Review Type |
Outcome |
Est. Completion Date |
Completed |
Residential Plan Review
|
Approved
|
09/13/2019
|
09/20/2019
|
|
Dylan Eppert
|
|
06 Designate use of each room or space
Corrective Action Required
Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space.
SHEET 5 - NEED GARAGE, REC ROOM, BEDROOM (WITH SMOKE AND CO DETECTOR), UNFINISHED AREA
|
|
07 Identify emergency escape openings from bedrooms
Corrective Action Required
Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
BEDROOM 3 NEEDS EGRESS LABEL ON SHEET 6
|
|
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
BASEMENT BEDROOM NEEDS SMOKE AND COMBO DETECTOR LEBELED
|
|
17 Specification of rafter ties or ridge beam design.
Corrective Action Required
Specification of rafter ties or ridge beam design. (IRC Section 802.3.1)
|
|
19 Footings, column pads, piers and grade beams - dimensions
Corrective Action Required
Footings, column pads, piers and grade beams - dimensions. (IRC Section R403)
CALL OUT COLUMN PADS IN GARAGE AND DIMENSIONALLY LOCATE ON PLANS
|
|
27 Provide size, spacing, species and grade of dimensional floor joists.
Corrective Action Required
Provide size, spacing, species and grade of dimensional floor joists.
IDENTIFY SPECIES OF FLOOR JOISTS
|
|
15 Provide size, spacing, species, and grade of rafter, ceiling joist mater
Corrective Action Required
Provide size, spacing, species, and grade of rafter, ceiling joist materials and ridge and valley members. (IRC Section R802)
IDENTIFY SPECIES OF RAFTERS
|
|
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
|
|
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304)
PROVIDE SQFT FOR COVERED PATIO
|
|
|
Plot Plan Review
|
Approved
|
09/13/2019
|
09/20/2019
|
|
Dylan Eppert
|
|
As-graded plot plan
Corrective Action Required
A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
|
|
City infrustructure
Corrective Action Required
Show all manholes, water valve boxes, fire hydrants, and stormwater structures.
MISSING FH AND VALVE
|
|
Basement egress
Corrective Action Required
Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan.
PLOT PLAN SHOWS 2 EGRESS WELLS AND THE CONSTRUCTION DRAWINGS SHOW 3 AS WELL AS LAG NOT FOUND PLEASE VERIFY.
|
|
|