Permit Application Status

PRRES20192214


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20192214
Building Permit - Residential
Certificate of Occupancy
BILL KENNEY HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED DECK - LAWN IRRIGATION
08/14/2019
09/05/2019
12/03/2020
Locations
Contacts
BILL KENNEY HOMES INC, Address:PO BOX 291  
BILL KENNEY & ASSOCIATES, Address:P O BOX 291, Phone:(816) 838-0552  
BILLKENNEY9@GMAIL.COM  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
ONHOME SYSTEMS LLC, Address:510 SW MISSION RD, Phone:(816) 875-3696  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 08/16/2019 09/05/2019
Development Center
06 Designate use of each room or space
Corrective Action Required
08/16/2019

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. LUANDRY ROOM IS NOT LABELED, BATHROOM ON MAIN FLOOR PLAN NOT LABELED, BATHROOM ON FOUNDATION PLAN NOT LABELED, BATHROOM ON LOWER LEVEL NOT LABELED. ARE YOU PURPOSING 1.5 BATHS ON THE LOWER LEVEL NEED CLARIFICATION.
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
08/16/2019

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) ON COVER PAGE YOU HAVE BASEMENT SQUARE FOOTAGE LISTED AS 1520. THIS DOESN'T MAKE SINCE WITH THE APPLICATION SUBMITTED.
Planning Review (RES) Approved 08/26/2019 08/23/2019
Jennifer Thompson
Plot Plan Review Approved 08/16/2019 08/21/2019
Steve Conrick
City infrustructure
Corrective Action Required
08/16/2019

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. *Missing mh of junction box
As-graded plot plan
Corrective Action Required
08/16/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Add "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $900.48 $900.48 Paid 09/05/2019
8331507-Sewer Connection Fee $360.00 $360.00 Paid 09/05/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 09/05/2019
Water Meter Fee $425.02 $425.02 Paid 09/05/2019
Right of Way Permit Fee $80.00 $80.00 Paid 09/05/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/05/2019
Additional Permit Fee $30.00 $30.00 Paid 09/05/2019
Not Ready Inspection Fee $50.00 $50.00 Paid 01/16/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/24/2019 9/24/2019 09/24/2019
Sewer Service Inspection - R Passed 10/16/2019 10/16/2019
Misc
Informational
10/16/2019
Sewer is passed, install erosion control and protect storm inlet before any further inspections
Erosion Control Inspection Residential Failed 10/23/2019 10/16/2019
Misc
Corrective Action Required
10/16/2019
install erosion control and protect storm inlet before any further inspections
Underslab Plumbing Inspection - Residential Passed 10/23/2019 10/23/2019 10/23/2019
Erosion Control Inspection Residential Failed 10/25/2019 10/25/2019
Misc
Corrective Action Required
10/16/2019
install erosion control and protect storm inlet before any further inspections
All Rough Inspection - Residential Failed 1/6/2020 01/06/2020
Misc
Corrective Action Required
01/06/2020
-install erosion control before any future inspections -over bored exteior studs, left of kitchen sink - protect electrical wires in laundry room at bottom plate, north wall - loose hold down nuts throughout garage - hold down bolts must be installed in the middle third of plate, install where needed in throughout garage - fire block master bathroom penetrations through subfloor - protect waterline at top plate, throughout basement bathroom - fireblock double walls vertically in basement per code - fireblock south double wall at top plate where piping goes through - hold down bolts need to be installed within middle third of plate in basement, install bolts where needed, loose hold down bolts throughout basement - support fir out ceiling in basement every 3’ - fire block underneath 1st level spare bathtub Do not insulate
Electrical Service Inspection Passed 1/6/2020 01/06/2020
Gas Service Inspection - Residential Passed 1/6/2020 01/06/2020
All Rough Inspection - Residential Failed 1/13/2020 1/13/2020 01/13/2020
Misc
Corrective Action Required
01/06/2020
-install erosion control before any future inspections - protect electrical wires in laundry room at bottom plate, north wall, * 3” plate required - loose hold down nuts throughout garage and basement - protect waterline at top plate, throughout basement bathroom * must be protected 3” - fireblock double walls vertically in basement per code *solid blocking needed, loose insulation not allowed for current width span - support fir out ceiling in basement every 3’ - fire block underneath 1st level spare bathtub - address notched floor joist on south end where pipe goes through - fireblock deadspace in south side basement Do not insulate
Erosion Control Inspection Residential Failed 01/13/2020
Misc
Corrective Action Required
10/25/2019
install erosion control and protect storm inlet before any further inspections
All Rough Inspection - Residential Not Ready 1/15/2020 01/15/2020
Misc
Corrective Action Required
01/13/2020
-install erosion control before any future inspections - protect electrical wires in laundry room at bottom plate, north wall, * 3” plate required - protect waterline at top plate, throughout basement bathroom * must be protected 3” - fireblock double walls vertically in basement per code *solid blocking needed, loose insulation not allowed for current width span - support fir out ceiling in basement every 3’ - fire block underneath 1st level spare bathtub - address notched floor joist on south end where pipe goes through - fireblock deadspace in south side basement Do not insulate Not ready fee assessed
All Rough Inspection - Residential Passed 1/23/2020 1/23/2020 01/23/2020
Misc
Resolved
01/23/2020
Ok to insulate
Piers/Caissons Inspection - Residential Passed 2/19/2020 (11:00) 2/19/2020 02/19/2020
Water Service Inspection - R Passed 2/27/2020 2/27/2020 02/27/2020
Driveway Inspection Passed 04/01/2020
Misc
Informational
03/31/2020
Checked Sub-grade, Forms and Rock Fill. Everything passes. Will stop by tomorrow to check finish for total accceptence.
Misc
Informational
04/01/2020
On Wednesday, 4-01-2020 I completed visual inspection of driveway. Finish meets standard specification and passes inspection.
Erosion Control Inspection Residential Passed 09/04/2020
Plot Plan Inspection Passed 9/4/2020 09/04/2020
Sidewalk Inspection Passed 3/31/2020 (P.M.) 3/31/2020 09/09/2020
Misc
Informational
09/09/2020
A visual field inspection was conducted on 9-09-2020 and it was determined the sidewalk passes inspection.
Occupancy Inspection - Codes Residential Failed 11/30/2020 11/30/2020 11/30/2020
Misc
Corrective Action Required
11/30/2020
-Cover plate at basement bar receptacle -Label all dedicated receptacles in garage and unfinished basement as not GFCI protected -Sump pump discharge minimum 36” from foundation -Joist hager angel clip at dbl joist connection to ledger -Max overcurrent protection for AC compressor 35 amps
Occupancy Inspection - Codes Residential Full C of O 12/3/2020 12/3/2020 12/03/2020
Misc
Resolved
12/03/2020
Documents & Images
Date Uploaded File Type Document Name
08/16/2019 Letter Codes Residential Plan Review
08/16/2019 Letter Codes Residential Plan Review
09/05/2019 Receipt Receipt for transaction: 2019-006053
09/05/2019 Letter DS Building Permit
09/11/2019 Plot Plan DOC091119-09112019083352
09/11/2019 Engineer Report/Study DOC091119-09112019083421
09/11/2019 Right of Way Form DOC091119-09112019083427
09/11/2019 Plot Plan DOC091119-09112019083442
09/24/2019 Letter INSPECTION SUMMARY
10/16/2019 Letter INSPECTION SUMMARY
10/16/2019 Letter INSPECTION SUMMARY
10/23/2019 Letter INSPECTION SUMMARY
10/25/2019 Letter INSPECTION SUMMARY
01/06/2020 Letter INSPECTION SUMMARY
01/06/2020 Letter INSPECTION SUMMARY
01/06/2020 Letter INSPECTION SUMMARY
01/13/2020 Letter INSPECTION SUMMARY
01/13/2020 Letter INSPECTION SUMMARY
01/15/2020 Letter INSPECTION SUMMARY
01/16/2020 Receipt Receipt for transaction: 2020-000205
01/23/2020 Letter INSPECTION SUMMARY
02/19/2020 Letter INSPECTION SUMMARY
02/27/2020 Letter INSPECTION SUMMARY
09/03/2020 Plot Plan APPROVED AS-BUILT
09/04/2020 Letter INSPECTION SUMMARY
09/04/2020 Letter INSPECTION SUMMARY
09/04/2020 Letter INSPECTION SUMMARY
09/04/2020 Letter INSPECTION SUMMARY
11/30/2020 Letter INSPECTION SUMMARY
12/03/2020 Letter Field Certificate of Occupancy
12/03/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home