Permit Application Status

PRRES20200102


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200102
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO
01/14/2020
01/29/2020
01/29/2021
Locations
Contacts
SPELLERBERG ENTERPRISES LLC, Address:613 NE VIEWPARK DR, Phone:(816) 550-5535  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
NEW HEIGHTS ELECTRIC LLC, Address:P O BOX 163, Phone:(816) 625-9504  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
SPELLERBERGENTERPRISES@GMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 01/16/2020 01/17/2020
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
01/14/2020

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304)
Plot Plan Review Approved 01/16/2020 01/17/2020
Kim Brennan
Right-of-way
Corrective Action Required
01/14/2020

The right-of-way with dimensions must be provided on the plot plan.
Basement opening elevations
Corrective Action Required
01/14/2020

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
As-graded plot plan
Corrective Action Required
01/14/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Lot elevations
Corrective Action Required
01/14/2020

Existing and finish elevations at all property corners must be provided on the plot plan. Elevations at property corners are off by several feet from the approved Master Drainage Plan. Please clarify.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,413.86 $1,413.86 Paid 01/29/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/29/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/29/2020
8331507-Sewer Connection Fee $630.00 $630.00 Paid 01/29/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 01/29/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 01/29/2020
9110078-Valuation Fee New Single Family $41.21 $41.21 Paid 11/06/2020
$1,455.07
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/5/2020 3/5/2020 03/05/2020
Erosion Control Inspection Residential Failed 3/31/2020 03/31/2020
Misc
Corrective Action Required
03/31/2020
- MAINTAIN SILT FENCE -
Underslab Plumbing Inspection - Residential Passed 3/31/2020 3/31/2020 03/31/2020
Sewer Service Inspection - R Passed 4/9/2020 4/9/2020 at 12:01 PM 04/09/2020
Water Service Inspection - R Passed 4/10/2020 4/10/2020 04/10/2020
Erosion Control Inspection Residential Failed 8/27/2020 8/27/2020 08/27/2020
Misc
Resolved
08/27/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/27/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Failed 8/27/2020 8/27/2020 08/27/2020
Misc
Resolved
09/02/2020
Electrical Service Inspection Failed 9/2/2020 9/2/2020 09/02/2020
Resolved
09/02/2020
Corrective Action Required
09/02/2020
- COLOR CODE/LABEL GROUNDING ELECTRODE CONDUCTOR
Gas Piping Inspection - Residential Failed 9/2/2020 9/2/2020 09/02/2020
Corrective Action Required
09/02/2020
- SECURE WARD FLEX AT FIREPLACE
Gas Service Inspection - Residential Passed 9/2/2020 9/2/2020 09/02/2020
All Rough Inspection - Residential Failed 9/2/2020 9/2/2020 09/02/2020
Misc
Corrective Action Required
08/27/2020
• Solid block above top plate between joists at garage furred down and kitchen •Fireblock top of HVAC chase in garage •Terminate NM (romex) at ceiling - kitchen, living room, breakfast, master bath, laundry, 2nd floor hallway •Terminate NM (romex) at wall in breakfast •Security blocking at front door, back door •Fireblock at top of chase in living room •Secure ward flex at fireplace •Seal top plate penetration - 2nd floor hallway •Protection plates at romex within 1 1/4” of end of framing member - 2nd floor bedroom •All exhaust fans should vent to exterior per plans •Structural straps required at all top plates bored 50% or more on interior bearing walls and exterior walls, see master bed/bath •Color code/label grounding electrode conductor •Terminate NM in basement W wall •Cleanout blocking main service panel in basement, move cleanout to grade •Anchor all steel columns to floor •Continue 3” nail pattern at header for garage portal •Pan off under cantilever in garage •LIB method strap in “X” or “V” pattern per plans
All Rough Inspection - Residential Failed 9/14/2020 9/14/2020 09/14/2020
Misc
Corrective Action Required
09/02/2020
•Protection plates at romex within 1 1/4” of end of framing member - 2nd floor bedroom OK to Insulate
Electrical Service Inspection Passed 9/14/2020 09/14/2020
Gas Piping Inspection - Residential Passed 9/14/2020 09/14/2020
All Rough Inspection - Residential Passed 9/15/2020 9/15/2020 09/15/2020
Misc
Resolved
09/15/2020
•Protection plates at romex within 1 1/4” of end of framing member - 2nd floor bedroom OK to Insulate
Misc
Informational
09/15/2020
Ok to rock
Piers/Caissons Inspection - Residential Passed 9/22/2020 (1:00) 9/22/2020 09/22/2020
Misc
Informational
09/22/2020
(2) piers 24” x 36”
Driveway Inspection Partial 9/29/2020 9/29/2020 09/29/2020
Misc
Informational
09/29/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Plot Plan Inspection Passed 10/27/2020 10/27/2020
Sidewalk Inspection Partial 11/3/2020 (A.M.) 11/3/2020 11/03/2020
Misc
Informational
11/03/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
All Rough Inspection - Residential Failed 11/9/2020 11/9/2020 11/09/2020
Misc
Corrective Action Required
11/09/2020
-Complete bath fan exhaust discharge line -Secure NM (romex) at office/storage rm ceiling -Fireblock deadspace at bathroom wall near shower
All Rough Inspection - Residential Passed 11/10/2020 11/10/2020 11/10/2020
Misc
Resolved
11/10/2020
Sidewalk Inspection Passed 11/10/2020 11/10/2020 11/11/2020
Misc
Informational
11/03/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 1/25/2021 01/25/2021
Misc
Corrective Action Required
09/14/2020
-E3902.16 AFCI protection - branch circuits that supply 120 volt, single phase, 15 and 20 volt amp outlets installed in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas and any similar areas. -AC COMPRESSOR CIRCUIT PROTECTION MIN 31.9 AMP, MAX OVERCURRENT 50 AMP -SECURE AC ELECTRICAL WHIP WITHIN 12” OF DISCONNECT -SEAL ALL PENETRATIONS IN SIDING, SEAL ALONG TOP OF METER CAN AND AC DISCONNECT
Occupancy Inspection - Codes Residential Full C of O 1/29/2021 1/29/2021 01/29/2021
Misc
Resolved
01/29/2021
Documents & Images
Date Uploaded File Type Document Name
01/14/2020 Letter Codes Residential Plan Review
01/29/2020 Receipt Receipt for transaction: 2020-000349
01/29/2020 Letter DS Building Permit
01/30/2020 Plot Plan DOC013020-01302020084000
03/05/2020 Letter INSPECTION SUMMARY
03/31/2020 Letter INSPECTION SUMMARY
03/31/2020 Letter INSPECTION SUMMARY
04/09/2020 Letter INSPECTION SUMMARY
04/10/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
08/27/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
09/02/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/15/2020 Letter INSPECTION SUMMARY
09/22/2020 Letter INSPECTION SUMMARY
09/29/2020 Letter INSPECTION SUMMARY
10/26/2020 Plot Plan As Graded Plot Plan
10/27/2020 Letter INSPECTION SUMMARY
11/03/2020 Letter INSPECTION SUMMARY
11/06/2020 Plans approved basement finish
11/06/2020 Receipt Receipt for transaction:2020-007446
11/09/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/11/2020 Letter INSPECTION SUMMARY
01/25/2021 Letter INSPECTION SUMMARY
01/29/2021 Letter Field Certificate of Occupancy
01/29/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home