Permit Application Status

PRRES20200840


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200840
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED/UNFINISHED BASEMENT
04/01/2020
04/03/2020
10/27/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/03/2020 04/03/2020
Kim Brennan
Basement egress
Corrective Action Required
04/02/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
Planning Review (RES) Approved 04/06/2020 04/03/2020
Kim Brennan
Residential Plan Review Approved 04/06/2020 04/02/2020
Kim Brennan
Miscellaneous Correction
Corrective Action Required
04/02/2020

Please identify walk-out door on the drawings
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $959.04 $959.04 Paid 04/03/2020
Right of Way Permit Fee $80.00 $80.00 Paid 04/03/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/03/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 04/03/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 04/03/2020
Water Meter Fee $425.02 $425.02 Paid 04/03/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 4/29/2020 4/29/2020 04/29/2020
Misc
Corrective Action Required
04/29/2020
No address posted No approved plans on site No erosion control No engineered report for fill compaction at back of lot
Deck Final Inspection - Residential Passed 5/1/2020 05/01/2020
Misc
Informational
10/23/2020
Footing Inspection - Residential Passed 5/1/2020 5/1/2020 05/01/2020
Misc
Resolved
05/01/2020
No address posted No approved plans on site No erosion control No engineered report for fill compaction at back of lot
Underslab Plumbing Inspection - Residential Passed 5/20/2020 5/20/2020 at 7:18 AM 05/20/2020
Sewer Service Inspection - R Passed 6/23/2020 (11:15) 6/23/2020 06/23/2020
Water Service Inspection - R Passed 6/30/2020 (10:30) 6/30/2020 06/30/2020
Electrical Service Inspection Failed 7/22/2020 7/22/2020 07/22/2020
Misc
Corrective Action Required
07/22/2020
- COLOR CODE UFER GROUND
Gas Piping Inspection - Residential Failed 7/22/2020 7/22/2020 07/22/2020
Misc
Corrective Action Required
07/22/2020
- Secure gas flex line at fireplace
Gas Service Inspection - Residential Passed 7/22/2020 7/22/2020 07/22/2020
All Rough Inspection - Residential Failed 7/22/2020 7/22/2020 07/22/2020
Misc
Corrective Action Required
07/22/2020
- Maintain gravel filter on lot - Nail off PFH strap at garage - Tighten all anchor bolts in garage - Nut missing on anchor bolt in garage - Address electrical below flue clearance at fireplace, route and secure plastic conduit properly that wraps behind to front of flue - Secure gas flex line at fireplace - Seal all floor penetrations between 1st floor and basement - Strap top plate at DWV master bath - Protect and secure pex at showers and baths per manufacturer listing - Security blocking at front, back door, and basement door - Nail guard at DWV laundry - Fireblock deadspace bedroom#2 - EC#2 per plans - Nail dbl truss per plans - Anchor all beams to floor in basement - Fireblock vertical horizontal at basement fir down - Fireblock bores behind shower at vertical and horizontal in basement - Color code ufer ground - Hold down at NE side of dining windows per plans
All Rough Inspection - Residential Failed 7/27/2020 7/27/2020 07/27/2020
Misc
Corrective Action Required
07/22/2020
- Maintain gravel filter on lot - Seal all floor penetrations between 1st floor and basement - Security blocking at front, back door, and basement door -Seal Fireblock in deadspace bedroom#2 - EC#2 per plans and R602.10.7 - Fireblock vertical horizontal at basement fir down and all beam webs in finished -Seal gaps in horizontal and vertical fireblocking in fir out walls - tighten Hold down at NE side of dining windows per plans
All Rough Inspection - Residential Failed 7/29/2020 7/29/2020 07/29/2020
Misc
Corrective Action Required
07/27/2020
- Security blocking at basement sliding door
All Rough Inspection - Residential Passed 7/30/2020 7/30/2020 07/30/2020
Misc
Resolved
07/30/2020
Driveway Inspection Passed 8/19/2020 8/19/2020 08/19/2020
Misc
Informational
08/19/2020
On Wednesday, 8-19-2020. A field inspection for a driveway was conducted and driveway passes city spec’s.
Sidewalk Inspection Passed 8/19/2020 8/19/2020 08/19/2020
Misc
Informational
08/19/2020
On Wednesday,8-19-2020. A field inspection was conducted and sidewalk formsing and sub-base met standards to pour sidewalk. Inspection passes.
Electrical Service Inspection Passed 9/30/2020 9/30/2020 09/30/2020
Misc
Resolved
09/30/2020
Gas Piping Inspection - Residential Passed 09/30/2020
Misc
Resolved
09/30/2020
Occupancy Inspection - Codes Residential Failed 10/8/2020 10/8/2020 10/08/2020
Misc
Corrective Action Required
10/08/2020
-Complete final grade and sod -Place splash blocks at all downspout and sump pump discharge location, minimum 36” from foundation -Label all dedicated outlets in garage and unfinished basement as not GFCI protected -Combustion air vent(s) for furnace, hot water heater
Occupancy Inspection - Codes Residential Failed 10/14/2020 10/14/2020 10/14/2020
Misc
Corrective Action Required
10/08/2020
-Complete final grade and sod -Place splash blocks at all downspout and sump pump discharge location, minimum 36” from foundation
Occupancy Inspection - Codes Residential Temporary C of O 10/19/2020 10/19/2020 10/19/2020
Misc
Corrective Action Required
10/14/2020
-Complete final grade and sod -Place splash blocks at all downspout and sump pump discharge location, minimum 36” from foundation OK for TCO
Piers/Caissons Inspection - Residential Passed 5/1/2020 10/23/2020
Misc
Informational
10/23/2020
- POURED WITH FOOTING (1) 18x36 w/(4) # 4 VERT BARS -
Plot Plan Inspection Passed 10/23/2020 10/23/2020
Occupancy Inspection - Codes Residential Failed 10/23/2020 10/23/2020 10/23/2020
Misc
Corrective Action Required
10/19/2020
- sump pump discharge location, minimum 36” from foundation - - PROVIDE 6" WOOD SIDING TO SOD NORTH SIDE - - SUBMIT BACKFLOW CERTICATION LAWN IRRIGATION PERMIT PRRES20203261 - OK for TCO EXPIRES 11/02/2020
Occupancy Inspection - Codes Residential Full C of O 10/27/2020 10/27/2020 10/27/2020
Misc
Resolved
10/27/2020
Documents & Images
Date Uploaded File Type Document Name
04/01/2020 Letter Permit Application
04/02/2020 Letter Codes Residential Plan Review
04/02/2020 Plans Roof Truss Package
04/02/2020 Plans 3 HAWTHORNE RIDGE ROOF LAYOUT- signed
04/03/2020 Plans Approved Plans
04/03/2020 Plot Plan Approved Plot Plan
04/03/2020 Receipt Receipt for transaction:2020-001394
04/03/2020 Letter DS Building Permit
04/29/2020 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
05/01/2020 Letter INSPECTION SUMMARY
05/20/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
06/30/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/22/2020 Letter INSPECTION SUMMARY
07/27/2020 Letter INSPECTION SUMMARY
07/27/2020 Letter Codes Residential Plan Review
07/29/2020 Letter INSPECTION SUMMARY
07/30/2020 Letter INSPECTION SUMMARY
09/30/2020 Letter INSPECTION SUMMARY
09/30/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/19/2020 Letter Codes Temporary Certificate of Occupancy
10/23/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
10/23/2020 Letter INSPECTION SUMMARY
10/27/2020 Letter Field Certificate of Occupancy
10/27/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home