Summary
PRRES20192138
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED PATIO
08/08/2019
08/09/2019
07/30/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/12/2019 08/09/2019
Steve Conrick
Residential Plan Review Approved 08/12/2019 08/08/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $969.83 $969.83 Paid 08/09/2019
8331507-Sewer Connection Fee $360.00 $360.00 Paid 08/09/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 08/09/2019
Water Meter Fee $425.02 $425.02 Paid 08/09/2019
Right of Way Permit Fee $80.00 $80.00 Paid 08/09/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/09/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/5/2019 (1:45) 9/5/2019 09/05/2019
Sewer Service Inspection - R Passed 9/19/2019 09/19/2019
Water Service Inspection - R Passed 9/20/2019 9/20/2019 09/20/2019
Underslab Plumbing Inspection - Residential Passed 10/15/2019 10/15/2019 10/15/2019
Piers/Caissons Inspection - Residential Passed 10/30/2019 (10:45) 10/30/2019 10/30/2019
Electrical Service Inspection Passed 3/18/2020 3/18/2020 03/18/2020
Gas Piping Inspection - Residential Passed 3/18/2020 3/18/2020 03/18/2020
Gas Service Inspection - Residential Passed 3/18/2020 03/18/2020
All Rough Inspection - Residential Failed 3/18/2020 3/18/2020 03/18/2020
Misc
Corrective Action Required
03/18/2020
>Fire stop above pane. >fire stop basement walls at windows, also 10' horizontal. > flat ceiling Joist over 3 feet. >Plumbing protection at vent for basement east bathroom at 2 x 4 block. > Romex in contact with flue furnace room. > Support DWV unfinished basement. <>Joist framing not deviates from plans. Revise plans to show header and joist change. Header bored for electrical multiple places , provide engineers report. 1st floor. >--flue clearance to wall and sheet rock needs to be 1 inch to combustible. >Flue clearance to plywood at roof deck. > combustion air for basement, plans show 90%. Location of furnace changed. > loose insulation in dead space not approved solid block or three-quarter inch plywood, bathroom off of the front hallway .>EC #2 straps missing at walls, >Patio 6X6 poured in concrete. >Install nail Protection Plate Top Of Wall Master vanity At Ceiling Height. >Missing plate bolts front wall garage ,correct all notched studs for plate bolts 4 locations in garage. > nail all dbl truss per plans.
All Rough Inspection - Residential Failed 3/23/2020 3/23/2020 03/23/2020
Misc
Corrective Action Required
03/18/2020
> combustion air for basement, plans show 90%. Location of furnace changed. > Provide hi/lo vents = CHECK ON FINAL
Plot Plan Inspection Passed 6/12/2020 06/12/2020
Driveway Inspection Passed 3/4/2020 3/4/2020 07/20/2020
Misc
Informational
03/04/2020
Forms were placed and aggregate was present. Needs more aggregate and compacted. Curbing needs to be patched. RP 3-4-20
Misc
Informational
07/20/2020
On 7-20-2020. A visual inspection was performed on the driveway and was found to meet standards and passed inspection.
Occupancy Inspection - Codes Residential Failed 7/20/2020 7/20/2020 07/20/2020
Misc
Corrective Action Required
07/20/2020
- Resolve outstanding items from all rough inspection - Switch plate cover at furnace switch - High / low vent for furnace combustion air required - Secure AC disconnect electrical whip to house from laying across grade
All Rough Inspection - Residential Passed 07/21/2020
Misc
Resolved
07/21/2020
Occupancy Inspection - Codes Residential Failed 07/21/2020
Misc
Corrective Action Required
07/20/2020
- Switch plate cover at furnace switch - High / low vent for furnace combustion air required - Secure AC disconnect electrical whip to house from laying across grade - Gas meter is buried
Occupancy Inspection - Codes Residential Full C of O 7/30/2020 7/30/2020 07/30/2020
Misc
Resolved
07/30/2020
Documents & Images
Date Uploaded File Type Document Name
08/09/2019 Receipt Receipt for transaction: 2019-005478
08/09/2019 Letter DS Building Permit
08/14/2019 Plot Plan DOC081219-08122019141145
09/05/2019 Letter INSPECTION SUMMARY
09/19/2019 Letter INSPECTION SUMMARY
09/20/2019 Letter INSPECTION SUMMARY
10/15/2019 Letter INSPECTION SUMMARY
10/30/2019 Letter INSPECTION SUMMARY
03/04/2020 Letter INSPECTION SUMMARY
03/18/2020 Letter INSPECTION SUMMARY
03/18/2020 Letter INSPECTION SUMMARY
03/18/2020 Letter INSPECTION SUMMARY
03/18/2020 Letter INSPECTION SUMMARY
03/23/2020 Letter INSPECTION SUMMARY
06/11/2020 LOT 100 ASBUILT
06/12/2020 Letter INSPECTION SUMMARY
07/20/2020 Letter INSPECTION SUMMARY
07/21/2020 Letter INSPECTION SUMMARY
07/21/2020 Letter INSPECTION SUMMARY
07/30/2020 Letter Field Certificate of Occupancy
07/30/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home