Permit Application Status

PRRES20193631


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193631
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - SUSPENDED SLAB - UNFINISHED BASEMENT - ROOF TRUSS PACKAGE
12/17/2019
01/07/2020
07/20/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 12/20/2019 01/02/2020
Dylan Eppert
Miscellaneous Correction
Corrective Action Required
12/18/2019

CORRECT ADDRESS IS 3020 SW ARBORIDGE DR. NOT 3020 SE ARBORIDGE DR. PLEASE CORRECT.
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
12/18/2019

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) SQUARE FOOTAGE NOT PROVIDED FOR THE COVERED DECK ON CONSTRUCTION DRAWINGS.
Plot Plan Review Approved 12/20/2019 01/02/2020
Dylan Eppert
Lot elevations
Corrective Action Required
12/18/2019

Existing and finish elevations at all property corners must be provided on the plot plan. THE HIGH POINT ON THE SOUTH EAST SIDE APPEARS TO BE INCORRECT AS IT STATES 1080.50 PLEASE CLARIFY.
Planning Review (RES) Approved 12/20/2019 12/27/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,413.21 $1,413.21 Paid 01/07/2020
8331507-Sewer Connection Fee $630.00 $630.00 Paid 01/07/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 01/07/2020
Water Meter Fee $425.02 $425.02 Paid 01/07/2020
Right of Way Permit Fee $80.00 $80.00 Paid 01/07/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/07/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/31/2020 (11:30) 1/31/2020 01/31/2020
Foundation Inspection - Residential Passed 2/3/2020 2/3/2020 02/03/2020
Misc
Informational
02/03/2020
#4 12” OC horizontal & Vertical
Underslab Plumbing Inspection - Residential Passed 2/19/2020 2/19/2020 02/19/2020
Sewer Service Inspection - R Passed 2/25/2020 02/25/2020
Water Service Inspection - R Passed 2/28/2020 02/28/2020
Suspended Slab Inspection Passed 3/11/2020 3/11/2020 03/11/2020
Miscellaneous Correction
Informational
03/11/2020
Suspended garage slab #4 12 O.C.
Piers/Caissons Inspection - Residential Passed 4/13/2020 (1:15) 4/13/2020 04/13/2020
Misc
Informational
04/13/2020
(1) 24 x 36 (1) 24 x 40 covered deck piers
Erosion Control Inspection Residential Failed 5/7/2020 05/07/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/07/2020
- MAINTAIN SILT FENCE -
Electrical Service Inspection Passed 5/7/2020 5/7/2020 05/07/2020
Gas Piping Inspection - Residential Passed 5/7/2020 5/7/2020 05/07/2020
Gas Service Inspection - Residential Passed 5/7/2020 05/07/2020
All Rough Inspection - Residential Failed 5/7/2020 5/7/2020 05/07/2020
Misc
Corrective Action Required
05/07/2020
- PROVIDE 4 SOFFIT VENT COVERED DECK PER PLAN - - PROVIDE TRUSS HANGERS PER TRUSS LAYOUT, ABOVE STAIRWAY & MASTER - - SEAL UPWARD PENETRATIONS BEHIND OVEN - -PROVIDE 3 1.2 SCH 40 COLUMN GARAGE PER PLAN - - PROVIDE (2) STHD14R AT STAIRWAY PER PLAN - - BEND TABS ON SCH 40 COLUMNS BASEMENT - -PROVIDE ANCHOR BOLTS SCH 40 COLUMNS SUSPENDED GARAGE - - PROVIDE MIN 7' CONCRETE HEADER CLEARANCE @ SUSPENDED OPENING PER PLAN - - BASEMENT TIGHTEN ALL ANCHOR BOLTS THAT SHALL BE IN MIDDLE 1/3 OF WIDTH OF PLATE - - PROVIDE 800 LB HOLDOWN EC#2 BEHIND BASEMENT DOOR PER PLAN - - COMPLETE FIREPLACE VENT - -PROVIDE FLASHING ABOVE HORIZONTAL TRIM GARAGE DOORS -
All Rough Inspection - Residential Failed 5/13/2020 5/13/2020 05/13/2020
Misc
Corrective Action Required
05/07/2020
-PROVIDE EFFECTIVE EROSION CONTROL BEFORE ANY FURTHER INSPECTIONS - PROVIDE TRUSS HANGERS PER TRUSS LAYOUT, ABOVE STAIRWAY & MASTER - -PROVIDE 3 1.2 SCH 40 COLUMN GARAGE PER PLAN - - PROVIDE (2) STHD14R AT STAIRWAY PER PLAN - - BASEMENT TIGHTEN ALL ANCHOR BOLTS THAT SHALL BE IN MIDDLE 1/3 OF WIDTH OF PLATE - - COMPLETE FIREPLACE VENT - -PROVIDE FLASHING ABOVE HORIZONTAL TRIM GARAGE DOORS - ADDRESS HEADERS ABOVE BASEMENT WINDOWS -
All Rough Inspection - Residential Passed 5/13/2020 05/13/2020
Misc
Resolved
05/13/2020
Sidewalk Inspection Passed 6/3/2020 6/3/2020 06/03/2020
Misc
Informational
06/03/2020
On Wednesday 6-03-2020 I preformed a sidewalk inspection. Sub grade and forming passed for installation.
Driveway Inspection Passed 6/3/2020 6/3/2020 06/03/2020
Misc
Informational
06/03/2020
On Wednesday, 6-03-2020. I performed a drive approach inspection. Sub grade and forming passed for drive installation.
Occupancy Inspection - Codes Residential Failed 7/14/2020 7/14/2020 07/14/2020
Misc
Corrective Action Required
07/14/2020
- Terminate and complete exterior lighting at garage - Hood required at cooktop in kitchen - Fire/Co detector(s) required outside 1st floor bedroom vicinity - Garage door must be self closing - Cover plates at all receptacles - No access to jacuzzi tub motor, access panel in water closet is on opposite end of tub with motor - Dishwasher GFCI protection - Terminate or removed bundled Romex hanging in E corner of basement - Seal all penetrations in siding - No current at GFCI receptacle at front porch to test
Occupancy Inspection - Codes Residential Full C of O 7/20/2020 7/20/2020 07/20/2020
Misc
Resolved
07/20/2020
Plot Plan Inspection Passed 07/20/2020
Documents & Images
Date Uploaded File Type Document Name
12/27/2019 Letter Codes Residential Plan Review
01/07/2020 Receipt Receipt for transaction: 2020-000069
01/07/2020 Receipt Receipt for transaction: 2020-000069
01/07/2020 Receipt Receipt for transaction: 2020-000069
01/07/2020 Receipt Receipt for transaction: 2020-000069
01/07/2020 Receipt Receipt for transaction: 2020-000069
01/07/2020 Letter DS Building Permit
01/08/2020 Plot Plan DOC010820-010
01/21/2020 scan_98498_2020-01-21-10-19-07
01/31/2020 Letter INSPECTION SUMMARY
02/03/2020 Letter INSPECTION SUMMARY
02/19/2020 Letter INSPECTION SUMMARY
02/25/2020 Letter INSPECTION SUMMARY
02/28/2020 Letter INSPECTION SUMMARY
03/11/2020 Letter INSPECTION SUMMARY
04/13/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter 20 Hawthorne Ridge Garage Beam Letter - Signed
05/13/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
07/14/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter Field Certificate of Occupancy
07/20/2020 Letter Codes Final Certificate of Occupancy
07/20/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home