Permit Application Status

PRRES20202389


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202389
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - UNFINISHED BASEMENT - COVERED DECK
08/18/2020
08/21/2020
05/24/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/20/2020 08/20/2020
Dylan Eppert
Property boundary
Corrective Action Required
08/20/2020

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. WEST BEARING IS NOT CORRECT PER PLAT.
Easements
Corrective Action Required
08/20/2020

All easements with dimensions must be provided on the plot plan. PLAT SHOWS 7.5" U/E NOT S/Y/S
Residential Plan Review Approved 08/20/2020 08/20/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,560.97 $1,560.97 Paid 08/21/2020
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 08/21/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 08/21/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/21/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/21/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/21/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/21/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/19/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/19/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 05/19/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/28/2020 (3:00) 8/28/2020 08/28/2020
Underslab Plumbing Inspection - Residential Failed 9/21/2020 9/21/2020 09/21/2020
Misc
Corrective Action Required
09/21/2020
NO INSPECTION PERFORMED - CLEAN MUD/GRAVEL IN STREET - POST ADDRESS - MUD/WATER COVERING DWV, PUMP OUT WATER FOR INSPECTION
Erosion Control Inspection Residential Failed 9/23/2020 9/23/2020 09/23/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/23/2020
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. CLEAN MUD/GRAVEL IN STREET
Underslab Plumbing Inspection - Residential Not Ready 9/23/2020 9/23/2020 09/23/2020
Misc
Corrective Action Required
09/21/2020
NO INSPECTION PERFORMED - EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. MAINTAIN SILT FENCE AROUND LOT. - CLEAN MUD/GRAVEL IN STREET - MUD/WATER COVERING DWV, PUMP OUT WATER FOR INSPECTION
Underslab Plumbing Inspection - Residential Passed 9/25/2020 9/25/2020 09/25/2020
Misc
Resolved
09/25/2020
All Rough Inspection - Residential Failed 12/15/2020 12/15/2020 12/15/2020
Misc
Corrective Action Required
12/15/2020
Inspection denied per Municipal Ordinance Sec. 7-1407. - Door frames. A. The exterior door frames shall be installed prior to a rough-in inspection. Door frames shall comply with Sections 7-1407.1—7-1407.3 for the type of assembly installed. Exceptions: 1. Screen or storm doors installed in addition to the buildings exterior door(s). 2. Exterior doors of structures within multi-family developments utilized to access interior common spaces such as hallways, laundry rooms and similar spaces. (Ord. No. 8584, § 1, 3-19-2019)
All Rough Inspection - Residential Failed 12/16/2020 12/16/2020 12/15/2020
Misc
Resolved
12/15/2020
Inspection denied per Municipal Ordinance Sec. 7-1407. - Door frames. A. The exterior door frames shall be installed prior to a rough-in inspection. Door frames shall comply with Sections 7-1407.1—7-1407.3 for the type of assembly installed. Exceptions: 1. Screen or storm doors installed in addition to the buildings exterior door(s). 2. Exterior doors of structures within multi-family developments utilized to access interior common spaces such as hallways, laundry rooms and similar spaces. (Ord. No. 8584, § 1, 3-19-2019)
Misc
Corrective Action Required
12/15/2020
-install exterior doors -Unable to verify fastening method PFH exterior, Fasten top plate to header with two rows or 16D at 3”OC, see section view of detail 12/S2.0 -Install flashing over third car garage opening -6 inch edge 12 inch field exterior sheathing fastening -Through bolts at deck/beam connection -EC #2 at third car -Provide nail plate protection for plumbing at entry door & nailer for rock -Provide all interior wall bracing per plan -Penetrations in joists require 2” minimum clearance penetrations, above entry area second floor joists -plumbing vent to extend minimum 6” vertical above flood level rim of fixture before turning horizontal, main level bath -Fireblock between top plates at fridge/pantry wall -12 inch on center fastening stud to stud in abutting studs at brace walls -Provide hold down device for girder truss in dining room -Exterior brace wall method CS-PF at dining room exterior door per plan -Exterior braced wall per plan, living room -fireblock top & bottom plate penetrations, hallway to master & bedroom 4 -Missing girder truss anchor and damaged girder truss anchor in bedroom two -Missing girder truss anchor bedroom three closet -Secure girder truss, bedroom for at mechanical chase -double top plate splices to offset minimum 24” -Double king stud headers over 10 foot master bedroom -nail plate protection of horizontal pex in master shower lid -Complete installation of mechanical equipment -Complete installation of DWV piping -Repair/replace solid blocking where joists run parallel with foundation -Identify white insulated conductors to be used as current carrying conductors at both points of termination -Pressure test gas piping -Anchor required within 12 inches of plate splice, cantilevered wall -truss lateral bracing per plan through out -2 bottom plates used to make plate for 2x6 wall, Both plates must be anchored and within the middle 1/3 of the plate, west basement wall at windows
Erosion Control Inspection Residential Failed 12/15/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/23/2020
Repair damaged sections of erosion control at curb lines Immediate Street clean up required No further inspections until issues are resolved
Electrical Service Inspection Passed 12/15/2020 12/15/2020
Gas Piping Inspection - Residential Failed 12/15/2020 12/15/2020
Misc
Corrective Action Required
12/15/2020
Pressure test gas piping
Gas Service Inspection - Residential Failed 12/15/2020 12/15/2020
Gas Piping Inspection - Residential Failed 12/22/2020 12/22/2020 12/22/2020
Misc
Corrective Action Required
12/15/2020
-SECURE GAS FLEX LINE AT FIREPLACE
Gas Service Inspection - Residential Failed 12/22/2020 12/22/2020 12/22/2020
Misc
Corrective Action Required
12/22/2020
-GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR TEST
All Rough Inspection - Residential Failed 12/22/2020 12/22/2020 12/22/2020
Misc
Corrective Action Required
12/15/2020
-install exterior doors -Install flashing over third car garage opening -Through bolts at deck/beam connection -Provide all interior wall bracing per plan - LIB per plans - office, bed/bath#1, -Penetrations in joists require 2” minimum clearance penetrations, above entry area second floor joists -Exterior braced wall per plan, living room -nail plate protection of horizontal pex in master shower lid -Complete installation of DWV piping -Clarification required on deck ledger attached to cantilever
All Rough Inspection - Residential Failed 12/29/2020 12/29/2020 12/29/2020
Misc
Corrective Action Required
12/22/2020
-install exterior doors -Complete installation of DWV piping -Clarification required on deck ledger attached to cantilever -OK TO INSULATE-
Occupancy Inspection - Codes Residential Failed 12/30/2020 12/30/2020
Misc
Corrective Action Required
12/30/2020
-PER JARED, THE MASTER BATH TUB NOT INSTALLED UNTIL FINAL. INSPECT THE DWV LINE FOR THE TUB AT FINAL AS IT WAS NOT COMPLETED AT ROUGH.
Gas Piping Inspection - Residential Failed 12/31/2020 12/31/2020 12/31/2020
Misc
Corrective Action Required
12/22/2020
-SECURE GAS FLEX LINE AT FIREPLACE
Gas Piping Inspection - Residential Passed 1/5/2021 1/5/2021 01/05/2021
Misc
Resolved
01/05/2021
Gas Service Inspection - Residential Passed 1/7/2021 1/7/2021 01/07/2021
Misc
Resolved
01/07/2021
All Rough Inspection - Residential Failed 1/7/2021 1/7/2021 01/07/2021
Misc
Corrective Action Required
12/29/2020
-Clarification required on deck ledger attached to cantilever -OK TO ROCK-
Sewer Service Inspection - R Passed 1/15/2021 (1:00) 1/15/2021 01/15/2021
Water Service Inspection - R Passed 1/19/2021 01/19/2021
Erosion Control Inspection Residential Failed 1/29/2021 1/29/2021 01/29/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
01/29/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/29/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -MAINTAIN SILT FENCE ON LOT, SILT FENCE REQUIRES CONTINUOUS MAINTENANCE -CLEAN ALL MUD AND GRAVEL FROM STREET
All Rough Inspection - Residential Failed 2/23/2021 2/23/2021 02/23/2021
Misc
Corrective Action Required
01/07/2021
-Deck ledger to cantilever attachment per plans - Ensure that attachment on site matches the referenced plan detail - specified galvanized lag bolts, rim joists with inverted hangers attached to cantilevered joists, blocking between joists at cantilever, etc. -OK TO ROCK-
Driveway Inspection Partial 2/26/2021 2/26/2021 02/26/2021
Misc
Informational
02/26/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 2/26/2021 2/26/2021 02/26/2021
Misc
Informational
02/26/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 3/5/2021 3/5/2021 03/22/2021
Misc
Informational
02/26/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 03/22/2021
Driveway Inspection Passed 3/5/2021 3/5/2021 03/22/2021
All Rough Inspection - Residential Passed 04/27/2021
Misc
Resolved
04/27/2021
Occupancy Inspection - Codes Residential Failed 4/27/2021 4/27/2021 04/27/2021
Misc
Corrective Action Required
12/30/2020
-Resolve outstanding inspection fee(s) before final c of o -Guardrail at front porch, more than 30” from grade -seal all penetrations in siding, seal along top of meter can and AC disconnect -security screws at master bed exterior door, (2) 3" screws at each hinge and at strike plate -garage door must be self closing -fireblock tub trap for master bath (tub not installed at rough in stage) -Install light or cover plate at covered deck ceiling box -required clearance at water meter well from top of meter to lid 14”-18”
Occupancy Inspection - Codes Residential Temporary C of O 5/19/2021 5/19/2021 05/19/2021
Misc
Corrective Action Required
04/27/2021
-Resolve outstanding inspection fee(s) before final c of o **OK FOR TCO - TCO EXPIRES 5/28/21**
Plot Plan Inspection Passed 5/24/2021 5/24/2021 05/24/2021
Erosion Control Inspection Residential Passed 05/24/2021
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/24/2021
Occupancy Inspection - Codes Residential Full C of O 5/24/2021 5/24/2021 05/24/2021
Misc
Resolved
05/24/2021
Documents & Images
Date Uploaded File Type Document Name
08/18/2020 Application Form RR #74 - PERMIT APP
08/18/2020 74 Reserve at Stoney Creek - Raising Hope House 2021 1st Floor Layout - Signed
08/18/2020 RR #74 - Sydney - Modern Prairie - Sheets - Signed
08/18/2020 LOT 74 FINAL 8-17-20
08/18/2020 400477
08/18/2020 74 Reserve at Stoney Creek - Raising Hope House 2021 2nd Floor Layout - Signed
08/19/2020 Drawing APPROVED TRUSS LAYOUT (2ND FLOOR)
08/19/2020 Specifications APPROVED TRUSS PACKAGE
08/19/2020 Drawing APPROVED TRUSS LAYOUT (1ST FLOOR)
08/20/2020 Letter Codes Residential Plan Review
08/20/2020 Plans APPROVED HOUSE PLANS
08/20/2020 Plot Plan APPROVED PLOT PLAN
08/21/2020 Receipt Receipt for transaction:2020-005503
08/21/2020 Letter DS Building Permit
08/21/2020 Specifications REVISED TRUSS PACKAGE
08/21/2020 REVISED TRUSS LAYOUT
08/28/2020 Letter INSPECTION SUMMARY
09/21/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter INSPECTION SUMMARY
09/25/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/22/2020 Letter INSPECTION SUMMARY
12/22/2020 Letter INSPECTION SUMMARY
12/22/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
12/30/2020 Letter INSPECTION SUMMARY
12/31/2020 Letter INSPECTION SUMMARY
01/05/2021 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/15/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter INSPECTION SUMMARY
02/23/2021 Letter INSPECTION SUMMARY
02/26/2021 Letter INSPECTION SUMMARY
02/26/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter INSPECTION SUMMARY
05/19/2021 Letter Codes Temporary Certificate of Occupancy
05/19/2021 Receipt Receipt for transaction:2021-003195
05/24/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter INSPECTION SUMMARY
05/24/2021 Letter Field Certificate of Occupancy
05/24/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home