Permit Application Status

PRRES20202110


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202110
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - FINISHED BASEMENT
07/29/2020
08/03/2020
04/05/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/31/2020 07/31/2020
Dylan Eppert
Residential Plan Review Approved 07/31/2020 07/31/2020
Dylan Eppert
Planning Review (RES) Approved 08/03/2020 07/31/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $875.62 $875.62 Paid 08/03/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 08/03/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 08/03/2020
Water Meter Fee $455.54 $455.54 Paid 08/03/2020
Right of Way Permit Fee $80.00 $80.00 Paid 08/03/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/03/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/31/2020 8/31/2020 08/31/2020
Underslab Plumbing Inspection - Residential Passed 9/25/2020 9/25/2020 09/25/2020
Erosion Control Inspection Residential Failed 12/04/2020
Misc
Corrective Action Required
12/04/2020
-Erosion control requires continuous maintenance. Repair & re-establish methods within two business days -immediate street cleanup required -maintain gravel filter at driveway -no further inspections until complete
Electrical Service Inspection Passed 12/4/2020 12/4/2020 12/04/2020
Gas Piping Inspection - Residential Passed 12/4/2020 12/4/2020 12/04/2020
Gas Service Inspection - Residential Passed 12/4/2020 12/4/2020 12/04/2020
All Rough Inspection - Residential Failed 12/4/2020 12/4/2020 12/04/2020
Misc
Corrective Action Required
12/04/2020
-unable to verify fastening requirements of method PFH at portal frame, Two rows of 16D 3 inch on center at portal frame brace wall top plate -30 inch attic access head room required -6 inch edge 12 inch field exterior sheathing fastening -Maintain minimum air space clearance at B vent insulation shield -Inadequate Fireblock above fireplace -Fireblock penetrations in wood fire blocking made by other trades -Fireblock top plate penetrations in basement -Terminate lighting outlet in basement bedroom -Plan calls for three 2 x 10 floor joists located under header studs at cantilever, Southeast basement corner -Interior wall bracing per plan -Nail plate protection of electrical conductor main floor bedroom -Provide cripple studs above openings in non-bearing walls for proper gypsum attachment
All Rough Inspection - Residential Failed 12/9/2020 12/9/2020 12/09/2020
Misc
Corrective Action Required
12/09/2020
-Fireblock penetrations in wood fire blocking made by other trades -Fireblock top plate penetrations in basement -Terminate lighting outlet in basement bedroom
All Rough Inspection - Residential Passed 12/10/2020 12/10/2020 12/10/2020
Misc
Resolved
12/10/2020
Sewer Service Inspection - R Passed 1/20/2021 (8:30) 1/20/2021 01/20/2021
Water Service Inspection - R Passed 1/21/2021 (1:00) 1/21/2021 01/21/2021
Driveway Inspection Passed 1/29/2021 (P.M.) 1/29/2021 01/29/2021
Misc
Informational
01/29/2021
On Friday, 1-29-2021. I performed a drive approach inspection that passed city standards at the aforementioned location.
Occupancy Inspection - Codes Residential Failed 2/8/2021 2/8/2021 02/08/2021
Misc
Corrective Action Required
02/08/2021
-Complete final grade per approved plot plan and sod -Splash blocks at all sump pump and down spout locations, minimum 36” distance from foundation -Seal all penetrations in siding, seal along top of AC disconnect and meter can -Remove all construction debris from lot -Install range hood, exposed NM -No setback allowed with combustible material at living room floor receptacle -Flashing at front window trim
Occupancy Inspection - Codes Residential Temporary C of O 2/17/2021 2/17/2021 02/17/2021
Misc
Corrective Action Required
02/08/2021
-Complete final grade per approved plot plan and sod -Splash blocks at all sump pump and down spout locations, minimum 36” distance from foundation -Seal all penetrations in siding, seal along top of AC disconnect and meter can -Remove all construction debris from lot OK FOR TCO - TCO EXPIRES 3/17/21
Occupancy Inspection - Codes Residential Temporary C of O 03/16/2021
Misc
Corrective Action Required
02/17/2021
-Complete final grade per approved plot plan and sod -Splash blocks at all sump pump and down spout locations, minimum 36” distance from foundation -Seal all penetrations in siding, seal along top of AC disconnect and meter can -Remove all construction debris from lot -MAINTAIN EROSION CONTROL SILT FENCE ON LOT UNTIL SOD IS PLACED. CLEAN ALL MUD FROM STREET. OK FOR TCO - TCO EXPIRATION EXTENDED - EXPIRES 3/30/21
Erosion Control Inspection Residential Failed 03/16/2021
Misc
Corrective Action Required
12/04/2020
-MAINTAIN EROSION CONTROL SILT FENCE ON LOT UNTIL SOD IS PLACED. CLEAN ALL MUD FROM STREET.
Plot Plan Inspection Passed 4/1/2021 4/1/2021 04/01/2021
Occupancy Inspection - Codes Residential Failed 4/1/2021 4/1/2021 04/01/2021
Misc
Corrective Action Required
03/16/2021
-OBTAIN LAWN IRRIGATION SYSTEM PERMIT -WATER METER LID TO BE EVEN WITH GRADE, MAINTAIN REQUIRED 14"-18" CLEARANCE FROM TOP OF METER TO TOP OF LID
Occupancy Inspection - Codes Residential Full C of O 4/5/2021 4/5/2021 04/05/2021
Misc
Resolved
04/05/2021
Documents & Images
Date Uploaded File Type Document Name
07/29/2020 Application Form H4 #52 - PERMIT APP
07/29/2020 52 HAWTHORNE RIDGE ROOF LAYOUT- signed
07/29/2020 H4 #52 - Charlotte - Craftsman - Sheets- signed
07/29/2020 400417
07/29/2020 LOT 52 FINAL
07/31/2020 Drawing APPROVED TRUSS LAYOUT
07/31/2020 Specifications APPROVED TRUSS PACKAGE
07/31/2020 Plans APPROVED HOUSE AND ELEVATIONS
07/31/2020 Plot Plan APPROVED PLOT PLAN
08/03/2020 Receipt Receipt for transaction:2020-004912
08/03/2020 Letter DS Building Permit
08/28/2020 Lot 52 Hawthorn Ridge footing Inspection
08/31/2020 Letter INSPECTION SUMMARY
09/01/2020 Lot 52 Hawthorne Ridge Wall Inspection
09/25/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/09/2020 Seal penetrations basement.jpg
12/09/2020 Basement top plate penetrations .jpg
12/09/2020 Letter INSPECTION SUMMARY
12/10/2020 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
02/08/2021 Letter INSPECTION SUMMARY
02/17/2021 Letter Codes Temporary Certificate of Occupancy
03/16/2021 Letter Codes Temporary Certificate of Occupancy
03/16/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
04/05/2021 Letter Field Certificate of Occupancy
04/05/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home