Permit Application Status

PRRES20201531


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201531
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY PARTIALLY FINISHED BASEMENT COVERED DECK
06/08/2020
06/12/2020
05/06/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/11/2020 06/11/2020
Steve Conrick
Residential Plan Review Approved 06/11/2020 06/11/2020
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $990.10 $990.10 Paid 06/12/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/12/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/12/2020
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 06/12/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 06/12/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 06/12/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 06/12/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 05/05/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 07/23/2020
Misc
Corrective Action Required
07/23/2020
- Footing poured without inspection, submit 3rd party inspection report
Footing Inspection - Residential Passed 7/30/2020 7/30/2020 07/30/2020
Misc
Resolved
07/30/2020
Underslab Plumbing Inspection - Residential Not Ready 8/14/2020 8/14/2020 08/14/2020
Misc
Corrective Action Required
08/14/2020
NOT READY FOR INSPECTION, NO INSPECTION PERFORMED DWV FOR UNDERSLAB HAS NOT BEEN INSTALLED
Underslab Plumbing Inspection - Residential Failed 8/25/2020 8/25/2020 08/25/2020
Misc
Corrective Action Required
08/14/2020
- INTERIOR DRAIN TILE NEEDS TO REACH OPPOSITE END OF FOUNDATION FROM SUMP PIT WHEN LAYING INTERIOR DRAIN TILE DIAGONALLY
Underslab Plumbing Inspection - Residential Passed 9/14/2020 9/14/2020 09/14/2020
Misc
Resolved
09/14/2020
Gas Piping Inspection - Residential Failed 12/4/2020 12/4/2020 12/04/2020
Misc
Corrective Action Required
12/04/2020
- SECURE GAS FLEX LINE AT FIREPLACE
Electrical Service Inspection Passed 12/4/2020 12/4/2020 12/04/2020
Gas Service Inspection - Residential Failed 12/4/2020 12/4/2020 12/04/2020
Misc
Corrective Action Required
12/04/2020
- SECURE GAS FLEX LINE AT FIREPLACE - GAS PRESSURE GAUGE AT 0, MUST MAINTAIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Failed 12/4/2020 12/4/2020 12/04/2020
Misc
Corrective Action Required
12/04/2020
-Missing nuts on anchor bolts in garage -Anchor bolts required within 12” of plate break in garage -sheathing missing N garage wall at sgl car garage -Seal all top plate penetrations -Box out for chase at b vent in garage -Pan off cantilever in garage -(2) studs bearing at end for dbl truss girder in garage and front bed -Fireblock deadspace/archway at garage entry/dining -secure flex gas line at fireplace -EC#2 per plans -H2.5 straps at all truss ends at front porch -Truss hangers per plans -Complete all furred downs and chases in basement -Fireblock between top plate and framing in basement, seal all gaps and penetrations in Fireblock -Fireblock vertical every 10’ between framing/foundation in basement, seal all gaps and penetrations in Fireblock -Bocca protection plates at DWV wet bar basement -Bolt outer ply of rim to ledger at deck -Provide (2) bolts per post/rim connection at deck
Sewer Service Inspection - R Passed 12/9/2020 (1:45) 12/9/2020 12/09/2020
Water Service Inspection - R Partial 12/10/2020 12/10/2020 12/10/2020
Misc
Informational
12/10/2020
-PARTIAL INSPECTION ON PEX FROM MID POINT FRONT YARD TO HOUSE ENTRANCE, OK TO COVER PORTION INSPECTED
Gas Piping Inspection - Residential Passed 12/11/2020 12/11/2020 12/11/2020
Misc
Resolved
12/11/2020
Gas Service Inspection - Residential Failed 12/11/2020 12/11/2020 12/11/2020
Misc
Corrective Action Required
12/04/2020
- GAS PRESSURE GAUGE AT 0, MUST MAINTAIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Failed 12/11/2020 12/11/2020 12/11/2020
Misc
Corrective Action Required
12/11/2020
-Truss hangers per plans-garage -Terminate and secure NM at basement bed hall ceiling -protection plate at top plate furred down, basement bed closet -Fireblock between top plate and framing in basement, seal all gaps and penetrations in Fireblock -Fireblock vertical every 10’ between framing/foundation in basement, seal all gaps and penetrations in Fireblock -Bocca protection plates at DWV wet bar basement
Water Service Inspection - R Passed 12/14/2020 12/14/2020 12/14/2020
Misc
Resolved
12/14/2020
-PARTIAL INSPECTION ON PEX FROM MID POINT FRONT YARD TO HOUSE ENTRANCE, OK TO COVER PORTION INSPECTED
Gas Service Inspection - Residential Passed 12/15/2020 12/15/2020 12/15/2020
Misc
Resolved
12/15/2020
All Rough Inspection - Residential Passed 12/15/2020 12/15/2020 12/15/2020
Misc
Resolved
12/15/2020
Sidewalk Inspection Partial 1/11/2021 (P.M.) 1/11/2021 01/11/2021
Misc
Informational
01/11/2021
1-11-21 11:31am The sidewalk forms are set and are ADA compliant at this time. They have plenty of aggregate. They have been informed to use white cure evenly and a broom finish.
Driveway Inspection Partial 1/11/2021 1/11/2021 01/11/2021
Misc
Informational
01/11/2021
1-11-21 11:33am The forms are set and they know to stay ADA compliant through the driveway for the sidewalk. Aggregate is compacted.
Sidewalk Inspection Partial 01/11/2021
Misc
Informational
01/11/2021
1-11-21 11:31am The sidewalk forms are set and are ADA compliant at this time. They have plenty of aggregate. They have been informed to use white cure evenly and a broom finish. They have been informed to cover with blankets due to weather.
Driveway Inspection Partial 01/11/2021
Misc
Informational
01/11/2021
1-11-21 11:33am The forms are set and they know to stay ADA compliant through the driveway for the sidewalk. Aggregate is compacted. They have been informed to cover with blankets due to temps dropping below freezing.
Sidewalk Inspection Passed 1/18/2021 1/18/2021 01/20/2021
Misc
Informational
01/11/2021
1-11-21 11:31am The sidewalk forms are set and are ADA compliant at this time. They have plenty of aggregate. They have been informed to use white cure evenly and a broom finish. They have been informed to cover with blankets due to weather.
Driveway Inspection Passed 1/18/2021 1/18/2021 01/21/2021
Misc
Informational
01/11/2021
1-11-21 11:33am The forms are set and they know to stay ADA compliant through the driveway for the sidewalk. Aggregate is compacted. They have been informed to cover with blankets due to temps dropping below freezing.
Miscellaneous Inspection Failed 1/21/2021 1/21/2021 01/21/2021
Misc
Informational
01/21/2021
JOHN DIMAURO 1/21/2021 THE SS MANHOLE AT THE REAR OF THE PROPERTY (SOUTHEAST CORNER) APPEARS TO BE SET TO HIGH. THE MH IS APPROXIMATELY 4’ FT FROM THE SIDEWALK AND APPROXIMATELY 20” IN HIGHER THAN THE SIDEWALK. THE SIDEWALK APPEARS TO BE SET AT THE CORRECT ELEVATION.
Occupancy Inspection - Codes Residential Failed 3/9/2021 3/9/2021 03/09/2021
Misc
Corrective Action Required
03/09/2021
-Resolve outstanding inspection fee(s) before final c of o -Final grade -Sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36" distance from foundation -Seal all penetrations in siding, seal along top of meter can and AC disconnect -Guardrail required at front porch, more than 30” from grade -Gutters and downpouts required -Handrail required at garage stairs, 4 rises -Non combustible attic access cover required at garage -AFCI required at washer circuit -Install built in oven at kitchen -(2) bolts at each post/beam connection per code **SEE FIELD ENGINEER NOTES BELOW FROM 1/21/21** "THE SS MANHOLE AT THE REAR OF THE PROPERTY (SOUTHEAST CORNER) APPEARS TO BE SET TO HIGH. THE MH IS APPROXIMATELY 4’ FT FROM THE SIDEWALK AND APPROXIMATELY 20” IN HIGHER THAN THE SIDEWALK. THE SIDEWALK APPEARS TO BE SET AT THE CORRECT ELEVATION."
Occupancy Inspection - Codes Residential Failed 4/29/2021 4/29/2021 04/29/2021
Misc
Corrective Action Required
03/09/2021
-Resolve outstanding inspection fee(s) before final c of o -Guardrail required at front porch, more than 30” from grade -Handrail required at garage stairs, 4 rises -Non combustible attic access cover required at garage -AFCI required at washer circuit -(2) through bolts at each post/beam connection per code **SEE FIELD ENGINEER NOTES BELOW FROM 1/21/21** "THE SS MANHOLE AT THE REAR OF THE PROPERTY (SOUTHEAST CORNER) APPEARS TO BE SET TO HIGH. THE MH IS APPROXIMATELY 4’ FT FROM THE SIDEWALK AND APPROXIMATELY 20” IN HIGHER THAN THE SIDEWALK. THE SIDEWALK APPEARS TO BE SET AT THE CORRECT ELEVATION."
Plot Plan Inspection Passed 05/06/2021
Occupancy Inspection - Codes Residential Full C of O 5/6/2021 5/6/2021 05/06/2021
Misc
Resolved
05/06/2021
Documents & Images
Date Uploaded File Type Document Name
06/08/2020 RR #91 - PERMIT APPLICATION
06/09/2020 91 Reserve at Stoney Creek Roof Layout
06/09/2020 400307
06/09/2020 RR #91 - Juliette - Mediterranean - Sheets
06/09/2020 LOT 91 FINAL
06/11/2020 APPROVED 91 Reserve at Stoney Creek Roof Layout
06/11/2020 APPROVED 400307
06/11/2020 APPROVED RR #91 - Juliette - Mediterranean - Sheets
06/11/2020 APPROVED LOT 91 FINAL
06/12/2020 Receipt Receipt for transaction:2020-003037
06/12/2020 Letter DS Building Permit
07/23/2020 Letter INSPECTION SUMMARY
07/30/2020 Lot 91 Reserve at Stoney Creek Footing Inspection
07/30/2020 Lot 91 Reserve at Stoney Creek Wall Inspection
07/30/2020 Letter INSPECTION SUMMARY
08/14/2020 Letter INSPECTION SUMMARY
08/25/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter INSPECTION SUMMARY
12/10/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
01/11/2021 Letter INSPECTION SUMMARY
01/11/2021 Letter INSPECTION SUMMARY
01/11/2021 Letter INSPECTION SUMMARY
01/11/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/21/2021 Letter INSPECTION SUMMARY
01/21/2021 SS MH SET HIGH.jpg
01/21/2021 Letter INSPECTION SUMMARY
03/09/2021 Letter INSPECTION SUMMARY
04/29/2021 Letter INSPECTION SUMMARY
05/05/2021 Receipt Receipt for transaction:2021-002521
05/06/2021 Letter INSPECTION SUMMARY
05/06/2021 Letter Field Certificate of Occupancy
05/06/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home