Permit Application Status

PRRES20193184


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193184
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT
10/29/2019
11/19/2019
12/04/2020
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/18/2019 11/19/2019
Steve Conrick
Waiting on MDP to be approved. Steven Conrick 11/01/2019 2:39 PM
Residential Plan Review Approved 10/30/2019 10/30/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,352.17 $1,352.17 Paid 11/19/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 11/19/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 11/19/2019
8331507-Sewer Connection Fee $630.00 $630.00 Paid 11/19/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/19/2019
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 11/19/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/01/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/13/2019 (1:00) 12/13/2019 12/13/2019
Sewer Service Inspection - R Passed 2/27/2020 2/27/2020 02/27/2020
Water Service Inspection - R Passed 2/28/2020 (1:00) 2/28/2020 02/28/2020
Underslab Plumbing Inspection - Residential Passed 2/28/2020 2/28/2020 02/28/2020
Piers/Caissons Inspection - Residential Passed 4/27/2020 (1:45) 4/27/2020 04/27/2020
Gas Piping Inspection - Residential Passed 6/15/2020 6/15/2020 06/15/2020
Gas Service Inspection - Residential Passed 6/15/2020 6/15/2020 06/15/2020
Electrical Service Inspection Failed 6/15/2020 6/15/2020 06/15/2020
Misc
Corrective Action Required
06/15/2020
- Color code ufer ground at service panel -
All Rough Inspection - Residential Failed 6/15/2020 6/15/2020 06/15/2020
Misc
Corrective Action Required
06/15/2020
- Fireblock HVAC/flue chase at pantry - Boca protection plate DWV at pantry, pex at 1st floor bath closet, laundry - Seal all top plate penetrations - Fireblock above fireplace - Joist hanger missing, 1st floor entry by bath - Properly nail all joist hangers at lvl connection living room - Truss hangers per plan in garage - Remove lid at front porch to allow inspection of all truss hangers - EC#2 800 lb hold down per plans - Truss bracing per plans - H2.5 truss straps missing 2nd floor - Complete connection HVAC duct 2nd floor, support ductwork per code - Support and protect pex at shower - color code ufer ground at panel - Anchor all columns to floor - Joist hangers required at joist connection to triple joist under fireplace in basement, more than 4’
Electrical Service Inspection Passed 6/19/2020 6/19/2020 06/19/2020
All Rough Inspection - Residential Failed 6/19/2020 6/19/2020 06/19/2020
Misc
Corrective Action Required
06/19/2020
- Strap top plate at DWV in pantry - Remove lid at front porch to allow inspection of all truss hangers - cannot inspect all truss hangers currently - EC#2 800 lb hold down per plans
All Rough Inspection - Residential Failed 6/23/2020 6/23/2020 06/23/2020
Misc
Corrective Action Required
06/19/2020
- Truss hanger missing front porch
Driveway Inspection Partial 6/24/2020 6/24/2020 06/24/2020
Misc
Informational
06/24/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 6/24/2020 6/24/2020 06/24/2020
Misc
Informational
06/24/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 6/29/2020 6/29/2020 06/29/2020
Sidewalk Inspection Passed 6/29/2020 6/29/2020 06/29/2020
All Rough Inspection - Residential Passed 7/7/2020 7/7/2020 07/07/2020
Misc
Resolved
07/07/2020
Occupancy Inspection - Codes Residential Failed 10/12/2020 10/12/2020 10/12/2020
Misc
Corrective Action Required
10/12/2020
-Post permanent address -Seal all penetrations in siding, seal along top of meter can and AC disconnect -Splash blocks at all downspout and sump pump discharge locations, minimum 36” discharge from foundation -Complete ceiling light fixture front entry hall -Remove paint covers from all smokes -Garage door must be self closing -GFCI protection required at washing machine receptacle -Complete light fixture at vanity 2nd floor bath -Access required to jacuzzi tub motor master bath -Cut floor joist above furnace for HVAC duct, header off floor joist -Gas service required for occupancy
Occupancy Inspection - Codes Residential Failed 11/24/2020 11/24/2020 11/24/2020
Misc
Corrective Action Required
11/24/2020
-Seal all penetrations in siding, seal along top of meter can and AC disconnect -Sump pump discharge minimum 36” from foundation -Remove paint covers from all smokes - basement -GFCI protection required at washing machine receptacle -Access required to jacuzzi tub motor master bath -Cut floor joist above furnace for HVAC duct, header off floor joist
Occupancy Inspection - Codes Residential Not Ready 11/25/2020 11/25/2020 11/25/2020
Misc
Corrective Action Required
11/24/2020
-Seal all penetrations in siding, seal along top of meter can and AC disconnect -Sump pump discharge minimum 36” from foundation -Remove paint covers from all smokes - basement -GFCI protection required at washing machine receptacle -Access required to jacuzzi tub motor master bath iNTERIOR ITEMS INCOMPLETE AT INSPECTION- RECALL WHEN READY
Occupancy Inspection - Codes Residential Failed 11/30/2020 11/30/2020 11/30/2020
Misc
Corrective Action Required
11/25/2020
-LOCATE ELECTRICAL RECEPTACLE FOR JACUZZI TUB PUMP MOTOR IN MASTER BATH, TEST OF GFCI REQUIRED - RESOLVE OUTSTANDING INSPECTION FEE BEFORE FINAL C OF O iNTERIOR ITEMS INCOMPLETE AT INSPECTION- RECALL WHEN READY
Erosion Control Inspection Residential Passed 12/04/2020
Plot Plan Inspection Passed 12/04/2020
Occupancy Inspection - Codes Residential Full C of O 12/4/2020 12/4/2020 12/04/2020
Misc
Resolved
12/04/2020
Documents & Images
Date Uploaded File Type Document Name
11/19/2019 Receipt Receipt for transaction: 2019-007379
11/19/2019 Letter DS Building Permit
11/21/2019 Plot Plan DOC112019-11202019153920
12/13/2019 Letter INSPECTION SUMMARY
02/27/2020 Letter INSPECTION SUMMARY
02/28/2020 Letter INSPECTION SUMMARY
02/28/2020 Letter INSPECTION SUMMARY
04/27/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/15/2020 Letter INSPECTION SUMMARY
06/19/2020 Letter INSPECTION SUMMARY
06/19/2020 Letter INSPECTION SUMMARY
06/23/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
06/29/2020 Letter INSPECTION SUMMARY
07/07/2020 Letter INSPECTION SUMMARY
10/12/2020 Letter INSPECTION SUMMARY
11/24/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
12/01/2020 Receipt Receipt for transaction: 2020-007777
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter INSPECTION SUMMARY
12/04/2020 Letter Field Certificate of Occupancy
12/04/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home