Summary
PRRES20192858
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - UNFINISHED BASEMENT
10/02/2019
10/14/2019
08/07/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/07/2019 10/14/2019
Development Center
As-graded plot plan
Corrective Action Required
10/03/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Drainage swales
Corrective Action Required
10/03/2019

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide
Planning Review (RES) Approved 10/07/2019 10/09/2019
Dylan Eppert
Residential Plan Review Approved 10/07/2019 10/03/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,284.17 $1,284.17 Paid 10/14/2019
8331507-Sewer Connection Fee $600.00 $600.00 Paid 10/14/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 10/14/2019
Water Meter Fee $425.02 $425.02 Paid 10/14/2019
Right of Way Permit Fee $80.00 $80.00 Paid 10/14/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/14/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 10/25/2019 10/25/2019 10/25/2019
Misc
Corrective Action Required
10/25/2019
No plans on site No address posted
Footing Inspection - Residential Passed 10/25/2019
Misc
Resolved
10/25/2019
Underslab Plumbing Inspection - Residential Failed 11/22/2019 11/22/2019 11/22/2019
Misc
Corrective Action Required
11/22/2019
No site with this address ready for underslab inspection.
Underslab Plumbing Inspection - Residential Passed 11/26/2019 11/26/2019 11/26/2019
Misc
Resolved
11/26/2019
Piers/Caissons Inspection - Residential Passed 2/18/2020 (8:15) 2/18/2020 02/18/2020
Misc
Corrective Action Required
02/18/2020
(3) 24 x 36
Sewer Service Inspection - R Passed 2/25/2020 2/25/2020 02/25/2020
Water Service Inspection - R Passed 2/26/2020 2/26/2020 02/26/2020
Gas Piping Inspection - Residential Passed 4/15/2020 4/15/2020 04/15/2020
Gas Service Inspection - Residential Passed 4/15/2020 04/15/2020
Electrical Service Inspection Failed 4/15/2020 4/15/2020 04/15/2020
ELECTRICAL
Corrective Action Required
04/15/2020
- REMOVE BONDING SCREW FROM SUB PANEL -
All Rough Inspection - Residential Failed 4/15/2020 4/15/2020 04/15/2020
Misc
Corrective Action Required
04/15/2020
-ELECTRICAL - - REMOVE BONDING SCREW FROM SUB PANEL - - PROVIDE ANCHOR BOLTS AT PLATE BREAKS GARAGE & BASEMENT - -TIGHTEN ANCHOR BOLTS BASEMENT - - PROVIDE 2 ANCHOR BOLTS SCH 40 COLUMN GARAGE- - PROVIDE H 2.5s TRUSSES FLEX ROOM - - SEAL BORES IN TOP PLATE CHASE NEAR 20 MIN DOOR - - FRAMING AT AIR RETURN 2ND STORY HALLWAY - - FIRE BLOCK DEAD SPACE NEAR BATH FRONT BEDROOM - - EC#2 PROVIDE 800 LB HOLD DOWNS THROUGHOUT PER PLAN - - PROVIDE BLOCKING FOR TRUSS HANGERS ABOVE REFRIGERATOR - - PROVIDE DBL 2 X 10 JOIST IN GARAGE NEAR MASTER CLOSET PER PLAN - - REPLACE BROKEN STUD UNDER STAIRWAY - - STRAP HEADERS AT STAIRWAY NOTCHED FOR HVAC - - PROVIDE PFH PORTAL FRAMING AT GARAGE DOOR PER PLAN - - ADDRESS BEAM IN BASEMENT CORNER NEAR WINDOWS (3) 2 X 6 STUD PACK -
All Rough Inspection - Residential Failed 4/21/2020 4/21/2020 04/21/2020
Misc
Corrective Action Required
04/15/2020
-ELECTRICAL - - REMOVE BONDING SCREW FROM SUB PANEL - -TIGHTEN ANCHOR BOLTS BASEMENT - - seal DEAD SPACE NEAR BATH FRONT BEDROOM - - EC#2 PROVIDE 800 LB HOLD DOWNS Upper level PER PLAN - - ADDRESS BEAM IN BASEMENT CORNER NEAR WINDOWS (3) 2 X 6 STUD PACK lands on 2 one of which 1/2 lands on bottom plate -
Electrical Service Inspection Failed 4/21/2020 4/21/2020 04/21/2020
ELECTRICAL
Corrective Action Required
04/15/2020
- REMOVE GREEN BONDING SCREW FROM SUB PANEL -
Electrical Service Inspection Passed 4/24/2020 4/24/2020 04/24/2020
ELECTRICAL
Resolved
04/24/2020
All Rough Inspection - Residential Passed 4/24/2020 4/24/2020 04/24/2020
Misc
Resolved
04/24/2020
Occupancy Inspection - Codes Residential Failed 6/24/2020 6/24/2020 06/24/2020
Misc
Corrective Action Required
06/24/2020
- Submit as graded plot plan for review - Obtain lawn irrigation system permit - Complete final grade and sod - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36” - Guardrail required at front porch, more than 30” from grade - Smoke detector required outside of front sleeping room in close vicinity, within 10’ - Set attic access cover in garage
Occupancy Inspection - Codes Residential Failed 8/6/2020 8/6/2020 08/06/2020
Misc
Corrective Action Required
06/24/2020
- Submit as graded plot plan for review
Driveway Inspection Passed 5/14/2020 5/14/2020 08/06/2020
Misc
Informational
05/14/2020
On Thursday, 5-14-2020. I performed a driveway inspection and found sub-grade and forming that meet city standards. Inspection passes.
Misc
Informational
08/06/2020
The driveway has passed inspeciton.
Plot Plan Inspection Passed 8/7/2020 08/07/2020
Occupancy Inspection - Codes Residential Full C of O 08/07/2020
Misc
Resolved
08/07/2020
Documents & Images
Date Uploaded File Type Document Name
10/09/2019 Letter Codes Residential Plan Review
10/14/2019 Receipt Receipt for transaction: 2019-006759
10/14/2019 Letter DS Building Permit
10/14/2019 Plot Plan DOC101419-005
10/25/2019 Letter INSPECTION SUMMARY
10/25/2019 Letter INSPECTION SUMMARY
11/22/2019 Letter INSPECTION SUMMARY
11/26/2019 Letter INSPECTION SUMMARY
02/18/2020 Letter INSPECTION SUMMARY
02/25/2020 Letter INSPECTION SUMMARY
02/26/2020 Letter INSPECTION SUMMARY
04/15/2020 Letter INSPECTION SUMMARY
04/15/2020 Letter INSPECTION SUMMARY
04/15/2020 Letter INSPECTION SUMMARY
04/15/2020 Letter INSPECTION SUMMARY
04/21/2020 Letter INSPECTION SUMMARY
04/21/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter INSPECTION SUMMARY
04/24/2020 Letter INSPECTION SUMMARY
04/24/2020 42 Hawthorne Ridge Braced Wall Panel Letter
06/24/2020 Letter INSPECTION SUMMARY
06/24/2020 Letter INSPECTION SUMMARY
08/06/2020 Letter INSPECTION SUMMARY
08/06/2020 Plot Plan APPROVED AS-BUILT
08/06/2020 Letter DE-Daily Inspection Summary
08/07/2020 Letter INSPECTION SUMMARY
08/07/2020 Letter Field Certificate of Occupancy
08/07/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home