Permit Application Status

PRRES20202588


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202588
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
08/26/2020
08/28/2020
07/23/2021
Locations
Contacts
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
JIM@SABHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/28/2020 08/28/2020
Kim Brennan
Deck location
Corrective Action Required
08/26/2020

Deck location, with dimensions to property lines must be provided on the plot plan. Please show that this is a covered patio
Residential Plan Review Approved 08/28/2020 08/26/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $907.24 $907.24 Paid 08/28/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/28/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/28/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 08/28/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/28/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/28/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/9/2020 09/10/2020
Misc
Informational
09/10/2020
- 3RD PARTY FOOTING SIGNED & SEALED BY DAVID AINSWORTH - - COMMENTS: UFER GROUND LOCATED IN EAST SIDEWALL A FEW FEET BEHIND GARAGE WALL -
Erosion Control Inspection Residential Failed 9/16/2020 9/16/2020 09/16/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/16/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
09/16/2020
STREET CLEAN UP REQUIRED IMMEDIATELY Remove trash from site
Underslab Plumbing Inspection - Residential Passed 10/1/2020 10/1/2020 10/01/2020
Sewer Service Inspection - R Passed 10/5/2020 (9:15) 10/5/2020 10/05/2020
Water Service Inspection - R Passed 10/6/2020 (9:30) 10/6/2020 10/06/2020
Erosion Control Inspection Residential Passed 10/20/2020
DCM3 ESC REQUIRED 2 DAY
Resolved
10/20/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
10/20/2020
STREET CLEAN UP REQUIRED IMMEDIATELY Remove trash from site
Piers/Caissons Inspection - Residential Passed 12/7/2020 (1:00) 12/7/2020 12/07/2020
Electrical Service Inspection Passed 3/2/2021 3/2/2021 03/02/2021
All Rough Inspection - Residential Failed 3/2/2021 3/2/2021 03/02/2021
Misc
Corrective Action Required
03/02/2021
-Fireblock top plate Penetrations in garage & bed 2 -12” oc fastening, stud to stud and abutting studs at intersecting braced walls, garage -address damaged corner framing member in garage -Identify white insulated conductors to be used as current carrying conductors at both points of termination -Fireblock all through floor Penetrations -Provide electrical outlet boxes for whips above kitchen & great room -Fasten fireplace to framing -Seal penetration in studs where cavity is used as Plenum, bed 2 -Replace removed solid blocking and provide exterior bottom for front cantilever -repair/replace solid blocking over beams where damaged or removed from other trades -Provide outlet box for circuit at future bench in basement -Pressure test gas piping minimum 10 psi for 15 minutes -Repair return air pan in basement -Anchor steel columns -Solid blocking where joists run parallel with foundation per framing notes six and seven -Provide washers and nuts for anchor bolts at basement windows -plan indicates floor framing 4 LVL or steel beam from column to foundation wall, 2 LVL installed -missing 2 LVL above future bed 4 wall -(3) 2x4 under girder truss bearing in garage all other GT bearing support per roof framing notes -EC5 hold down device, master bed per plan -Interior wall bracing per plan -Attic access in garage -Address G8 to G1 connection in master bed -Trust hangers throughout per plan -Address damaged hanger between bed 2 and bathroom
Gas Piping Inspection - Residential Failed 3/2/2021 3/2/2021 03/02/2021
Misc
Corrective Action Required
03/02/2021
Pressure test gas piping
Gas Service Inspection - Residential Failed 3/2/2021 3/2/2021 03/02/2021
All Rough Inspection - Residential Failed 4/5/2021 4/5/2021 04/05/2021
Misc
Corrective Action Required
03/02/2021
-Fireblock top plate Penetrations in garage -Identify white insulated conductors to be used as current carrying conductors at both points of termination -Fasten fireplace to framing -repair/replace solid blocking over beams where damaged or removed from other trades -Provide outlet box for circuit at future bench in basement -Provide means to access attic space above living area from attic access in garage or provide second access
Gas Piping Inspection - Residential Passed 4/5/2021 4/5/2021 04/05/2021
Misc
Resolved
04/05/2021
Pressure test gas piping
Gas Service Inspection - Residential Passed 4/5/2021 4/5/2021 04/05/2021
All Rough Inspection - Residential Passed 4/7/2021 4/7/2021 04/07/2021
Misc
Resolved
04/07/2021
-Fireblock top plate Penetrations in garage -Identify white insulated conductors to be used as current carrying conductors at both points of termination -Fasten fireplace to framing -repair/replace solid blocking over beams where damaged or removed from other trades -Provide outlet box for circuit at future bench in basement -Provide means to access attic space above living area from attic access in garage or provide second access
Driveway Inspection Passed 6/15/2021 6/15/2021 06/16/2021
Occupancy Inspection - Codes Residential Failed 7/14/2021 7/14/2021 07/14/2021
Misc
Corrective Action Required
07/14/2021
-Breaker lock outs at hot water heater and oven breakers -AFCI and GFCI protection req at washer circuit -30 amp max overcurrent protection at AC compressor -Final grade and sod -Splash blocks at all downspout and sump pump discharge locations, min 36” discharge from foundation -Install emergency egress ladders at basement wells -Secure electrical whip within 12” of AC disconnect
Occupancy Inspection - Codes Residential Temporary C of O 7/15/2021 7/15/2021 07/15/2021
Misc
Corrective Action Required
07/14/2021
-Final grade and sod -Splash blocks at all downspout and sump pump discharge locations, min 36” discharge from foundation -Install emergency egress ladders at basement wells -Secure electrical whip within 12” of AC disconnect **OK FOR TCO - TCO EXPIRES 8/5/21**
Occupancy Inspection - Codes Residential Full C of O 7/23/2021 7/23/2021 07/23/2021
Misc
Resolved
07/23/2021
-Final grade and sod -Splash blocks at all downspout and sump pump discharge locations, min 36” discharge from foundation -Install emergency egress ladders at basement wells -Secure electrical whip within 12” of AC disconnect **OK FOR TCO - TCO EXPIRES 8/5/21**
Plot Plan Inspection Passed 07/23/2021
Documents & Images
Date Uploaded File Type Document Name
08/26/2020 Application Form Permit Application
08/26/2020 Application Form License Tax Application
08/27/2020 Letter Codes Residential Plan Review
08/27/2020 Approved Plans Approved Drawings
08/28/2020 Plot Plan Approved Plot Plan
08/28/2020 Receipt Receipt for transaction:2020-005809
08/28/2020 Letter DS Building Permit
09/09/2020 M L Crose 2350 SW River Trail Rd LSMO Eagle Creek Lot 712 SAB Permit 2020-2588 3rd Party Footing Inspection Report 9-9-20
09/10/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/30/2020 Approved Plans Approved Truss Layout
09/30/2020 Approved Plans Approved Truss Package
09/30/2020 Approved Plans Approved Revised Drawings
10/01/2020 Letter INSPECTION SUMMARY
10/05/2020 Letter INSPECTION SUMMARY
10/06/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter INSPECTION SUMMARY
04/07/2021 Letter INSPECTION SUMMARY
06/16/2021 Letter INSPECTION SUMMARY
07/14/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter Codes Temporary Certificate of Occupancy
07/23/2021 Letter Codes Final Certificate of Occupancy
07/23/2021 Letter Field Certificate of Occupancy
07/23/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home