Summary
PRRES20202176
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
08/05/2020
08/07/2020
06/07/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/07/2020 08/07/2020
Kim Brennan
Drainage swales
Corrective Action Required
08/05/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide
As-graded plot plan
Corrective Action Required
08/05/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Planning Review (RES) Approved 08/07/2020 08/05/2020
Kim Brennan
Residential Plan Review Approved 08/07/2020 08/05/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,279.91 $1,279.91 Paid 08/07/2020
Right of Way Permit Fee $80.00 $80.00 Paid 08/07/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/07/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 08/07/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 08/07/2020
Water Meter Fee $455.54 $455.54 Paid 08/07/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/31/2020 8/31/2020 08/31/2020
Underslab Plumbing Inspection - Residential Passed 9/24/2020 9/24/2020 09/24/2020
Electrical Service Inspection Passed 12/14/2020 12/14/2020 12/14/2020
Gas Piping Inspection - Residential Failed 12/14/2020 12/14/2020 12/14/2020
Misc
Corrective Action Required
12/14/2020
-SECURE GAS FLEX LINE AT FIREPLACE
Gas Service Inspection - Residential Passed 12/14/2020 12/14/2020 12/14/2020
All Rough Inspection - Residential Failed 12/14/2020 12/14/2020 12/14/2020
Misc
Corrective Action Required
12/14/2020
-Nuts missing on garage portal anchor bolts -Tighten all anchor bolts -H2.5 truss straps on all hip trusses - garage -Connect all 2x4 laid flat 3’ or more to floor joists to support the ceiling load at furred down in garage -Not less than (1) receptacle in addition to any provided for specific equipment in each vehicle bay. (3) car garage requires (3) receptacles -Protection plates at NM less than 1 1/4” from end of framing member, 1st floor NE bedroom at homerun -(4) nails at each side of structural straps at top plates -stud shoes at DWV kitchen exterior wall -Fireblock vertical to horizontal at chases in living room -Holes for pex bored less than 2” together in floor joist, 1st floor above living room -secure gas flex line at fireplace -Truss hangers per plans - garage -Remove lid at front porch to allow for inspection of trusses/hangers -Fireblock between floors at 2x6 wall - 1st/2nd floor stairway -Connect 2x6 top plate to 2x4 top plate- 2nd floor stairs -Bocca protection plate at DWV vent 2nd floor bath top plate -Nail dbl truss girders together per plans -LIB bracing per plans
Gas Piping Inspection - Residential Passed 12/22/2020 12/22/2020 12/22/2020
Misc
Resolved
12/22/2020
All Rough Inspection - Residential Failed 12/22/2020 12/22/2020 12/22/2020
Misc
Corrective Action Required
12/14/2020
-(4) nails at each side of structural straps at top plates -stud shoes at DWV kitchen exterior wall -Holes for pex bored less than 2” together in floor joist, 1st floor above living room -(5) LUS24 truss hangers at front porch trusses per plans -Bocca protection plate at DWV vent 2nd floor bath #2 top plate -Nail dbl truss girders together per plans -bed#4 -LIB bracing per plans -1st floor bath#4
All Rough Inspection - Residential Failed 12/23/2020 12/23/2020 12/23/2020
Misc
Corrective Action Required
12/22/2020
-Holes for pex bored less than 2” together in floor joist, 1st floor above living room -Bocca protection plate at DWV vent 2nd floor bath #2 top plate -Nail dbl truss girders together per plans -bed#4
All Rough Inspection - Residential Passed 12/28/2020 12/28/2020 12/28/2020
Misc
Resolved
12/28/2020
Sewer Service Inspection - R Passed 1/21/2021 (1:00) 1/21/2021 01/21/2021
Water Service Inspection - R Partial 1/28/2021 (2:00) 1/28/2021 01/22/2021
Misc
Corrective Action Required
01/22/2021
Partial approval from structure to metallic connection customer side of meter
Water Service Inspection - R Passed 1/28/2021 1/28/2021 01/28/2021
Misc
Resolved
01/28/2021
Driveway Inspection Passed 2/2/2021 (P.M.) 2/2/2021 02/02/2021
Misc
Informational
02/02/2021
On Tuesday, 2-02-2021. A driveway inspection was conducted and passed inspection.
Sidewalk Inspection Passed 2/2/2021 (P.M.) 2/2/2021 02/02/2021
Misc
Informational
02/02/2021
On Tuesday, 2-02-2021. Sidewalk inspection was conducted at location and passed inspection
Occupancy Inspection - Codes Residential Failed 3/4/2021 3/4/2021 03/04/2021
Misc
Corrective Action Required
03/04/2021
-As graded plot plan required prior to sodding, submit for review -Final grade -Sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36" discharge from foundation -Guardrail required at front porch, more than 30” from grade -Repair rock at garage ceiling, complete light fixture -security screws at back door (2) 3” screw each and strike plate -AFCI protection required at washer circuit
Occupancy Inspection - Codes Residential Temporary C of O 3/17/2021 3/17/2021 03/17/2021
Misc
Corrective Action Required
03/04/2021
-As graded plot plan required prior to sodding, submit for review -Final grade -Sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36" discharge from foundation -Guardrail required at front porch, more than 30” from grade OK FOR TCO - TCO EXPIRES 3/31/21
Occupancy Inspection - Codes Residential Temporary C of O 4/1/2021 4/1/2021 04/01/2021
Misc
Corrective Action Required
03/17/2021
-As graded plot plan required prior to sodding, submit for review -Final grade -Sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36" discharge from foundation -Guardrail required at front porch, more than 30” from grade OK FOR TCO - TCO EXTENSION - EXPIRES 4/19/21
Occupancy Inspection - Codes Residential Temporary C of O 4/19/2021 4/19/2021 04/19/2021
Misc
Corrective Action Required
04/01/2021
-As graded plot plan required prior to sodding, submit for review -Final grade -Sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36" discharge from foundation -Guardrail required at front porch, more than 30” from grade OK FOR TCO - TCO EXTENSION - EXPIRES 4/27/21
Plot Plan Inspection Failed 4/23/2021 04/23/2021
Misc
Corrective Action Required
04/23/2021
-UNCOVER AND RAISE TO GRADE IF NECESSARY MANHOLE MH 5-1 AS SHOWN ON PLOT PLAN AT FRONT OF LOT-
Occupancy Inspection - Codes Residential Failed 4/27/2021 4/27/2021 04/27/2021
Misc
Corrective Action Required
04/19/2021
-see plot plan inspection report concerning covered manhole -Sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36" discharge from foundation OK FOR TCO - TCO EXTENSION - EXPIRES 4/27/21
Occupancy Inspection - Codes Residential Failed 6/3/2021 6/3/2021 06/03/2021
Misc
Corrective Action Required
04/27/2021
-Uncover manhole front of lot as shown on plot plan -Sod NW corner rear lot at swale
Erosion Control Inspection Residential Passed 06/07/2021
Plot Plan Inspection Passed 6/7/2021 6/7/2021 06/07/2021
Misc
Resolved
06/07/2021
Occupancy Inspection - Codes Residential Full C of O 6/7/2021 6/7/2021 06/07/2021
Misc
Resolved
06/07/2021
Documents & Images
Date Uploaded File Type Document Name
08/05/2020 Letter Permit Application and license tax form
08/05/2020 Drawing Approved Drawings
08/05/2020 Drawing Approved Truss Layout
08/05/2020 Drawing Approved Truss Package
08/05/2020 Letter Codes Residential Plan Review
08/07/2020 Plot Plan Approved Plot Plan
08/07/2020 Receipt Receipt for transaction:2020-005027
08/07/2020 Letter DS Building Permit
08/28/2020 Lot 37 Hawthorne Ridge Footing Inspection
08/28/2020 Lot 37 Hawthorne Ridge Wall inspection
08/31/2020 Letter INSPECTION SUMMARY
09/24/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter INSPECTION SUMMARY
12/22/2020 Letter INSPECTION SUMMARY
12/22/2020 Letter INSPECTION SUMMARY
12/23/2020 37 Hawthorne Ridge Floor Joists Holes Letter
12/23/2020 Letter INSPECTION SUMMARY
12/28/2020 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/22/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
03/04/2021 Letter INSPECTION SUMMARY
03/17/2021 Letter Codes Temporary Certificate of Occupancy
04/01/2021 Email RE External HT 37
04/01/2021 Letter Codes Temporary Certificate of Occupancy
04/19/2021 Letter Codes Temporary Certificate of Occupancy
04/19/2021 TCO Extension .msg
04/22/2021 Plot Plan Approved As Graded Plot Plan
04/23/2021 Letter INSPECTION SUMMARY
04/27/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter Field Certificate of Occupancy
06/07/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home