Permit Application Status

PRRES20192617


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20192617
Building Permit - Residential
Certificate of Occupancy
MONTICELLO HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - PARTIAL FINISHED BASEMENT ***ROOF TRUSS PACKAGE AND I JOIST PACKAGE HAVE BEEN DEFFERRED AND WERE RECEIVED 11-25-19***
09/13/2019
09/23/2019
06/19/2020
Locations
Contacts
MONTICELLO HOMES INC, Address:623 NE LONE HILL DR  
MONTICELLO HOMES INC, Address:PO BOX 7005, Phone:(816) 478-4740  
ANDREAPETERSON@COMCAST.NET  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
HATHEWAY ELECTRIC LLC, Address:3125 SW PRYOR RD, Phone:(660) 232-2419  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 09/17/2019 09/20/2019
Dylan Eppert
Property boundary
Corrective Action Required
09/13/2019

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. WEST SIDE OF LOT SHOWS 68.87' BUT THE PLAT SHOWS 83'
Basement egress
Corrective Action Required
09/13/2019

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. LOCATION OF EGRESS WELLS CONFLICT WITH BUILDING PLANS PLEASE VERIFY LOCATIONS.
Spot elevations
Corrective Action Required
09/13/2019

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. PROVIDE ELEVATIONS FOR HIGH POINTS ON LOT.
Residential Plan Review Approved with Conditions 09/17/2019 09/20/2019
Dylan Eppert
06 Designate use of each room or space
Corrective Action Required
09/13/2019

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. CONSTRUCTION DRAWINGS ARE CONFLICTING WITH COVERED DECK OR COVERED PATIO. PG A2 SHOWS COVERED PATIO 129 SQ FEET BUT PAGE A2 CALLS OUT COVERED DECK PLEASE CLARIFY.
Miscellaneous Correction
Corrective Action Required
09/13/2019

CONSTRUCTION DRAWINGS REFERENCE 2012 BUILDING CODE. AS OF APRIL 1ST 2019 WE HAVE ADOPTED THE 2018 BUILDING CODE.
18 Identify type of roof/truss package (if used) complete with layout, comp
Corrective Action Required
09/13/2019

Identify type of roof/truss package (if used) complete with layout, component design, fastening details, blocking and sheathing requirements. (IRC Section 802.10) IS ROOF TRUSS PACKAGE BEING DEFFERED?
30 Identify type of protection used in unfinished areas under
Corrective Action Required
09/13/2019

Identify type of protection used in unfinished areas under floor trusses. (IRC Section R501.3)
31 Identify type of joist package or floor truss package (if used)
Corrective Action Required
09/13/2019

Identify type of joist package or floor truss package (if used) complete with layouts, fastening details, blocking and bracing requirements and minimum sheathing. IS I JOIST PACKAGE BEING DEFFERED?
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,242.55 $1,242.55 Paid 09/23/2019
8331507-Sewer Connection Fee $450.00 $450.00 Paid 09/23/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 09/23/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 09/23/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/23/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 09/23/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Passed 9/24/2019 09/24/2019
Informational
09/24/2019
-EROSION CONTROL IS IN COMPLIANCE. MAINTAIN EROSION CONTROL UNTIL SODDING
Footing Inspection - Residential Failed 9/25/2019 9/24/2019 at 1:15 PM 09/24/2019
Misc
Corrective Action Required
09/24/2019
-THE TWO EAST 48" PADS MUST BE MIN 16" THICK -INSTALL GRADE BEAM PER PLAN
Footing Inspection - Residential Passed 09/27/2019
Misc
Resolved
09/27/2019
-THE TWO EAST 48" PADS MUST BE MIN 16" THICK -INSTALL GRADE BEAM PER PLAN
Underslab Plumbing Inspection - Residential Passed 10/4/2019 10/4/2019 at 9:35 AM 10/04/2019
Sewer Service Inspection - R Passed 10/4/2019 at 1:30 PM 10/04/2019
Water Service Inspection - R Partial 10/4/2019 10/04/2019
Water Service Inspection - R Passed 10/7/2019 (1:00) 10/7/2019 at 1:10 PM 10/07/2019
Piers/Caissons Inspection - Residential Passed 10/31/2019 at 1:15 PM 10/31/2019
Gas Service Inspection - Residential Passed 1/10/2020 1/10/2020 01/10/2020
Electrical Service Inspection Passed 1/10/2020 1/10/2020 01/10/2020
All Rough Inspection - Residential Failed 1/10/2020 1/10/2020 01/10/2020
Misc
Corrective Action Required
01/10/2020
Provide 3 studs between windows flex,dining,master per plan detail 3 Provide anchor bolt rear wall behind wet dar Tighten anchor bolt steel col;umn under stairs
All Rough Inspection - Residential Passed 1/16/2020 1/16/2020 at 11:10 AM 01/16/2020
Misc
Informational
01/16/2020
Just as an FYI. You should do the below: -Protect plumbing throughout, mostly in basement bathrooms -Stud shoe for studs bored than 60% -Nail the girder truss together per truss detail -Fb wall in basement from soffit -Bonding connection of gas piping need to be accessible I also saw a Dewalt saw out on the floor. I put the tool in the tub out-of-sight.
Driveway Inspection Partial 3/27/2020 3/27/2020 03/27/2020
Misc
Informational
03/27/2020
Driveway was formed with compacted rock. Ready to pour.
Sidewalk Inspection Partial 3/27/2020 3/27/2020 03/27/2020
Misc
Informational
03/27/2020
Sidewalked is formed with compacted rock, and appears to meet all ADA requirements. Ready to pour.
Occupancy Inspection - Codes Residential Failed 6/12/2020 6/12/2020 06/12/2020
Miscellaneous Correction
Corrective Action Required
06/12/2020
Miscellaneous Correction
Corrective Action Required
06/12/2020
-SEAL ALL EXTERIOR PENETRATIONS -PROVIDE PROPER DRAINAGE AWAY FROM FOUNDATION FOR SUMP DISCHARGE -PROVIDE GFCI IN LAUNDRY ROOM -PROVIDE GFCI PROTECTION FOR DISHWASHER -REMOVE SET SCREW IN ANTI SYPHON DEVICE -PROVIDE EGRESS LADDERS FOR WINDOW WELLS -COMPLETE MINERAL WOOL OVER DUCTWORK IN NORTH UNFINISHED BASEMENT
Occupancy Inspection - Codes Residential Temporary C of O 6/17/2020 6/17/2020 at 10:05 AM 06/17/2020
Miscellaneous Correction
Resolved
06/17/2020
Miscellaneous Correction
Corrective Action Required
06/12/2020
-LAG SCREW THE DECK LEDGER BOARD INTO RIM BAND PER CODE -COMPLETE MINERAL WOOL OVER DUCTWORK IN NORTH UNFINISHED BASEMENT **THROUGHOUT-INSTALL THE MINERAL WOOL TO BOTTOM OF THE TJI WEB. INSTALL SUPPORT WIRES REQUIRED PER PRODUCT INSTRUCTION -PROVIDE AFCI PROTECTION PER NEC 210.12. ALL OUTLETS LOCATED IN AREAS BESIDE CRAWL SPACE, UNFINISHED BASEMENT, OUTDOOR, ATTIC, GARAGE, AND BATHROOM ARE REQUIRED TO BE AFCI-PROTECTED -THE RECEPTACLE AT SUBPANEL NOT GFCI
Sidewalk Inspection Passed 3/31/2020 06/17/2020
Misc
Informational
03/27/2020
Sidewalked is formed with compacted rock, and appears to meet all ADA requirements. Ready to pour.
Misc
Informational
06/17/2020
Sidewalk - passed inspection
Driveway Inspection Passed 3/31/2020 06/17/2020
Misc
Informational
03/27/2020
Driveway was formed with compacted rock. Ready to pour.
Misc
Informational
06/17/2020
Driveway - passed inspection.
Occupancy Inspection - Codes Residential Full C of O 6/19/2020 6/19/2020 at 2:25 PM 06/19/2020
Miscellaneous Correction
Resolved
06/19/2020
-LAG SCREW THE DECK LEDGER BOARD INTO RIM BAND PER CODE -COMPLETE MINERAL WOOL OVER DUCTWORK IN NORTH UNFINISHED BASEMENT **THROUGHOUT-INSTALL THE MINERAL WOOL TO BOTTOM OF THE TJI WEB. INSTALL SUPPORT WIRES REQUIRED PER PRODUCT INSTRUCTION -PROVIDE AFCI PROTECTION PER NEC 210.12. ALL OUTLETS LOCATED IN AREAS BESIDE CRAWL SPACE, UNFINISHED BASEMENT, OUTDOOR, ATTIC, GARAGE, AND BATHROOM ARE REQUIRED TO BE AFCI-PROTECTED -THE RECEPTACLE AT SUBPANEL NOT GFCI
Documents & Images
Date Uploaded File Type Document Name
09/13/2019 Letter Codes Residential Plan Review
09/23/2019 Letter DS Building Permit
09/23/2019 Receipt Receipt for transaction: 2019-006350
09/23/2019 Plot Plan DOC092319-09232019094630
09/24/2019 Letter INSPECTION SUMMARY
09/24/2019 Letter INSPECTION SUMMARY
09/27/2019 Letter INSPECTION SUMMARY
10/04/2019 Letter INSPECTION SUMMARY
10/04/2019 Letter INSPECTION SUMMARY
10/04/2019 Letter INSPECTION SUMMARY
10/07/2019 Letter INSPECTION SUMMARY
10/31/2019 Letter INSPECTION SUMMARY
01/10/2020 Letter INSPECTION SUMMARY
01/10/2020 Letter INSPECTION SUMMARY
01/10/2020 Letter INSPECTION SUMMARY
01/16/2020 Engineer Report/Study 2020-01-13 Rough-in Inspection
01/16/2020 Letter INSPECTION SUMMARY
03/27/2020 Letter DE-Daily Inspection Summary
03/27/2020 Letter DE-Daily Inspection Summary
06/03/2020 Sprinkler Layout 2013 Bluestone
06/12/2020 Letter INSPECTION SUMMARY
06/12/2020 Letter INSPECTION SUMMARY
06/12/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter Codes Temporary Certificate of Occupancy
06/17/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
06/19/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home