Permit Application Status

PRRES20200954


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200954
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO
04/15/2020
04/15/2020
10/15/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/17/2020 04/15/2020
Kim Brennan
Lot elevations
Corrective Action Required
04/15/2020

Existing and finish elevations at all property corners must be provided on the plot plan. Please show this information at the corner by the ADA ramp.
Planning Review (RES) Approved 04/17/2020 04/15/2020
Kim Brennan
Residential Plan Review Approved 04/17/2020 04/15/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,027.28 $1,027.28 Paid 04/15/2020
Right of Way Permit Fee $80.00 $80.00 Paid 04/15/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/15/2020
8331507-Sewer Connection Fee $390.00 $390.00 Paid 04/15/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 04/15/2020
Water Meter Fee $425.02 $425.02 Paid 04/15/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/28/2020 at 3:00 PM 04/30/2020
Misc
Informational
04/30/2020
3RD PARTY FOOTING BY DEREK PEREZ @ RES SIGNED & STAMPED BY BRADLEY HUXOL
Underslab Plumbing Inspection - Residential Failed 5/8/2020 5/8/2020 05/08/2020
Misc
Corrective Action Required
05/08/2020
INSPECTION NOT PERFORMED - POST ADDRESS - - BACKFILL AROUND FOUNDATION FOR ACCESS -
Underslab Plumbing Inspection - Residential Failed 5/14/2020 5/14/2020 05/13/2020
Misc
Corrective Action Required
05/08/2020
- INTERIOR DRAIN TILE BEING RUN DIAGONALLY NEEDS TO REACH OPPOSITE END OF FOUNDATION FOOTING -
Underslab Plumbing Inspection - Residential Passed 5/15/2020 5/15/2020 05/15/2020
Misc
Resolved
05/15/2020
Sewer Service Inspection - R Passed 6/15/2020 (1:00) 6/15/2020 06/15/2020
Water Service Inspection - R Passed 6/16/2020 (10:30) 6/16/2020 06/16/2020
Electrical Service Inspection Passed 7/20/2020 7/20/2020 07/20/2020
Gas Service Inspection - Residential Passed 7/20/2020 7/20/2020 07/20/2020
All Rough Inspection - Residential Failed 7/20/2020 7/20/2020 07/20/2020
Misc
Corrective Action Required
07/20/2020
- Protect and support pex at all showers/baths per manufacturer listing - Address broken stud at master bath vanity DWV - H2.5 strap missing 1st floor bed - EC#2 laundry, master bedroom per plans - Truss hangers per plans, hangers missing - Remove lid at back patio to allow inspections of truss hangers and straps - Truss bracing per plans - Nail all dbl truss together per plans - Fireblock vertical between framing and foundation wall every 10’ in basement per code - Fireblock above main service panel in basement between top plate and foundation wall - Protection plates at DWV clean outs and radon in basement bedroom #3 and bedroom #4 closets - Secure and protect gas line at basement fir down per code - Seal all penetrations and gaps in Fireblock between top plate and foundation wall in basement - Fire block at fir down and vertical to horizontal at fir down in basement - Secure pex per manufacturer listing at wet bar in basement
Gas Piping Inspection - Residential Failed 7/20/2020 7/20/2020 07/20/2020
Misc
Corrective Action Required
07/20/2020
- Secure and protect gas line at basement fur down per code
Gas Piping Inspection - Residential Passed 7/23/2020 7/23/2020 07/23/2020
Misc
Resolved
07/23/2020
All Rough Inspection - Residential Failed 7/23/2020 7/23/2020 07/23/2020
Misc
Corrective Action Required
07/23/2020
- Truss hangers per plans - TJC37 hanger missing in laundry
All Rough Inspection - Residential Passed 7/24/2020 7/24/2020 07/24/2020
Misc
Resolved
07/24/2020
Occupancy Inspection - Codes Residential Failed 9/23/2020 9/23/2020 09/23/2020
Misc
Corrective Action Required
09/23/2020
-Complete vanity light fixture hall bath, master bath, basement bath -Complete hood exhaust kitchen -GFCI protection required at dishwasher -Label dedicated outlet in garage and unfinished basement as not GFCI protected -High and low vents required for furnace/water heater combustion air -Egress ladder required at basement bedroom window -Cover panel required at electric main service panel with beaker locations marked -Complete light fixtures above basement stairs -Security screws at back door -Complete final grade and sod -Splash blocks at all downspout and sump,p pump discharge locations, minimum 36” distance from foundation -Final driveway and sidewalk inspections
Driveway Inspection Passed 8/5/2020 8/5/2020 09/23/2020
Misc
Informational
09/23/2020
On Wednesday,8-05-2020 I performed a driveway inspection that passed city standards
Sidewalk Inspection Passed 8/5/2020 8/5/2020 09/23/2020
Misc
Informational
09/23/2020
On Wednesday 8-05-2020 I performed a sidewalk inspection and it passed inspections.
Occupancy Inspection - Codes Residential Temporary C of O 10/1/2020 10/1/2020 10/01/2020
Misc
Corrective Action Required
09/23/2020
-Complete final grade and sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36” distance from foundation
Plot Plan Inspection Passed 10/14/2020
Occupancy Inspection - Codes Residential Failed 10/14/2020 10/14/2020 10/14/2020
Misc
Corrective Action Required
10/01/2020
- Remove sod cover from water meter lid
Occupancy Inspection - Codes Residential Full C of O 10/15/2020 10/15/2020 10/15/2020
Misc
Resolved
10/15/2020
Documents & Images
Date Uploaded File Type Document Name
04/15/2020 Letter Permit Application
04/15/2020 Plans Approved Drawings
04/15/2020 Letter Codes Residential Plan Review
04/15/2020 Plans Approved Truss Package
04/15/2020 Plans Approved Truss Layout
04/15/2020 Plot Plan Approved Plot Plan
04/15/2020 Receipt Receipt for transaction:2020-001555
04/15/2020 Letter DS Building Permit
04/30/2020 Letter Letter from Engineer
04/30/2020 Letter Letter from Engineer
04/30/2020 Letter INSPECTION SUMMARY
05/08/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/15/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/16/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter INSPECTION SUMMARY
07/23/2020 Letter INSPECTION SUMMARY
07/23/2020 Letter INSPECTION SUMMARY
07/24/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter INSPECTION SUMMARY
10/01/2020 Letter Codes Temporary Certificate of Occupancy
10/14/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/15/2020 Letter Field Certificate of Occupancy
10/15/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home