Permit Application Status

PRRES20201756


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201756
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ROOF TRUSS
06/29/2020
07/07/2020
03/05/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/01/2020 07/07/2020
Dylan Eppert
Drainage swales
Corrective Action Required
07/01/2020

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide
As-graded plot plan
Corrective Action Required
07/01/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Planning Review (RES) Approved 07/06/2020 07/01/2020
Dylan Eppert
Residential Plan Review Approved 07/01/2020 07/01/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,280.75 $1,280.75 Paid 07/07/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 07/07/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 07/07/2020
Water Meter Fee $455.54 $455.54 Paid 07/07/2020
Right of Way Permit Fee $80.00 $80.00 Paid 07/07/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/07/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/16/2020 7/16/2020 07/16/2020
Underslab Plumbing Inspection - Residential Passed 8/6/2020 8/6/2020 08/06/2020
Sewer Service Inspection - R Passed 8/25/2020 (10:30) 8/25/2020 08/25/2020
Water Service Inspection - R Passed 8/27/2020 (1:00) 8/27/2020 08/27/2020
All Rough Inspection - Residential Failed 10/23/2020 10/23/2020 10/23/2020
Misc
Corrective Action Required
10/23/2020
-proper Fireblock between floor levels, furr out framing and all top and bottom plate penetrations -flash siding splices -12” OC fastening stud to stud and abutting studs at intersecting braced walls -Structural straps required at all over bored interior loadbearing walls, straps required to span 6 inches on either side of penetration with minimum of four 10d nails each side -Fireblock concealed space upstairs bedroom closet -Braced wall method at dining room windows per plan, BWL-1 -Braced wall method at great room windows per plan -horizontal blocking shall be placed between studs at the door lock height for 3 stud spaces or equivalent bracing on each side of exterior door openings -Four bearing 2x4 right side patio slider per plan -Install all interior wall bracing per plan -Plan calls double every other 2 x 10 from master bedroom steel beam to garage/dwelling separation wall -four 2x4 under LVL spanning flex room -2x4’s under lvl spanning foyer per plan -Anchor steel columns -two 2x4 under GT bearing point at garage/dwelling separation wall -washers & nuts at anchor bolts in garage -Flash exterior windows -6” OC edge and 12” OC field exterior sheathing fastening -Plumbing vent termination prohibited within 10’ of openable window unless 3’ above opening -Repair damaged areas of vapor barrier -Replace damaged sheets of siding -three 2x4 under lvl garage/dwelling wall -Address over Notched & in middle 1/3 double 2 x 10 in garage -Grout between garage door tremors and foundation
Gas Piping Inspection - Residential Passed 10/23/2020 10/23/2020 10/23/2020
Electrical Service Inspection Passed 10/23/2020
Gas Service Inspection - Residential Passed 10/23/2020 10/23/2020 10/23/2020
All Rough Inspection - Residential Failed 10/28/2020 10/28/2020 10/28/2020
Misc
Corrective Action Required
10/23/2020
-flash siding splices -horizontal blocking shall be placed between studs at the door lock height for 3 stud spaces or equivalent bracing on each side of exterior door openings -Install all interior wall bracing per plan -LIB 2nd floor -Plan calls double every other 2 x 10 from master bedroom steel beam to garage/dwelling separation wall -Flash exterior windows -6” OC edge and 12” OC field exterior sheathing fastening -Plumbing vent termination prohibited within 10’ of openable window unless 3’ above opening -Repair damaged areas of vapor barrier -Replace damaged sheets of siding -three 2x4 under lvl garage/dwelling wall OK TO INSULATE, REMOVE ANY INSULATION FROM INSPECTION ITEMS
All Rough Inspection - Residential Failed 10/29/2020 10/29/2020 10/29/2020
Misc
Corrective Action Required
10/28/2020
-horizontal blocking shall be placed between studs at the door lock height for 3 stud spaces or equivalent bracing on each side of exterior door openings - security blocking back door -Plan calls double every other 2 x 10 from master bedroom steel beam to garage/dwelling separation wall -Flash exterior windows -6” OC edge and 12” OC field exterior sheathing fastening OK TO INSULATE, REMOVE ANY INSULATION FROM INSPECTION ITEMS
All Rough Inspection - Residential Passed 10/30/2020 10/30/2020 10/30/2020
Misc
Resolved
10/30/2020
Driveway Inspection Passed 11/5/2020 (P.M.) 11/5/2020 11/06/2020
Misc
Informational
11/06/2020
On Thursday, 11-05-2020. The contractor formed, graded and poured City Driveway. Drive passed inspection.
Sidewalk Inspection Passed 11/5/2020 (P.M.) 11/5/2020 11/06/2020
Misc
Informational
11/06/2020
On Thursday, 11-05-2020. The contractor formed and graded city sidewalk. Sidewalk passed field inspection.
Occupancy Inspection - Codes Residential Failed 1/5/2021 1/5/2021 01/05/2021
Misc
Corrective Action Required
01/05/2021
-Submit as graded plot plan for review -Complete final grade and sod -splash blocks at all downspout and sump pump discharge locations, minimum 36” distance from foundation -Light fixtures at back patio must be sealed tamper resistant type, less than 8’ from walking surface -Install handle/lock sliding patio door -two locking devices required at sliding patio door -Install master tub -Kitchen faucet/disposal required -2nd floor attic access
Plot Plan Inspection Failed 1/20/2021 01/20/2021
Misc
Corrective Action Required
01/20/2021
-SWALE REQUIRED AT BACK OF LOT AS SHOWN ON PLOT PLAN
Occupancy Inspection - Codes Residential Temporary C of O 1/20/2021 1/20/2021 01/20/2021
Misc
Corrective Action Required
01/05/2021
-SOD -SEE PLOT PLAN INSPECTION REPORT - SWALE REQUIRED AT BACK OF LOT AS SHOWN ON PLOT PLAN OK FOR TCO - TCO EXPIRES 2/17/21
Occupancy Inspection - Codes Residential Temporary C of O 1/25/2021 2/9/2021 02/09/2021
Misc
Corrective Action Required
01/20/2021
-SOD -SEE PLOT PLAN INSPECTION REPORT - SWALE REQUIRED AT BACK OF LOT AS SHOWN ON PLOT PLAN OK FOR TCO - TCO EXTENSION - EXPIRES 3-8-21
Occupancy Inspection - Codes Residential Failed 3/3/2021 3/3/2021 03/03/2021
Misc
Corrective Action Required
02/09/2021
-SEE PLOT PLAN INSPECTION REPORT - SWALE REQUIRED AT BACK OF LOT AS SHOWN ON PLOT PLAN OK FOR TCO - TCO EXTENSION - EXPIRES 3-8-21
Plot Plan Inspection Passed 03/05/2021
Misc
Resolved
03/05/2021
-SWALE REQUIRED AT BACK OF LOT AS SHOWN ON PLOT PLAN
Occupancy Inspection - Codes Residential Full C of O 3/5/2021 3/5/2021 03/05/2021
Misc
Resolved
03/05/2021
-SEE PLOT PLAN INSPECTION REPORT - SWALE REQUIRED AT BACK OF LOT AS SHOWN ON PLOT PLAN OK FOR TCO - TCO EXTENSION - EXPIRES 3-8-21
Documents & Images
Date Uploaded File Type Document Name
06/29/2020 HT #22 - PERMIT APP
06/29/2020 LOT 22 FINAL
06/29/2020 HT #22 - Valentia - Craftsman - Sheets- signed
06/29/2020 400360
06/29/2020 22 HAWTHORNE RIDGE TRUSS LAYOUT
07/01/2020 Plans APPROVED HOUSE PLANS
07/01/2020 Specifications APPROVED SPEC SHEETS
07/01/2020 Drawing APPROVED TRUSS LAYOUT
07/01/2020 Letter Codes Residential Plan Review
07/01/2020 APPROVED ELEVATIONS
07/07/2020 Plot Plan APPROVED PLOT PLAN
07/07/2020 Receipt Receipt for transaction:2020-004152
07/07/2020 Letter DS Building Permit
07/15/2020 Lot 22 Hawthorne Ridge - Footing Inspection
07/16/2020 Letter INSPECTION SUMMARY
08/03/2020 Lot 22 Hawthorne Ridge -Wall Inspection
08/06/2020 Letter INSPECTION SUMMARY
08/25/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
10/28/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter INSPECTION SUMMARY
10/30/2020 Letter INSPECTION SUMMARY
01/05/2021 Letter INSPECTION SUMMARY
01/19/2021 Plot Plan APPROVED AS BUILT
01/20/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter Codes Temporary Certificate of Occupancy
02/09/2021 Letter Codes Temporary Certificate of Occupancy
02/09/2021 Email 1521 SW SUGAR TREE DR LEES SUMMIT MO 64082
03/03/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter Field Certificate of Occupancy
03/05/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home