Permit Application Status

PRRES20201451


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201451
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS PACKAGE - COVERED DECK - UNFINISHED BASEMENT
06/03/2020
06/05/2020
01/26/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/05/2020 06/05/2020
Dylan Eppert
As-graded plot plan
Corrective Action Required
06/05/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 06/05/2020 06/05/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,280.55 $1,280.55 Paid 06/05/2020
8331507-Sewer Connection Fee $570.00 $570.00 Paid 06/05/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 06/05/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 06/05/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/05/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/05/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/23/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/23/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 6/24/2020 06/24/2020
Misc
Corrective Action Required
06/24/2020
- Footing poured without inspection. Submit engineer inspection report within 48 hours per ordinance-
Footing Inspection - Residential Passed 6/26/2020 07/02/2020
Misc
Resolved
07/02/2020
- Footing poured without inspection. Submit engineer inspection report within 48 hours per ordinance-
Underslab Plumbing Inspection - Residential Not Ready 7/17/2020 7/17/2020 07/17/2020
Misc
Corrective Action Required
07/17/2020
NO INSPECTION PERFORMED - POST ADDRESS -
Underslab Plumbing Inspection - Residential Passed 7/22/2020 7/22/2020 07/22/2020
Misc
Resolved
07/22/2020
All Rough Inspection - Residential Failed 10/7/2020 10/7/2020 10/07/2020
Misc
Corrective Action Required
10/07/2020
-method PFH nailing 3” oc grid at double car garage, Missing interior tension strap and tighten anchor bolts -Grout between garage door trimmers and foundation -Flash above trim at garage doors -Repair damage sections of exterior vapor barrier -Exterior sheathing to be fastened 6” oc edges & 12” field -Fireplace gas vent required to be 2 feet higher than any portion of the building within 10 feet due to vertical wall within 8 feet of termination -Plumbing vent cannot terminate within 10’ horizontal of window unless it is 3’ above the window opening -Deck ledger attachment per code -Deck post to peer connection -Nail joist hanger above entry -Structural strap required at over bored load bearing top plate penetration -Proper nail plate protection at plumbing top plate penetration, 2” below top plate -midpoint support for all vertical 2 inch and smaller DWV -LVL header dining room windows continuous corner to corner per plan -LVL header great room windows continuous corner to corner per plan -Complete all interior wall bracing per plan -Ensure all top and bottom plate penetrations are fire blocked -Fire block horizontal to vertical at wall/soffit connection, Master bedroom -Address hole bored in 2” DWV piping in garage plumbing/mechanical furr out -Fire block garage plumbing/mechanical furr out at horizontal to vertical -Missing truss connector in garage -Where cable is run at angles with joists in unfinished basements it shall be permissible to secure cables not smaller than two 6 AWG or three 8 AWG conductors directly to the lower edges of the joists. Smaller cables shall be run either through bored holes in joists or on running boards. -Anchor steel columns in basement -2 x 10 header over basement egress window per plan -Continue solid blocking under kitchen island, over beams and where joist run parallel to foundation -Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 12” oc nailing -backfill excavated area at foundation
Gas Service Inspection - Residential Failed 10/7/2020 10/7/2020 10/07/2020
Misc
Corrective Action Required
10/07/2020
Connect piping to gas fireplace per manufacturers installation instructions
Electrical Service Inspection Passed 10/7/2020 10/7/2020 10/07/2020
Gas Piping Inspection - Residential Failed 10/7/2020 10/7/2020 10/07/2020
Misc
Corrective Action Required
10/07/2020
Connect piping to gas fireplace per installation instructions
Erosion Control Inspection Residential Failed 10/12/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/12/2020
10-12-20 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Failed 10/14/2020 10/14/2020 10/14/2020
Misc
Corrective Action Required
10/07/2020
-Repair damage sections of exterior vapor barrier -Exterior sheathing to be fastened 6” oc edges & 12” field -Fireplace gas vent required to be 2 feet higher than any portion of the building within 10 feet due to vertical wall within 8 feet of termination - G2427.6.4 -Structural strap required at over bored load bearing top plate penetration- all interior load bearing walls and all exterior walls -Ensure all top and bottom plate penetrations are fire blocked and sealed -Missing truss connector in garage
All Rough Inspection - Residential Failed 10/20/2020 10/20/2020 10/20/2020
Misc
Corrective Action Required
10/14/2020
-Ensure all top and bottom plate penetrations are fire blocked and sealed -Missing truss connector in garage -D5 hangers HOUSE INSULATED WITHOUT APPROVAL - REMOVE INSULATION FROM ALL TOP AND BOTTOM PENETRATIONS THROUGHOUT TO ALLOW FOR INSPECTION
Gas Piping Inspection - Residential Failed 10/22/2020 10/22/2020 10/22/2020
Misc
Corrective Action Required
10/07/2020
-Secure gas flex line at fireplace
Gas Service Inspection - Residential Passed 10/22/2020 10/22/2020 10/22/2020
Misc
Resolved
10/22/2020
All Rough Inspection - Residential Not Ready 10/22/2020 10/22/2020 10/22/2020
Misc
Corrective Action Required
10/20/2020
-Ensure all top and bottom plate penetrations are fire blocked and sealed -10/22 SEVERAL TOP AND BOTTOM PLATE PENETRATIONS UNSEALED THROUGHOUT. NOT READY FEE ADDED, 4TH ALL ROUGH INSPECTION. PLEASE ENSURE CORRECTIONS DONE BEFORE RESCHEDULING INSPECTION HOUSE INSULATED WITHOUT APPROVAL - REMOVE INSULATION FROM ALL TOP AND BOTTOM PENETRATIONS THROUGHOUT TO ALLOW FOR INSPECTION
All Rough Inspection - Residential Passed 10/26/2020 10/26/2020 10/26/2020
Misc
Resolved
10/26/2020
Gas Piping Inspection - Residential Passed 10/27/2020 10/27/2020 10/27/2020
Misc
Resolved
10/27/2020
Sewer Service Inspection - R Passed 10/30/2020 (1:45) 10/30/2020 10/30/2020
Water Service Inspection - R Partial 11/2/2020 (8:00) 11/2/2020 11/02/2020
Misc
Corrective Action Required
11/02/2020
- INSPECTED PARTIAL ON COPPER FROM SITE OF FUTURE METER WELL LOCATION TO HOUSE ENTRANCE.
Water Service Inspection - R Passed 11/2/2020 (1:00) 11/2/2020 11/02/2020
Misc
Resolved
11/02/2020
Driveway Inspection Partial 11/13/2020 (P.M.) 11/13/2020 11/13/2020
Misc
Informational
11/13/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 11/20/2020 11/20/2020 11/20/2020
Misc
Informational
11/13/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 11/13/2020 (P.M.) 11/13/2020 11/23/2020
Sidewalk Inspection Partial 12/4/2020 (A.M.) 12/4/2020 12/04/2020
Misc
Informational
12/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 12/11/2020 12/11/2020 12/15/2020
Misc
Informational
12/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 1/5/2021 1/5/2021 01/05/2021
Misc
Corrective Action Required
01/05/2021
-Maintain erosion control on lot until sod is placed -Complete final grade and sod -address number color must contrast with background -splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -seal around all exterior light fixtures, seal along top of AC disconnect -non combustible attic access required at garage -repair drywall/backsplash tile at receptacle, master bath vanity -size attic access cover on 2nd floor to fit and seal properly -(2) bolts required at each post/beam connection at deck -Secure AC electrical whip within 12” of disconnect
Occupancy Inspection - Codes Residential Failed 1/13/2021 1/13/2021 01/13/2021
Misc
Corrective Action Required
01/05/2021
-Complete final grade and sod -splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -repair drywall/backsplash tile at receptacle, master bath vanity - 2017 NEC 314.21 Noncombustible surfaces that are broken or incomplete around boxes employing a flush-type cover or faceplate shall be repaired so there will be no gaps or open spaces greater than 3 mm (1/8 in.) at the edge of the box.
Occupancy Inspection - Codes Residential Failed 1/13/2021 01/13/2021
Misc
Corrective Action Required
01/13/2021
-Complete final grade and sod -splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -repair drywall/backsplash tile at receptacle, master bath vanity - 2017 NEC 314.21 Noncombustible surfaces that are broken or incomplete around boxes employing a flush-type cover or faceplate shall be repaired so there will be no gaps or open spaces greater than 3 mm (1/8 in.) at the edge of the box.
Occupancy Inspection - Codes Residential Temporary C of O 1/14/2021 1/14/2021 01/14/2021
Misc
Corrective Action Required
01/13/2021
-Complete final grade and sod -splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation OK FOR TCO - TCO EXPIRES 2/11/21
Plot Plan Inspection Passed 1/26/2021 1/26/2021 01/26/2021
Piers/Caissons Inspection - Residential Passed 01/26/2021
Occupancy Inspection - Codes Residential Full C of O 1/26/2021 1/26/2021 01/26/2021
Misc
Resolved
01/26/2021
Documents & Images
Date Uploaded File Type Document Name
06/03/2020 Application Form RT #23 - PERMIT APP
06/03/2020 LOT 23 FINAL
06/03/2020 RT #23 - Valentia - Mediterranean - Sheets- signed
06/03/2020 400311
06/03/2020 RT #23 - TRUSS LAYOUT
06/05/2020 Specifications APPROVED ROOF TRUSS PACKAGE
06/05/2020 Drawing APPROVED TRUSS LAYOUT
06/05/2020 Plans APPROVED HOUSE PLANS
06/05/2020 Plot Plan APPROVED PLOT PLAN
06/05/2020 Receipt Receipt for transaction:2020-002739
06/05/2020 Letter DS Building Permit
06/24/2020 Letter INSPECTION SUMMARY
07/02/2020 Letter Lot 23 Creekside at Raintree -Footing Inspection
07/02/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/12/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/20/2020 Letter INSPECTION SUMMARY
10/22/2020 Letter INSPECTION SUMMARY
10/22/2020 Letter INSPECTION SUMMARY
10/22/2020 Letter INSPECTION SUMMARY
10/23/2020 Receipt Receipt for transaction:2020-007146
10/26/2020 Letter INSPECTION SUMMARY
10/27/2020 Letter INSPECTION SUMMARY
10/30/2020 Letter INSPECTION SUMMARY
11/02/2020 Letter INSPECTION SUMMARY
11/02/2020 Letter INSPECTION SUMMARY
11/13/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/15/2020 Letter INSPECTION SUMMARY
01/05/2021 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
01/13/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter INSPECTION SUMMARY
01/14/2021 Letter Codes Temporary Certificate of Occupancy
01/26/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter INSPECTION SUMMARY
01/26/2021 Letter Field Certificate of Occupancy
01/26/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home