Permit Application Status

PRRES20200744


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200744
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - ENGINEERED FLOOR SYSTEM - COVERED PORCH
03/23/2020
04/09/2020
12/14/2020
Locations
Contacts
GALE HOMES II INC, Address:400 SW LONGVIEW BLVD STE 109  
MFAULKNER@GALECOMMUNITIES.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
MC ELECTRICAL SERVICES INC, Address:1502 N VANSANT RD, Phone:(816) 392-3970  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/25/2020 04/09/2020
Dylan Eppert
Basement egress
Corrective Action Required
04/07/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. MISSING EGRESS WELL AND LAG.
Residential Plan Review Approved 03/26/2020 04/08/2020
Dylan Eppert
07 Identify emergency escape openings from bedrooms
Corrective Action Required
03/24/2020

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
03/24/2020

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) NEED COMBO DETECTOR OUTSIDE OF BEDROOM #2
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,430.18 $1,430.18 Paid 04/09/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 04/09/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 04/09/2020
Water Meter Fee $425.02 $425.02 Paid 04/09/2020
Right of Way Permit Fee $80.00 $80.00 Paid 04/09/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/09/2020
Valuation Fee New Single Family $56.07 $56.07 Paid 08/27/2020
$1,486.25
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/21/2020 5/21/2020 05/21/2020
Sewer Service Inspection - R Passed 6/9/2020 (1:00) 6/9/2020 at 12:49 PM 06/09/2020
Water Service Inspection - R Partial 6/9/2020 (1:00) 6/9/2020 at 12:50 PM 06/09/2020
Water Service Inspection - R Passed 6/10/2020 (10:15) 6/10/2020 at 11:50 AM 06/10/2020
Underslab Plumbing Inspection - Residential Passed 6/11/2020 06/11/2020
All Rough Inspection - Residential Failed 8/31/2020 8/31/2020 08/31/2020
Misc
Corrective Action Required
08/31/2020
GENERAL- 1. Install outdoor fireplace 2. Install basement window PLUMBING- 1. Strap all 2” and smaller DWV piping at vertical mid-span 2. Proper nail plate protection and strap at over bored top plate penetration in upstairs laundry ELECTRICAL- 1. protect NM conductors minimum 6” aff at floor penetrations. 2. Identify black insulated GEC at both ends- At main & concrete encased electrode. FRAMING- 1. Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 12” oc nailing. 2. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge at exterior doors. 3. Double 2x12 floor joists with solid blocking under kitchen island per plan OK TO INSULATE
Electrical Service Inspection Passed 8/31/2020 8/31/2020 08/31/2020
Gas Piping Inspection - Residential Failed 8/31/2020 8/31/2020 08/31/2020
Misc
Corrective Action Required
08/31/2020
Secure gas piping at interior fireplace
Gas Service Inspection - Residential Passed 8/31/2020 8/31/2020 08/31/2020
All Rough Inspection - Residential Failed 9/2/2020 9/2/2020 09/02/2020
Misc
Corrective Action Required
08/31/2020
GENERAL- 1. Install outdoor fireplace 2. Install basement window OK TO INSULATE
Driveway Inspection Partial 9/23/2020 9/23/2020 09/23/2020
Misc
Informational
09/23/2020
Forms were placed and aggregate was present and compacted. RP 9-23-20
Driveway Inspection Passed 10/2/2020 10/2/2020 10/02/2020
Misc
Informational
09/23/2020
Forms were placed and aggregate was present and compacted. RP 9-23-20
Misc
Informational
10/02/2020
Finished driveway meets LS specs. RP 10-2-20
Occupancy Inspection - Codes Residential Failed 11/25/2020 11/25/2020 11/25/2020
Misc
Corrective Action Required
11/25/2020
-Provide engineer documentation regarding installation of retaining wall -Downspouts and sump piping to discharge minimum 36 inches from foundation -adjust grade or provide Guard rail at stairs to front stoop, grade from last riser (stoop) exceeds 30” within 36” horizontal from open side -seal top & sides of exterior lighting exposed to the elements -secondary locking device at sliding glass door -Locate and expose grounding electrode conductor connection to concrete encased electrode
Gas Piping Inspection - Residential Passed 11/25/2020
Misc
Resolved
11/25/2020
Secure gas piping at interior fireplace
All Rough Inspection - Residential Passed 11/25/2020
Misc
Resolved
11/25/2020
GENERAL- 1. Install outdoor fireplace 2. Install basement window OK TO INSULATE
Plot Plan Inspection Failed 11/25/2020
Misc
Corrective Action Required
11/25/2020
Final grade and sod per approved plot
Occupancy Inspection - Codes Residential Temporary C of O 11/30/2020 11/30/2020 11/30/2020
Misc
Corrective Action Required
11/25/2020
-Downspouts and sump piping to discharge minimum 36 inches from foundation -final grade and sod per approved plot TCO VALID THROUGH 12/30/2020
Plot Plan Inspection Passed 12/14/2020
Misc
Resolved
12/14/2020
Final grade and sod per approved plot
Erosion Control Inspection Residential Passed 12/14/2020
Occupancy Inspection - Codes Residential Full C of O 12/14/2020 12/14/2020 12/14/2020
Misc
Resolved
12/14/2020
-Downspouts and sump piping to discharge minimum 36 inches from foundation -final grade and sod per approved plot TCO VALID THROUGH 12/30/2020
Documents & Images
Date Uploaded File Type Document Name
03/23/2020 License_Tax_Application 2905 NW Audubon Lane
03/23/2020 Residental Permit Application 2905 NW Audubon Lane
04/06/2020 LOT 1447 FINAL
04/07/2020 Letter Codes Residential Plan Review
04/08/2020 Plans Approved Construction Plans
04/09/2020 Plot Plan Approved Plot Plan
04/09/2020 Receipt Receipt for transaction: 2020-001475
04/09/2020 Letter DS Building Permit
05/21/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
06/10/2020 Letter INSPECTION SUMMARY
06/11/2020 Letter INSPECTION SUMMARY
08/27/2020 2020_03_20_Lot 1447 Winterset_sealed
08/27/2020 Approved Plans Approved Basement Plan
08/27/2020 Receipt Receipt for transaction:2020-005756
08/31/2020 Letter INSPECTION SUMMARY
08/31/2020 Letter INSPECTION SUMMARY
08/31/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter INSPECTION SUMMARY
10/02/2020 Letter INSPECTION SUMMARY
11/24/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
11/25/2020 2905 NW Audubon Rock Wall Engineer Letter
11/30/2020 Letter Codes Temporary Certificate of Occupancy
12/14/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter INSPECTION SUMMARY
12/14/2020 Letter Codes Final Certificate of Occupancy
12/14/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home