Permit Application Status

PRRES20193630


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193630
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 02/12/2020 12:00 AM by username 'Michael Harkins'. STOP WORK ORDER removed on 03/23/2020 12:00 AM by username 'Michael Harkins'.
12/17/2019
12/30/2019
09/18/2021
Locations
Contacts
ROBERT A WASHAM CONSTRUCTION INC, Address:2058 NW SOUTH OUTER RD, Phone:(816) 224-5583  
MARKV@ROBWASHAMHOMES.COM  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
MARKV@ROBWASHAMHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 12/19/2019 12/30/2019
Development Center
07 Identify emergency escape openings from bedrooms
Corrective Action Required
12/17/2019

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) MISSING FOR MASTER BEDROOM AND BASEMENT.
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
12/17/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) MISSING IN ALL ROOMS AND THE BASEMENT
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
12/17/2019

Identify roof covering material (IRC Section R905) COULD NOT LOCATED ON PLANS
Miscellaneous Correction
Corrective Action Required
12/17/2019

WHICH MASTER BATHROOM LAYOUT WILL THE BUILDER BE USING?
Plot Plan Review Approved 12/19/2019 12/18/2019
Dylan Eppert
As-graded plot plan
Corrective Action Required
12/17/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
City infrustructure
Corrective Action Required
12/17/2019

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. PLEASE PROVIDE ELEVATIONS FOR FIELD INLET
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,389.95 $1,389.95 Paid 12/30/2019
8331507-Sewer Connection Fee $540.00 $540.00 Paid 12/30/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 12/30/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 12/30/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/30/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/30/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 09/11/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 1/31/2020 01/31/2020
Misc
Corrective Action Required
01/31/2020
Provide address - Provide erosion control & gravel filter - Provide 3rd party inspection within 48 hours of inspection - Provide engineers report for compaction - Letter needs to address frost footing at walkout -
Footing Inspection - Residential Failed - Stop Work 2/11/2020 02/12/2020
Misc
Corrective Action Required
01/31/2020
Provide address - Provide erosion control & gravel filter - Provide 3rd party inspection within 48 hours of inspection - Provide engineers report for compaction - Letter needs to address frost footing at walkout - 2/11/20 EMAIL & CALL BUILDER NO CONTACT FOOTING & FOUNDATION POURED WITHOUT APPROVAL NO ENGINEER REPORT STOP WORK ORDER ISSUED
Footing Inspection - Residential Failed 3/3/2020 3/3/2020 03/03/2020
Misc
Corrective Action Required
02/12/2020
Provide address - Provide erosion control & gravel filter - Provide 3rd party inspection within 48 hours of inspection - Provide engineers report for compaction - Letter needs to address frost footing at walkout - 2/11/20 EMAIL & CALL BUILDER NO CONTACT FOOTING & FOUNDATION POURED WITHOUT APPROVAL NO ENGINEER REPORT STOP WORK ORDER ISSUED
Misc
Corrective Action Required
03/03/2020
Insulation is not installed per code. contact Mark Harding, see email to RES. do not cover.
Underslab Plumbing Inspection - Residential Passed 3/23/2020 03/23/2020
Sewer Service Inspection - R Passed 4/1/2020 4/1/2020 04/01/2020
Water Service Inspection - R Partial 5/9/2020 (11:00) 4/2/2020 04/02/2020
Water Service Inspection - R Passed 4/2/2020 4/2/2020 at 1:42 PM 04/02/2020
All Rough Inspection - Residential Partial 5/7/2020 5/7/2020 05/07/2020
Misc
Informational
05/07/2020
- GARAGE PORTAL FRAME STHD 14 NAILED, NAILING PATTERN COMPLETE, WINDOW WRAP INSTALLED WINDOWS ABOVE & BELOW DEK, OK TO COVER -
Footing Inspection - Residential Passed 3/5/2020 5/13/2020 05/13/2020
Misc
Resolved
05/12/2020
Provide address - Provide erosion control & gravel filter - Provide 3rd party inspection within 48 hours of inspection - Provide engineers report for compaction - Letter needs to address frost footing at walkout - 2/11/20 EMAIL & CALL BUILDER NO CONTACT FOOTING & FOUNDATION POURED WITHOUT APPROVAL NO ENGINEER REPORT STOP WORK ORDER ISSUED
Misc
Resolved
05/12/2020
Insulation is not installed per code. contact Mark Harding, see email to RES. do not cover.
Misc
Resolved
05/13/2020
check repair of insulation at rear frost footing.
Misc
Informational
05/13/2020
- Foam insulation along footing inspected -
Erosion Control Inspection Residential Failed 06/04/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/04/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 6/10/2020 6/10/2020 06/10/2020
Misc
Informational
05/07/2020
- GARAGE PORTAL FRAME STHD 14 NAILED, NAILING PATTERN COMPLETE, WINDOW WRAP INSTALLED WINDOWS ABOVE & BELOW DEK, OK TO COVER -
Miscellaneous Correction
Corrective Action Required
06/10/2020
—NO PLANS ON SITE— -PROVIDE APPROVED PLANS AND RESCHEDULE -SCHEDULE GAS AND ELECTRIC SERVICE INSPECTIONS FOR SAME TIME
Miscellaneous Correction
Corrective Action Required
06/10/2020
—NO PLANS ON SITE— -PROVIDE APPROVED PLANS AND RESCHEDULE -SCHEDULE GAS AND ELECTRIC SERVICE INSPECTIONS FOR SAME TIME
Electrical Service Inspection Passed 06/11/2020
Gas Piping Inspection - Residential Passed 06/11/2020
All Rough Inspection - Residential Failed 6/11/2020 6/11/2020 06/11/2020
Misc
Informational
06/10/2020
- GARAGE PORTAL FRAME STHD 14 NAILED, NAILING PATTERN COMPLETE, WINDOW WRAP INSTALLED WINDOWS ABOVE & BELOW DEK, OK TO COVER -
Miscellaneous Correction
Resolved
06/11/2020
—NO PLANS ON SITE— -PROVIDE APPROVED PLANS AND RESCHEDULE -SCHEDULE GAS AND ELECTRIC SERVICE INSPECTIONS FOR SAME TIME
Miscellaneous Correction
Resolved
06/11/2020
—NO PLANS ON SITE— -PROVIDE APPROVED PLANS AND RESCHEDULE -SCHEDULE GAS AND ELECTRIC SERVICE INSPECTIONS FOR SAME TIME
Miscellaneous Correction
Corrective Action Required
06/11/2020
-TIGHTEN ALL ANCHOR BOLTS IN GARAGE -PROTECT PEX IN CHASE FROM B VENT -INSULATE AND SEAL CANTILEVER IN GARAGE -
Miscellaneous Correction
Corrective Action Required
06/11/2020
-TIGHTEN ALL ANCHOR BOLTS IN GARAGE -PROTECT PEX IN CHASE FROM B VENT -INSULATE AND SEAL CANTILEVER IN GARAGE -FIREBLOCK ALL CHASES OR DEAD SPACES -ELECTRICAL PROTECTION PLATES IN PANTRY, BEDROOM 2 EAST WALL, -NAIL 2X6 CONNECTED TO HEADER OVER BATHROOMS -BOCCA PLATES AT MASTER BATH TOILET ROOM -ADDRESS MISSING DOUBLE 2X12 IN BEDROOM 2 -VENT ALL BATH EXHAUST FANS TO EXTERIOR -FIRE STOP AT TUB TRAPS -FIRE STOP DUCT CHASE AT GARAGE FLOOR/ STAIRWELL WALL -TIGHTEN ALL ANCHOR BOLTS IN BASEMENT -PROVIDE BLOCKING ON TOP OF WALLS AT CANTILEVERS -FIRE STOP BEAM WEBS IN WALLS
All Rough Inspection - Residential Failed 6/19/2020 6/19/2020 06/19/2020
Misc
Informational
06/11/2020
- GARAGE PORTAL FRAME STHD 14 NAILED, NAILING PATTERN COMPLETE, WINDOW WRAP INSTALLED WINDOWS ABOVE & BELOW DEK, OK TO COVER -
Miscellaneous Correction
Resolved
06/18/2020
-TIGHTEN ALL ANCHOR BOLTS IN GARAGE -PROTECT PEX IN CHASE FROM B VENT -INSULATE AND SEAL CANTILEVER IN GARAGE -
Miscellaneous Correction
Corrective Action Required
06/11/2020
-VERTICAL FIRE STOP END OF STAIRWELL WALL -TIGHTEN ALL ANCHOR BOLTS IN BASEMENT -PROVIDE BLOCKING ON TOP OF WALLS AT CANTILEVERS- GARAGE
All Rough Inspection - Residential Not Ready 6/22/2020 6/22/2020 06/22/2020
Misc
Informational
06/19/2020
- GARAGE PORTAL FRAME STHD 14 NAILED, NAILING PATTERN COMPLETE, WINDOW WRAP INSTALLED WINDOWS ABOVE & BELOW DEK, OK TO COVER -
Miscellaneous Correction
Corrective Action Required
06/19/2020
***EXPOSE BASEMENT WALLS FOR INSPECTION**** —DO NOT SHEETROCK— -TIGHTEN ALL ANCHOR BOLTS IN BASEMENT -PROVIDE BLOCKING ON TOP OF WALLS AT CANTILEVERS- GARAGE
All Rough Inspection - Residential Passed 6/23/2020 6/23/2020 06/23/2020
Misc
Informational
06/22/2020
- GARAGE PORTAL FRAME STHD 14 NAILED, NAILING PATTERN COMPLETE, WINDOW WRAP INSTALLED WINDOWS ABOVE & BELOW DEK, OK TO COVER -
Miscellaneous Correction
Resolved
06/23/2020
***EXPOSE BASEMENT WALLS FOR INSPECTION**** —DO NOT SHEETROCK— -TIGHTEN ALL ANCHOR BOLTS IN BASEMENT -PROVIDE BLOCKING ON TOP OF WALLS AT CANTILEVERS- GARAGE
Gas Service Inspection - Residential Passed 7/17/2020 7/17/2020 07/16/2020
Driveway Inspection Passed 8/5/2020 (P.M.) 8/5/2020 08/06/2020
Misc
Informational
08/06/2020
On Wednesday, 8-05-2020. I performed a driveway inspection that meets city spec’s and it passes inspection to place concrete.
Plot Plan Inspection Passed 8/25/2020 08/25/2020
Occupancy Inspection - Codes Residential Failed 9/8/2020 9/8/2020 09/08/2020
Misc
Corrective Action Required
09/08/2020
-PROVIDE SOD -PROVIDE SPLASH BLOCKS/ DRAINAGE 36” AWAY FROM FOUNDATION MINIMUM -PAY ALL FEES BEFORE FINAL OCCUPANCY -SEAL WALL AT RECEPTACLE IN DOWNSTAIRS BATH -PROVIDE STAIRS IN GARAGE -PROVIDE SECONDARY SECURITY BOLT AT SLIDER -OVERFLOW DISCHARGE TO BE MAX 6” FORM FLOOR AT HOT WATER HEATER -ALL EXTERIOR LIGHT FIXTURES BELOW 7’ TO BE SEALED ON THE BOTTOM FOR SECURITY -BOLT RIM JOISTS TO POSTS -PROVIDE CLIP AT POST/ RIM ON CORNER AT STAIRS -ADD JOIST AND BOLTS AT STAIRS TO SUPPORT STRINGERS
Misc
Corrective Action Required
09/08/2020
-PROVIDE SOD -PROVIDE SPLASH BLOCKS/ DRAINAGE 36” AWAY FROM FOUNDATION MINIMUM -PAY ALL FEES BEFORE FINAL OCCUPANCY -SEAL WALL AT RECEPTACLE IN DOWNSTAIRS BATH -PROVIDE STAIRS IN GARAGE -PROVIDE SECONDARY SECURITY BOLT AT SLIDER -OVERFLOW DISCHARGE TO BE MAX 6” FORM FLOOR AT HOT WATER HEATER -ALL EXTERIOR LIGHT FIXTURES BELOW 7’ TO BE SEALED ON THE BOTTOM FOR SECURITY -BOLT RIM JOISTS TO POSTS -PROVIDE CLIP AT POST/ RIM ON CORNER AT STAIRS -ADD JOIST AND BOLTS AT STAIRS TO SUPPORT STRINGERS -OBTAIN LAWN IRRIGATION PERMIT AND BACKFLOW CERTIFICATION
Occupancy Inspection - Codes Residential Temporary C of O 9/11/2020 9/11/2020 09/11/2020
Misc
Resolved
09/11/2020
-PROVIDE SOD -PROVIDE SPLASH BLOCKS/ DRAINAGE 36” AWAY FROM FOUNDATION MINIMUM -PAY ALL FEES BEFORE FINAL C.O.
Misc
Corrective Action Required
09/11/2020
-PROVIDE SOD -PROVIDE SPLASH BLOCKS/ DRAINAGE 36” AWAY FROM FOUNDATION -OBTAIN LAWN IRRIGATION PERMIT AND BACKFLOW CERTIFICATION -PAY ALL FEES BEFORE FINAL C.O.
Erosion Control Inspection Residential Failed 09/16/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/04/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/16/2020
-EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -CLEAN STREETS
Erosion Control Inspection Residential Failed 09/16/2020
Misc
Corrective Action Required
09/16/2020
-deficient erosion control installation, shall be in compliance within two days. No further inspections until complete
Deck Final Inspection - Residential Passed 09/17/2020
Piers/Caissons Inspection - Residential Passed 09/17/2020
Miscellaneous Correction
Informational
09/17/2020
3RD PARTY INSPECTION LETTER ON FILE
Occupancy Inspection - Codes Residential Failed 9/17/2020 9/17/2020 09/17/2020
Misc
Corrective Action Required
09/11/2020
-PROVIDE SOD -PROVIDE SPLASH BLOCKS/ DRAINAGE 36” AWAY FROM FOUNDATION -OBTAIN LAWN IRRIGATION PERMIT AND BACKFLOW CERTIFICATION -PAY ALL FEES BEFORE FINAL C.O.
Occupancy Inspection - Codes Residential Full C of O 9/18/2020 9/18/2020 09/18/2020
Misc
Resolved
09/18/2020
-PROVIDE SOD -PROVIDE SPLASH BLOCKS/ DRAINAGE 36” AWAY FROM FOUNDATION -OBTAIN LAWN IRRIGATION PERMIT AND BACKFLOW CERTIFICATION -PAY ALL FEES BEFORE FINAL C.O.
Erosion Control Inspection Residential Passed 09/18/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
09/16/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/16/2020
-EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -CLEAN STREETS
Documents & Images
Date Uploaded File Type Document Name
12/17/2019 Letter Codes Residential Plan Review
12/30/2019 Receipt Receipt for transaction: 2019-007866
12/30/2019 Letter DS Building Permit
12/30/2019 Plot Plan DOC123019-001
01/31/2020 Letter INSPECTION SUMMARY
02/12/2020 Letter Stop Work Order
02/13/2020 Letter INSPECTION SUMMARY
02/13/2020 Letter WW014 - PERMIT APPLICATION
03/03/2020 Letter INSPECTION SUMMARY
03/23/2020 Letter INSPECTION SUMMARY
03/23/2020 Engineer Report/Study 19-1168-dr-1 (Whispering Woods)
03/23/2020 Engineer Report/Study 19-1168-dr-1B (Whispering Woods)
04/01/2020 Letter INSPECTION SUMMARY
04/02/2020 Letter INSPECTION SUMMARY
04/02/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
06/04/2020 Letter INSPECTION SUMMARY
06/04/2020 Letter INSPECTION SUMMARY
06/04/2020 Letter Stop Work Order
06/10/2020 Letter INSPECTION SUMMARY
06/11/2020 Letter INSPECTION SUMMARY
06/11/2020 Letter INSPECTION SUMMARY
06/11/2020 Letter INSPECTION SUMMARY
06/19/2020 Letter INSPECTION SUMMARY
06/22/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
08/07/2020 Engineer Report/Study Deck Pier Inspection - 1812 SW River Run Drive - Lot 14 Whispering Woods
08/24/2020 Plot Plan APPROVED AS-BUILT
08/25/2020 Letter INSPECTION SUMMARY
08/25/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/11/2020 Receipt Receipt for transaction:2020-006179
09/11/2020 Letter Codes Temporary Certificate of Occupancy
09/16/2020 Letter INSPECTION SUMMARY
09/16/2020 Letter INSPECTION SUMMARY
09/17/2020 Letter INSPECTION SUMMARY
09/17/2020 Letter INSPECTION SUMMARY
09/17/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter Codes Final Certificate of Occupancy
09/18/2020 Letter Field Certificate of Occupancy
09/18/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home