing Inspection Report 2349 SW River Trail Rd
04/15/2021 Letter INSPECTION SUMMARY
04/15/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
07/20/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter Codes Final Certificate of Occupancy
07/23/2021 Letter Field Certificate of Occupancy
07/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home