Summary
PRRES20201862
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT STOP WORK ORDER generated on 01/26/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 02/24/2021 12:00 AM by username 'Patrick Schonfeldt'.
07/08/2020
08/04/2020
01/20/2022
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/20/2020 08/04/2020
Steve Conrick
Drainage swales
Corrective Action Required
07/20/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provided. 2 swales. one is an ovewr flow swale called out on mdp
Spot elevations
Corrective Action Required
07/20/2020

CROSS SECTION ELEVATIONS OF SWALES
Basement opening elevations
Corrective Action Required
07/20/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
As-graded plot plan
Corrective Action Required
07/20/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
MISSING OVERFLOW SWALE Steven Conrick 07/16/2020 4:01 PM
Residential Plan Review Approved 08/06/2020 08/04/2020
Steve Conrick
pending planning review Steven Conrick 07/30/2020 3:37 PM
Planning Review (RES) Approved 07/21/2020 08/04/2020
Jennifer Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,299.80 $1,299.80 Paid 08/04/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/04/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/04/2020
8331504-EFHB Middle Big Creek, Full $602.64 $602.64 Paid 08/04/2020
8331507-Sewer Connection Fee $540.00 $540.00 Paid 08/04/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/04/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 08/04/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/22/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 07/22/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 07/22/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/17/2020 (1:00) 8/17/2020 08/17/2020
Underslab Plumbing Inspection - Residential Passed 9/18/2020 9/18/2020 09/18/2020
Electrical Service Inspection Passed 12/10/2020 12/10/2020 12/10/2020
Gas Piping Inspection - Residential Failed 12/10/2020 12/10/2020 12/10/2020
Misc
Corrective Action Required
12/10/2020
- COMPLETE GAS LINE INSTALLATION AT FIREPLACE
Gas Service Inspection - Residential Failed 12/10/2020 12/10/2020 12/10/2020
Misc
Corrective Action Required
12/10/2020
- COMPLETE GAS LINE INSTALL AT FIREPLACE - PRESSURE TEST AFTER FIREPLACE GAS LINE INSTALL COMPLETE
All Rough Inspection - Residential Failed 12/10/2020 12/10/2020 12/10/2020
Misc
Corrective Action Required
12/10/2020
-Joist hanger at tail joist to attic access connect, over 4’, garage -Anchor bolt required within 12” of plate break in garage -Floor joist bored for NM/low volt less than 2” from end of joist, garage -Structural straps at all top plates on all exterior walls and interior load bearing walls bored 50% or more -Secure all DWV 2” or less at mid point -Shield pex from recessed can lights, less than 6” distance, 1st floor above kitchen -security blocking at doors -Floor joists bores for NM less than 2” from end of joist, (2) bores less than 2” apart, 1st floor kitchen above patio door, 1st floor bath -Complete gas fireplace install -Attach bath exhaust fan discharge with metallic tape, not electrical tape -Protection plates are top and bottom plates, NM home run 1st and 2nd floor -2nd floor E bathroom deadspace cavity too large for loose insulation fireblock -Joist hanger at 2nd floor hall ceiling joist, over 4’ -Joist hangers at ceiling joist to dbl lvl connection outside 2nd floor bedroom hall -Strap top plates at plate breaks 1st and 2nd floor -Attic access required 2nd floor -Land NM for kitchen island, seal floor penetrations, protect 6” AFF, romex bundled up in basement -Hardwire furnace
Sewer Service Inspection - R Not Ready 12/29/2020 (10:00) 12/29/2020 12/29/2020
Misc
Corrective Action Required
12/29/2020
NOT READY FOR INSPECTION -SEWER LINE NOT INSTALLED, CONTRACTOR NOT ON SITE
All Rough Inspection - Residential Failed 12/29/2020 12/29/2020 12/29/2020
Misc
Corrective Action Required
12/29/2020
-Joist hanger at tail joist to attic access connect, over 4’, garage -Anchor bolt required within 12” of plate break in garage -Structural straps at all top plates on all exterior walls and interior load bearing walls bored 50% or more -security blocking at doors -Attach bath exhaust fan discharge with metallic tape, not electrical tape -Protection plates are top and bottom plates, NM home run 2nd floor -2nd floor E bathroom deadspace cavity too large for loose insulation fireblock -Joist hanger at 2nd floor hall ceiling joist, over 4’ -Joist hangers at ceiling joist to dbl lvl connection outside 2nd floor bedroom hall -Strap top plates at plate breaks 1st and 2nd floor -Attic access required 2nd floor -Land NM for kitchen island, seal floor penetrations, protect 6” AFF, romex bundled up in basement -Secure ward flex gas line at fireplace -Where bores in joists for NM less than 2” from end of joist have been addressed by engineer, protection plates are required at all locations where 1 1/4” or less from end of joist
Gas Piping Inspection - Residential Failed 12/29/2020 12/29/2020
Misc
Corrective Action Required
12/10/2020
- SECURE WARD FLEX LINE AT FIREPLACE
Gas Service Inspection - Residential Failed 12/29/2020 12/29/2020 12/29/2020
Misc
Corrective Action Required
12/10/2020
-SECURE WARD FLEX GAS LINE AT FIREPLACE -GAS PRESSURE TEST REQUIRED
Sewer Service Inspection - R Not Ready 1/8/2021 (3:00) 1/8/2021 01/08/2021
Misc
Corrective Action Required
12/29/2020
NOT READY FOR INSPECTION -SEWER LINE NOT INSTALLED, SEVERAL EROSION CONTROL ISSUES, SEE EROSION CONTROL REPORT
Erosion Control Inspection Residential Failed 1/8/2021 1/8/2021 01/08/2021
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/08/2021
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. -SILT FENCE REQUIRED AT FRONT OF LOT -STREET CLEANUP REQUIRED IMMEDIATELY AT MUD AND SILT IN STREET -PLUMBING CONTRACTOR DISCHARGING WATER FROM TRENCH INTO CITY STORM INLET, NOT ALLOWED, CLEANUP SILT FROM DISCHARGE ALONG STREET
Erosion Control Inspection Residential Failed 1/25/2021 1/25/2021 01/25/2021
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/08/2021
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. -SILT FENCE REQUIRED AT FRONT OF LOT -STREET CLEANUP REQUIRED IMMEDIATELY AT MUD AND SILT IN STREET -INSTALL BARRIER FENCE AT TRENCH ADDRESS ISSUES WITHIN 24 HOURS
Erosion Control Inspection Residential Failed - Stop Work 1/26/2021 1/26/2021 01/26/2021
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/25/2021
1/8/21 - REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. -SILT FENCE REQUIRED AT FRONT OF LOT -STREET CLEANUP REQUIRED IMMEDIATELY AT MUD AND SILT IN STREET -INSTALL BARRIER FENCE AT TRENCH 1/25/21 - DISCUSSED ISSUES WITH CONTRACTOR AND ALLOWED 24 HOURS FOR CORRECTION 1/26/21 - STOP WORK ISSUED, ISSUES REMAIN, EROSION CONTROL SILT FENCE REQUIRED, STORM INLET PROTECTION REQUIRED, CLEAN MUD AND GRAVEL FROM STREET, SAFETY BARRIER AT OPEN TRENCH. NO ADDITIONAL WORK HAS TAKEN PLACE ON SEWER TRENCH SINCE 1/8/21 INSPECTION
Sewer Service Inspection - R Passed 2/24/2021 (10:45) 2/24/2021 02/24/2021
Misc
Resolved
02/24/2021
Erosion Control Inspection Residential Failed 2/24/2021 2/24/2021 02/24/2021
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
02/24/2021
1/8/21 - REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. -SILT FENCE REQUIRED AT FRONT OF LOT -STREET CLEANUP REQUIRED IMMEDIATELY AT MUD AND SILT IN STREET -INSTALL BARRIER FENCE AT TRENCH 1/25/21 - DISCUSSED ISSUES WITH CONTRACTOR AND ALLOWED 24 HOURS FOR CORRECTION 1/26/21 - STOP WORK ISSUED, ISSUES REMAIN, EROSION CONTROL SILT FENCE REQUIRED, STORM INLET PROTECTION REQUIRED, CLEAN MUD AND GRAVEL FROM STREET, SAFETY BARRIER AT OPEN TRENCH. NO ADDITIONAL WORK HAS TAKEN PLACE ON SEWER TRENCH SINCE 1/8/21 INSPECTION
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/24/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -SILT FENCE REQUIRED AT FRONT OF LOT- -CLEAN ALL MUD AND GRAVEL FROM STREET
Water Service Inspection - R Passed 2/25/2021 (9:45) 2/25/2021 02/25/2021
All Rough Inspection - Residential Passed 3/2/2021 3/2/2021 03/02/2021
Misc
Resolved
03/02/2021
Gas Piping Inspection - Residential Passed 3/2/2021 3/2/2021 03/02/2021
Misc
Resolved
03/02/2021
- SECURE WARD FLEX LINE AT FIREPLACE
Gas Service Inspection - Residential Passed 3/2/2021 3/2/2021 03/02/2021
Misc
Resolved
03/02/2021
-SECURE WARD FLEX GAS LINE AT FIREPLACE -GAS PRESSURE TEST REQUIRED
Driveway Inspection Passed 4/19/2021 4/21/2021 04/22/2021
Occupancy Inspection - Codes Residential Failed 7/21/2021 7/21/2021 07/21/2021
Misc
Corrective Action Required
07/21/2021
-Resolve outstanding inspection fee(s) before final c of o -Submit as graded plot plan for review and approval -lawn irrigation permit -GFCI protection on dishwasher receptacle -splash blocks -gutters and downspouts -secure ac electrical whip within 12” of disconnect and secure whip up off grade -stairs at rear sliding door
Occupancy Inspection - Codes Residential Temporary C of O 7/22/2021 7/22/2021 07/22/2021
Misc
Corrective Action Required
07/21/2021
-Submit as graded plot plan for review and approval -splash blocks -gutters and downspouts OK FOR TCO - TCO EXPIRES 8/12/21
Erosion Control Inspection Residential Passed 1/20/2022 1/20/2022 01/20/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/20/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -SILT FENCE REQUIRED AT FRONT OF LOT- -CLEAN ALL MUD AND GRAVEL FROM STREET
Plot Plan Inspection Passed 1/20/2022 01/20/2022
Occupancy Inspection - Codes Residential Full C of O 1/20/2022 1/20/2022 01/20/2022
Misc
Resolved
01/20/2022
-Submit as graded plot plan for review and approval -splash blocks -gutters and downspouts OK FOR TCO - TCO EXPIRES 8/12/21
Documents & Images
Date Uploaded File Type Document Name
07/08/2020 Copy of Lees Summit Residental Permit Application 1812 sw blackstone
07/08/2020 License_Tax_Application 1812 blackstone
07/13/2020 1812 sw blackstone stamped plan
07/15/2020 LOT 97 FINAL
08/03/2020 Letter Codes Residential Plan Review
08/04/2020 APPROVED LOT 97 CITY
08/04/2020 APPROVED 1812 sw blackstone stamped plan
08/04/2020 napa valley approved ELEVATIONS
08/04/2020 Receipt Receipt for transaction:2020-004960
08/04/2020 Letter DS Building Permit
08/17/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
12/10/2020 Letter INSPECTION SUMMARY
12/10/2020 Letter INSPECTION SUMMARY
12/10/2020 Letter INSPECTION SUMMARY
12/10/2020 Letter INSPECTION SUMMARY
12/22/2020 4030 Benziger & 1812 Blackstone
12/29/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
12/29/2020 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/08/2021 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter Stop Work Order
01/26/2021 EE60D88C-EFE7-4C1E-B5EC-5A8DEE56A316.jpeg
01/26/2021 421F4CF6-2317-47AF-963A-FEB9A75DDA6B.jpeg
02/24/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
02/25/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
04/22/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
07/22/2021 Receipt Receipt for transaction:2021-005861
07/22/2021 Letter Codes Temporary Certificate of Occupancy
01/19/2022 Plot Plan APPROVED AS BUILT PLOT PLAN
01/20/2022 Letter INSPECTION SUMMARY
01/20/2022 Letter INSPECTION SUMMARY
01/20/2022 Letter Field Certificate of Occupancy
01/20/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents