Summary
PRRES20191733
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
07/01/2019
07/15/2019
07/08/2020
Locations
Contacts
DAVE@DAVERICHARDSHOMES.COM  
BLUE VALLEY HEATING & COOLING LLC, Address:P O BOX 241, Phone:(816) 867-5122  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
DAVE RICHARDS HOMEBUILDING INC, Address:605 SW US HIGHWAY 40 #414, Phone:(816) 365-8034  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 07/03/2019 07/15/2019
Development Center
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
07/01/2019

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) A new detail sheet will be needed for page 1 with the correct square footages along with sheet 3 at the top left corner where it says "Area where Furnace and HW Heater are located showing 772 Square Feet."
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
07/01/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) Carbon Monixide dector will need to be located directly outside of Bedroom #3 on sheet 4.
Monticello Landscaping
Corrective Action Required
07/12/2019

Per Ordinance 7690, Section 3.10 The builders are required to put in a minimum of three Evergreen trees, two ornamental trees and three shrubs, on each lot adjacent to the Lake Ridge Meadows and Dalton's Ridge subdivisions, acknowledging that the goal is to provide a visual buffer for the property to the north. No final certificate of occupancy shall be issued for an individually affected lot until such time as the required number of trees and shrubs are planted on said lot. The required landscaping shall be planted within 20 feet of the rear proerty line. The required landscaping shall meet the minimum size requirements of the UDO at the time of planting (i.e. 8' for Evergreen trees, 3" caliper for ornamental trees and 2-gallon container for shrubs).
Plot Plan Review Approved 07/03/2019 07/01/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,092.79 $1,092.79 Paid 07/15/2019
8331507-Sewer Connection Fee $360.00 $360.00 Paid 07/15/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 07/15/2019
Water Meter Fee $425.02 $425.02 Paid 07/15/2019
Right of Way Permit Fee $80.00 $80.00 Paid 07/15/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/15/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 7/31/2019 (1:00) 7/31/2019 at 1:30 PM 07/31/2019
Water Service Inspection - R Passed 8/1/2019 (9:45) 8/1/2019 at 9:55 AM 08/01/2019
Underslab Plumbing Inspection - Residential Passed 8/5/2019 8/5/2019 08/05/2019
Gas Service Inspection - Residential Passed 10/14/2019 10/14/2019
Misc
Corrective Action Required
10/14/2019
-Complete gas connection to fireplace and pressure test
Electrical Service Inspection Passed 10/14/2019 10/14/2019
All Rough Inspection - Residential Failed 10/14/2019 10/14/2019 at 10:05 AM 10/14/2019
Misc
Corrective Action Required
10/14/2019
**SHALL REINSTALL EROSION CONTROL AT REAR OF LOT FRAMING: -Nail garage portal brace walls sheathing to sill plate -Fur out garage wall at return air space for R13 insulation -Install collar ties near ridge -Provide CSPF exterior brace walls at rear brace wall line per plan -Lag boards to I beam above kitchen -Have engineer address non-continuous studs at rear living room wall and joist bored within 2” of joist bottom by furnace pipes -Nail corner studs per code -Provide a bearing wall under master bedroom/living rm bearing wall -Solid block cantilevered master bedroom joists -Install minimum double stud support for double joist under front bathroom tub -Install joist hangers under front bathroom tub MECHANICAL: -Can no longer install dryer vent inside 2x4 wall under IRC 2018. Please provide min 4” depth wall space in future constructions -Complete framing and fasten fireplace to framing PLUMBING: -Protect laundry plumbing. Install stud shoe for over bored stud -Complete installing tub at bathroom ELECTRICAL: -Provide a rear outdoor receptacle readily accessible from and within 6.5 ft of grade -Staple wiring near attic access to running board -Secure wiring within 8” of master bathroom sink receptacle box -Secure wiring per code in master bedroom wall **OK TO INSULATE
Piers/Caissons Inspection - Residential Passed 10/14/2019 at 11:10 AM 10/14/2019
Erosion Control Inspection Residential Passed 10/18/2019 10/18/2019
Informational
10/18/2019
-EROSION CONTROL IS IN COMPLIANCE. MAINTAIN EROSION CONTROL UNTIL SODDING
All Rough Inspection - Residential Failed 10/18/2019 10/18/2019 at 9:05 AM 10/18/2019
Misc
Corrective Action Required
10/14/2019
FRAMING: -Provide CSPF exterior brace walls at rear brace wall line per plan **Get your engineer to address this -Have engineer address non-continuous studs at rear living room wall and joist bored within 2” of joist bottom by furnace pipes -Nail corner studs per code -Solid block cantilevered master bedroom joists -Install joist hangers under front bathroom tub **Nail the hanger PLUMBING: -Protect laundry plumbing. Install stud shoe for over bored stud -Complete installing tub at bathroom -Complete the gas line to the fireplace; protect the csst gas line; retest the gas piping system **OK TO INSULATE
Driveway Inspection Passed 10/14/2019 10/14/2019 10/23/2019
Misc
Informational
10/14/2019
Driveway- forms ad materials passed pre-inspection.
Misc
Informational
10/23/2019
Driveway passed final inspection.
All Rough Inspection - Residential Partial 11/8/2019 at 8:50 AM 11/08/2019
Misc
Corrective Action Required
10/18/2019
FRAMING: -Have engineer address non-continuous studs at rear living room wall and joist bored within 2” of joist bottom by furnace pipes **Support the joist per engineer letter item 3 **OK TO ROCK
All Rough Inspection - Residential Passed 11/20/2019 11/20/2019 11/20/2019
Misc
Resolved
11/20/2019
FRAMING: -Have engineer address non-continuous studs at rear living room wall and joist bored within 2” of joist bottom by furnace pipes **Support the joist per engineer letter item 3 **OK TO ROCK
Erosion Control Inspection Residential Failed 11/20/2019 11/20/2019 11/20/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/20/2019
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Passed 03/06/2020
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/06/2020
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 3/6/2020 at 10:35 AM 03/06/2020
Misc
Corrective Action Required
07/15/2019
**LANDSCAPING NOT MEETING THE REQUIREMENT PER CITY ORDINANCE ALONG THE REAR OF LOT **EROSION CONTROL SHALL BE ESTABLISHED PRIOR TO TCO ISSUANCE -Address -Final grade, sod, downspout and sump pump extensions -Locate sewer tracer wire and install sewer tracer port -Seal all exterior wall penetrations -Guardrail required at front stoop edge more than 30” above grade, as measured from 36” out from edge down to grade -Complete deck -Rear outdoor receptacle not gfci-protected -Move all items away from garage wall; complete lighting for garage -Remove all smoke alarms covers -Screw in the rear exterior door embedded brace into studs -Install box extensions for switch & receptacle boxes recessed more than 1/4” behind kitchen countertop backsplash -Install spark ring at floor receptacle -Fb floor penetrations -Remove all foundation wall ties -Seal return air space above basement -Secure wiring in basement per code -Bond gas piping. -Did the gas piping get rerouted to west side of the house? If so, the whole gas piping system needs to be retested -Intersystem bonding terminal bonding jumper is cut
Occupancy Inspection - Codes Residential Failed 7/6/2020 7/6/2020 at 9:05 AM 07/06/2020
Misc
Corrective Action Required
03/06/2020
-Address -Install sump pump extension -Seal all exterior wall penetrations -Screw in the rear exterior door embedded brace into studs -Remove all foundation wall ties -Intersystem bonding terminal bonding jumper is cut **check to make sure the jumper is not cut.
Occupancy Inspection - Codes Residential Failed 7/8/2020 7/8/2020 at 8:45 AM 07/08/2020
Misc
Corrective Action Required
07/06/2020
-Screw in the rear exterior door embedded brace into studs **Take a look at the deck door frame. There are 4 screw holes that are already pre-drilled: one hole 12" above and 12" below the strike plate and two behind the strike plate. Please use 3" screws and screw into these holes to secure the embedded brace into the jamb stud. Take a picture and send it to me.
Occupancy Inspection - Codes Residential Full C of O 7/8/2020 07/08/2020
Misc
Resolved
07/08/2020
-Screw in the rear exterior door embedded brace into studs **Take a look at the deck door frame. There are 4 screw holes that are already pre-drilled: one hole 12" above and 12" below the strike plate and two behind the strike plate. Please use 3" screws and screw into these holes to secure the embedded brace into the jamb stud. Take a picture and send it to me.
Documents & Images
Date Uploaded File Type Document Name
07/01/2019 Letter Codes Residential Plan Review
07/15/2019 Receipt Receipt for transaction: 2019-004793
07/15/2019 Letter DS Building Permit
07/18/2019 Plot Plan DOC071819-07182019080241
07/23/2019 Engineer Report/Study Garys Fndn 1313 NE Goshen Dr Lee's Summit Mo Footings 7-19-19
08/01/2019 Letter INSPECTION SUMMARY
08/05/2019 Letter INSPECTION SUMMARY
10/14/2019 Letter INSPECTION SUMMARY
10/14/2019 Letter INSPECTION SUMMARY
10/14/2019 Letter INSPECTION SUMMARY
10/14/2019 Letter INSPECTION SUMMARY
10/18/2019 Letter INSPECTION SUMMARY
10/18/2019 Letter INSPECTION SUMMARY
11/08/2019 Letter INSPECTION SUMMARY
11/20/2019 Letter INSPECTION SUMMARY
11/20/2019 Letter INSPECTION SUMMARY
11/20/2019 Letter INSPECTION SUMMARY
11/20/2019 Letter INSPECTION SUMMARY
03/06/2020 Letter INSPECTION SUMMARY
03/06/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter INSPECTION SUMMARY
07/08/2020 Letter Codes Final Certificate of Occupancy
07/08/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home