Permit Application Status

PRRES20193426


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193426
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY PARTIALLY FINISHED BASEMENT COVERED DECK
11/20/2019
11/25/2019
10/07/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
PERMITTING@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 11/22/2019 11/22/2019
Steve Conrick
Plot Plan Review Approved 11/22/2019 11/22/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,306.41 $1,306.41 Paid 11/25/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/25/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/25/2019
8331507-Sewer Connection Fee $540.00 $540.00 Paid 11/25/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 11/25/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 11/25/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/31/2019 12/31/2019 12/31/2019
Underslab Plumbing Inspection - Residential Passed 2/10/2020 2/10/2020 02/10/2020
Water Service Inspection - R Passed 4/8/2020 (10:45) 4/8/2020 04/08/2020
Sewer Service Inspection - R Passed 4/9/2020 4/9/2020 at 1:10 PM 04/09/2020
Erosion Control Inspection Residential Failed 5/12/2020 05/12/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/12/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Electrical Service Inspection Passed 5/12/2020 5/12/2020 05/12/2020
Gas Piping Inspection - Residential Passed 5/12/2020 5/12/2020 05/12/2020
Gas Service Inspection - Residential Passed 5/12/2020 05/12/2020
All Rough Inspection - Residential Failed 5/12/2020 5/12/2020 05/12/2020
Misc
Corrective Action Required
05/12/2020
- ADDRESS BROKEN TRUSS MASTER BED - - ADDRESS BORING & NOTCHING JOIST BED 3 - - PROVIDE PFH PORTAL FRAMING PER PLAN GARAGE - - PROVIDE ANCHOR BOLTS PLATE BREAKS GARAGE - - PROVIDE ANCHOR BOLTS BOTTOM PLATE BASEMENT - - PROVIDE HANGERS PER TRUSS SCHEDULE - - PROVIDE JOIST HANGER ABOVE RADON LINES BASEMENT - - PROVIDE 4 SOFFIT VENTS 1 ROOF VENT COVERED PATIO PER PLAN - - SEAL ALL LOW VOLT PENETRATIONS TOP & BOTTOM PLATE - - FIRE BLOCK DEAD SPACE PANTRY/MUD ROOM - -PROVIDE SOLID SECURITY BLOCKING DECK DOOR - - PROVIDE BLOCKING SHEATHING BREAKS - - PROVIDE SCH 40 COLUMNS BED # 3 PER PLANS - - KTICHEN WALL AT RANGE SHALL BE 2 X 6 FULL HEIGHT CONTINUOUS PER PLAN -
Erosion Control Inspection Residential Failed 5/13/2020 05/13/2020
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/13/2020
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/13/2020
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. CLEAN MUD AND GRAVEL IN STREET
All Rough Inspection - Residential Passed 5/19/2020 5/19/2020 05/19/2020
Misc
Corrective Action Required
05/12/2020
Sidewalk Inspection Partial 6/5/2020 6/5/2020 06/05/2020
Misc
Informational
06/05/2020
Forms were placed and aggregate was present and compacted. They will be using KCMMB mix and white cure. RP 6-5-20
Driveway Inspection Partial 6/5/2020 6/5/2020 06/05/2020
Misc
Informational
06/05/2020
Forms were placed and aggregate was present and compacted. RP 6-5-20
Sidewalk Inspection Passed 6/12/2020 6/12/2020 06/17/2020
Misc
Informational
06/05/2020
Forms were placed and aggregate was present and compacted. They will be using KCMMB mix and white cure. RP 6-5-20
Driveway Inspection Passed 6/12/2020 6/12/2020 06/17/2020
Misc
Informational
06/05/2020
Forms were placed and aggregate was present and compacted. RP 6-5-20
Occupancy Inspection - Codes Residential Failed 7/28/2020 7/28/2020 07/28/2020
Misc
Corrective Action Required
07/28/2020
- Guard rail required at front porch, more than 30” from grade - Complete final grade and sod - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” - Terminate NM electrical at fireplace - Cover plates at all switches and receptacles - provide (2) 3” screws at strike plate back door to deck and basement walkout - Terminate NM electrical for lighting above kitchen island - Jacuzzi tub motor access required per code - flue and pex too close at water heater, follow manufacturer distance requirements - Safety glazing required at window in front bedroom within closet door plane per code R308.4.2
Plot Plan Inspection Passed 10/07/2020
Occupancy Inspection - Codes Residential Full C of O 10/7/2020 10/7/2020 10/07/2020
Misc
Resolved
10/07/2020
- Guard rail required at front porch, more than 30” from grade - Complete final grade and sod - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” - Terminate NM electrical at fireplace - Cover plates at all switches and receptacles - provide (2) 3” screws at strike plate back door to deck and basement walkout - Terminate NM electrical for lighting above kitchen island - Jacuzzi tub motor access required per code - flue and pex too close at water heater, follow manufacturer distance requirements - Safety glazing required at window in front bedroom within closet door plane per code R308.4.2
Documents & Images
Date Uploaded File Type Document Name
11/25/2019 Receipt Receipt for transaction: 2019-007455
11/25/2019 Plot Plan DOC112519-001
11/25/2019 Letter DS Building Permit
12/31/2019 Letter INSPECTION SUMMARY
12/31/2019 93110A0C-631F-4926-BE75-4C1FDDFA6F00
12/31/2019 551553CF-313D-4561-B124-0284FB29CCFE
12/31/2019 8064F21B-DD61-49FE-B360-280CAA071292
02/10/2020 Letter INSPECTION SUMMARY
04/08/2020 Letter INSPECTION SUMMARY
04/09/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/13/2020 Letter INSPECTION SUMMARY
05/14/2020 490499R1
05/14/2020 Lot 19 Creekside at Raintree - Framing Inspection Letter
05/19/2020 Letter INSPECTION SUMMARY
06/05/2020 Letter INSPECTION SUMMARY
06/05/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
07/28/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter Codes Final Certificate of Occupancy
10/07/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home