Summary
PRRES20193519
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PORCH - ROOF TRUSS PACKAGE
12/03/2019
12/20/2019
12/11/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/05/2019 12/13/2019
Dylan Eppert
Property boundary
Corrective Action Required
12/04/2019

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. ON NORTH SIDE BEARING ISN'T CORRECT ON EAST SIDE DISTANCE ISN'T CORRECT ON SOUTH SIDE BEARING DOESN'T APPEAR CORRECT
Residential Plan Review Approved 12/05/2019 12/04/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,291.58 $1,291.58 Paid 12/20/2019
8331504-EFHB Middle Big Creek, Full $703.08 $703.08 Paid 12/20/2019
8331507-Sewer Connection Fee $630.00 $630.00 Paid 12/20/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 12/20/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 12/20/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/20/2019
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/20/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/6/2020 (1:00) 2/6/2020 02/06/2020
Underslab Plumbing Inspection - Residential Passed 3/6/2020 03/06/2020
Sewer Service Inspection - R Passed 3/26/2020 3/26/2020 at 12:50 PM 03/26/2020
Sidewalk Inspection Failed 3/26/2020 03/26/2020
Misc
Corrective Action Required
03/26/2020
It appears that the curb was broken by the contractor that install the water line going to the house. Do not pass the sidewalk or driveway until the curb has been fixed.
Water Service Inspection - R Passed 3/27/2020 3/27/2020 03/27/2020
Erosion Control Inspection Residential Failed 4/17/2020 04/17/2020
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
04/17/2020
STREET CLEAN UP REQUIRED AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - - MAINTAIN SILT FENCE -
Piers/Caissons Inspection - Residential Passed 5/20/2020 (1:15) 5/20/2020 05/20/2020
Misc
Informational
05/20/2020
(2) 24 x 36 (1) 24 x 40 w/ 4 # 4 vert bars per plan
Electrical Service Inspection Passed 6/29/2020 6/29/2020 06/29/2020
Gas Piping Inspection - Residential Passed 6/29/2020 6/29/2020 06/29/2020
Gas Service Inspection - Residential Passed 6/29/2020 6/29/2020 06/29/2020
All Rough Inspection - Residential Failed 6/29/2020 6/29/2020 06/29/2020
Misc
Corrective Action Required
06/29/2020
- Garage PFH straps per plan - H2.5 straps missing garage, 1st floor bed, back deck - Nail off all H2.5 straps - Fireblock at top of HVAC, DWV, radon fir out in garage - Fireblock st top of HVAC pex chase living room - Protect and support pex at showers - Seal all top and bottom plate penetrations - Seal penetrations at 1st/2nd floor stairs - Solid Fireblock at landing between 1st and 2nd floor - Truss bracing per plans 2nd floor - Truss hangers per plan - EC#2 800 lb hold downs per plans - (2) 2x10 header at egress window per plans basement - Flashing at garage trim, 2nd floor back window - (3) deck piers per plans - Ledger locks at deck install per manufacturer listing
All Rough Inspection - Residential Failed 7/8/2020 7/8/2020 07/08/2020
Misc
Corrective Action Required
06/29/2020
- Fireblock at top of HVAC, DWV, radon fir out in garage - Fireblock the vertical to horizontal - Fireblock at top of HVAC pex chase living room - seal and fill all gaps in Fireblock, fireblock horizontal at top of both chases in living room - Protect and support pex at showers per manufacturer listing - Seal all bottom plate penetrations - 1st floor bed - Seal penetrations at 1st/2nd floor stairs - Truss bracing per plans 2nd floor - Truss hangers per plan - Flashing at garage trim, 2nd floor back window
All Rough Inspection - Residential Failed 7/10/2020 7/10/2020 07/10/2020
Misc
Corrective Action Required
07/08/2020
- Protect and support pex at showers per manufacturer listing - Seal all bottom plate penetrations - 1st floor bed - Seal penetrations at 1st/2nd floor stairs - Truss bracing per plans 2nd floor - Truss hangers per plan - Flashing at garage trim, 2nd floor back window
All Rough Inspection - Residential Failed 7/13/2020 7/13/2020 07/13/2020
Misc
Corrective Action Required
07/10/2020
- Protect and support pex at showers per manufacturer listing
All Rough Inspection - Residential Passed 7/14/2020 7/14/2020 07/14/2020
Misc
Resolved
07/14/2020
Driveway Inspection Partial 8/4/2020 8/4/2020 08/04/2020
Misc
Informational
08/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 8/4/2020 8/4/2020 08/04/2020
Misc
Corrective Action Required
03/26/2020
It appears that the curb was broken by the contractor that install the water line going to the house. Do not pass the sidewalk or driveway until the curb has been fixed.
Misc
Informational
08/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
08/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 8/11/2020 8/11/2020 08/12/2020
Misc
Informational
08/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 8/11/2020 8/11/2020 08/12/2020
Misc
Corrective Action Required
08/04/2020
It appears that the curb was broken by the contractor that install the water line going to the house. Do not pass the sidewalk or driveway until the curb has been fixed.
Misc
Informational
08/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
08/04/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 11/25/2020 11/25/2020 11/25/2020
Misc
Corrective Action Required
11/25/2020
- INSTALL HOOD AND RANGE, HOOD HAD OPEN WIRING AT WALL. -INSPECT ALL EXTERIOR ITEMS A RE-INSPECTION.
Plot Plan Inspection Passed 12/11/2020
Occupancy Inspection - Codes Residential Full C of O 12/11/2020 12/11/2020 12/11/2020
Misc
Resolved
12/11/2020
Documents & Images
Date Uploaded File Type Document Name
12/04/2019 Letter Codes Residential Plan Review
12/20/2019 Receipt Receipt for transaction: 2019-007787
12/20/2019 Letter DS Building Permit
12/20/2019 Plot Plan DOC122019-12202019132118
02/06/2020 Letter INSPECTION SUMMARY
03/06/2020 Letter INSPECTION SUMMARY
03/26/2020 Letter INSPECTION SUMMARY
03/26/2020 Letter DE-Daily Inspection Summary
03/27/2020 Letter INSPECTION SUMMARY
04/17/2020 Letter INSPECTION SUMMARY
05/20/2020 Letter INSPECTION SUMMARY
05/20/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
07/10/2020 Letter INSPECTION SUMMARY
07/13/2020 Letter INSPECTION SUMMARY
07/14/2020 Letter INSPECTION SUMMARY
08/04/2020 Letter INSPECTION SUMMARY
08/04/2020 Letter INSPECTION SUMMARY
08/04/2020 Letter INSPECTION SUMMARY
08/12/2020 Letter INSPECTION SUMMARY
08/12/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter INSPECTION SUMMARY
12/11/2020 Letter Field Certificate of Occupancy
12/11/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home