Permit Application Status

PRRES20191576


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20191576
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED PATIO/PORCH - PARTIAL FINISHED BASEMENT
06/17/2019
06/25/2019
05/07/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/19/2019 06/24/2019
Steve Conrick
As-graded plot plan
Corrective Action Required
06/19/2019

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. *Add "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING."
Residential Plan Review Approved 06/19/2019 06/17/2019
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,151.75 $1,151.75 Paid 06/25/2019
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/25/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 06/25/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 06/25/2019
8331504-EFHB Middle Big Creek, Full $468.72 $468.72 Paid 06/25/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 06/25/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 06/25/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/22/2019 7/22/2019 07/22/2019
Sewer Service Inspection - R Passed 8/9/2019 (9:15) 8/9/2019 at 9:30 AM 08/09/2019
Water Service Inspection - R Partial 8/9/2019 08/09/2019
Water Service Inspection - R Passed 8/9/2019 (2:15) 8/9/2019 at 3:30 PM 08/09/2019
Underslab Plumbing Inspection - Residential Passed 8/12/2019 8/12/2019 at 8:25 AM 08/12/2019
Gas Service Inspection - Residential Failed 10/25/2019 10/25/2019
Misc
Corrective Action Required
10/25/2019
**SEE ALLROUGH. RETEST WHEN READY
Electrical Service Inspection Passed 10/25/2019 10/25/2019
All Rough Inspection - Residential Failed 10/25/2019 10/25/2019 at 2:40 PM 10/25/2019
Misc
Corrective Action Required
10/25/2019
FRAMING: -Screw rear patio posts to roof beams against uplift -Garage exterior wall studs notched more than 25% -Strap the garage portal brace walls at inner sides -Install steel column for garage I beam and anchor to floor; complete furring around I beam -Fb duct chase from ceiling space; Fb rear living rm spaces from soffit -Install (3)2x4 support for lvl at stair -Install (3)2x4 stud support for lvl at front dining; fully nail hanger above -Install hangers for 3x joist at lvl connection above foyer; install hanger for adjacent joist -Nail 2x6 corner studs at stair per code -Provide roof ventilation per code -Fb basement wall vertically at max ten ft interval; Fb basement wall from soffits MECHANICAL: -Connect duct to bath fan 2nd fl bathroom ELECTRICAL: -Protect wiring within six ft of garage attic access -Protect home runs at master bedroom -Securely fasten wiring in basement ceiling fur-down, not resting on it -Smoke alarm in basement bedroom must be min 4” away from soffit wall -Provide proper clearance of light to storage space in basement bedroom closet per code PLUMBING: -Protect plumbing at kitchen duct chase -Protect gas csst line at fireplace -Gas line to fireplace located outside basement ceiling joist space. Redo gas line to fireplace and retest. Do not notch joist. -Clean out at bottom of waste stack located in basement family room shall be accessible **OK TO INSULATE
All Rough Inspection - Residential Failed 10/31/2019 10/31/2019 10/31/2019
Misc
Corrective Action Required
10/25/2019
FRAMING: -Install steel column for garage I beam and anchor to floor; complete furring around I beam -Fb duct chase from ceiling space; Fb rear living rm spaces from soffit -Nail 2x6 corner studs at stair per code -Provide roof ventilation per code ELECTRICAL: -Protect home runs at master bedroom PLUMBING: -Protect plumbing at kitchen duct chase -Protect gas csst line at fireplace -Gas line to fireplace located outside basement ceiling joist space. Redo gas line to fireplace and retest. Do not notch joist. **OK TO INSULATE
Gas Service Inspection - Residential Passed 10/31/2019 10/31/2019 10/31/2019
Misc
Resolved
10/31/2019
All Rough Inspection - Residential Failed 11/8/2019 11/8/2019 11/08/2019
Misc
Corrective Action Required
10/31/2019
PLUMBING: -Protect plumbing at kitchen duct chase -Gas line to fireplace located outside basement ceiling joist space. Redo gas line to fireplace and retest. Do not notch joist. **OK TO INSULATE
All Rough Inspection - Residential Passed 11/11/2019
Misc
Resolved
11/11/2019
Driveway Inspection Partial 12/23/2019 12/23/2019 12/23/2019
Misc
Informational
12/23/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 12/30/2019 01/02/2020
Misc
Informational
12/23/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 3/23/2020 3/23/2020 03/23/2020
Misc
Corrective Action Required
03/23/2020
- provide as graded plot plan - - provide final grade, sod, splash blocks - - provide covered deck pier inspections - - provide switch & receptacle cover plates Basement bedroom & bottom of stairs - - provide cover attic access laundry room - - shear off set screw anti siphon device - - GFCI mechanical room not working - - provide cover plates at kitchen counter - - provide (2) 3” screws each exterior hinge & strike plate- - seal exterior light fixtures - - GFCI exterior HVAC equipment not working -
Occupancy Inspection - Codes Residential Temporary C of O 3/27/2020 3/27/2020 03/27/2020
Miscellaneous Correction
Corrective Action Required
03/23/2020
Provide as graded plot plan Provide final grade, sod, splash blocks Provide covered deck pier inspections Seal exterior light fixtures No exterior items were inspected. To wet several inches of rain overnight.
Occupancy Inspection - Codes Residential Failed 4/23/2020 4/23/2020 04/23/2020
Misc
Corrective Action Required
04/23/2020
Provide as graded plot plan, pending approval Provide splash blocks at all downspout and sump pump discharge locations Provide covered deck pier inspections Seal exterior penetrations in siding
Occupancy Inspection - Codes Residential Failed 5/7/2020 5/7/2020 05/07/2020
Misc
Corrective Action Required
04/23/2020
- Pending as graded plot plan approval -
Plot Plan Inspection Passed 5/7/2020 05/07/2020
Occupancy Inspection - Codes Residential Full C of O 5/7/2020 05/07/2020
Misc
Resolved
05/07/2020
Documents & Images
Date Uploaded File Type Document Name
06/19/2019 Letter Codes Residential Plan Review
06/25/2019 Receipt Receipt for transaction: 2019-004104
06/25/2019 Letter Codes Building Permit
06/26/2019 Plot Plan DOC062519-06252019160431
07/22/2019 Letter INSPECTION SUMMARY
08/09/2019 Letter INSPECTION SUMMARY
08/09/2019 Letter INSPECTION SUMMARY
08/12/2019 Letter INSPECTION SUMMARY
10/25/2019 Letter INSPECTION SUMMARY
10/25/2019 Letter INSPECTION SUMMARY
10/25/2019 Letter INSPECTION SUMMARY
10/31/2019 Letter INSPECTION SUMMARY
10/31/2019 Letter INSPECTION SUMMARY
11/08/2019 Letter INSPECTION SUMMARY
11/11/2019 Letter INSPECTION SUMMARY
12/23/2019 Letter INSPECTION SUMMARY
01/02/2020 Letter INSPECTION SUMMARY
03/23/2020 Letter INSPECTION SUMMARY
03/27/2020 Letter Codes Temporary Certificate of Occupancy
04/22/2020 LOT 63 ASBUILT
04/23/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter Codes Final Certificate of Occupancy
05/07/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home