Summary
PRRES20190516
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
03/11/2019
03/19/2019
10/03/2019
Locations
Contacts
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
UNITED ELECTRIC COMPANY, Address:PO BOX 723, Phone:(816) 795-2744  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
chad@mcgraw-homes.com  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 03/13/2019 03/13/2019
Kim Brennan
06 Designate use of each room or space
Corrective Action Required
03/11/2019

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. no designation for the finished basement.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
03/11/2019

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) no egress shown in the master bedroom and bedroom #2.
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
03/11/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) no smoke detectors or carbon monoxide detectors shown on the main level or in the master bedroom and bedroom #2.
Plot Plan Review Approved 03/13/2019 03/13/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,186.94 $1,186.94 Paid 03/19/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/19/2019
8331507-Sewer Connection Fee $420.00 $420.00 Paid 03/19/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 03/19/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 03/19/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/20/2019 at 2:30 PM 03/20/2019
Sewer Service Inspection - R Passed 4/2/2019 (10:00) 4/2/2019 04/02/2019
Water Service Inspection - R Passed 4/2/2019 (10:00) 4/2/2019 04/02/2019
Water Service Inspection - R Passed 4/3/2019 4/3/2019 04/03/2019
Erosion Control Inspection Residential Failed 4/23/2019 04/23/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/23/2019
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 4/23/2019 4/23/2019 at 8:00 AM 04/23/2019
Piers/Caissons Inspection - Residential Failed 6/26/2019 (1:30) 6/26/2019 at 1:40 PM 06/26/2019
Misc
Corrective Action Required
06/26/2019
THE NW PIER NOT ALIGNED WITH THE POST
Piers/Caissons Inspection - Residential Passed 6/27/2019 6/27/2019 06/27/2019
Misc
Resolved
06/27/2019
THE NW PIER NOT ALIGNED WITH THE POST
Electrical Service Inspection Passed 6/27/2019 6/27/2019 06/27/2019
Gas Service Inspection - Residential Passed 6/27/2019 6/27/2019 06/27/2019
All Rough Inspection - Residential Failed 6/27/2019 6/27/2019 at 9:50 AM 06/27/2019
Misc
Corrective Action Required
06/27/2019
FRAMING: -Nail exterior wall sheathing per code outside front bedroom -Nail corner studs per code at rear dining -Front bedroom studs not continuous as required per code -Complete window framing in basement bedroom -Install beam underneath the foyer&hall bearing wall MECHANICAL: -Provide min 1” clearance from b vent to wood -Screw and tape duct joints above rear basement bedroom closet -Dryer duct disconnected. Support dryer duct -Provide combustion air openings per code ELECTRICAL: -Protect wiring inside front bedroom near door and outside at front entry wall **OK TO INSULATE
All Rough Inspection - Residential Passed 7/3/2019 7/3/2019 at 8:30 AM 07/03/2019
Misc
Resolved
07/03/2019
FRAMING: -Nail exterior wall sheathing per code outside front bedroom -Nail corner studs per code at rear dining -Front bedroom studs not continuous as required per code -Complete window framing in basement bedroom -Install beam underneath the foyer&hall bearing wall MECHANICAL: -Provide min 1” clearance from b vent to wood -Screw and tape duct joints above rear basement bedroom closet -Dryer duct disconnected. Support dryer duct -Provide combustion air openings per code ELECTRICAL: -Protect wiring inside front bedroom near door and outside at front entry wall **OK TO INSULATE
Driveway Inspection Passed 7/29/2019 7/29/2019 07/31/2019
Misc
Informational
07/29/2019
Driveway - forms and materials passed pre-inspection .
Misc
Informational
07/31/2019
Driveway - passed inspection .
Erosion Control Inspection Residential Passed 10/01/2019
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/01/2019
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 10/1/2019 10/1/2019 at 8:00 AM 10/01/2019
Corrective Action Required
10/01/2019
-The required receptacle within 3 ft of the sink in front bathroom shall be on the wall outside the cabinet, or on the cabinet wall no more than 12” below countertop -Install cranks for bedroom escape windows -Screw the basement walkout door embedded brace to studs -Lag deck ledger board through spacers -Provide way to clean out the furnace condensate drain -Locate and make accessible the ufer grounding connection
Occupancy Inspection - Codes Residential Full C of O 10/3/2019 10/3/2019 at 8:15 AM 10/03/2019
Documents & Images
Date Uploaded File Type Document Name
03/11/2019 Letter Codes Residential Plan Review
03/19/2019 Receipt Receipt for transaction: 2019-000941
03/19/2019 Letter Codes Building Permit
03/20/2019 Letter INSPECTION SUMMARY
03/22/2019 Plot Plan DOC032119-03212019134503
04/02/2019 Letter INSPECTION SUMMARY
04/02/2019 Letter INSPECTION SUMMARY
04/03/2019 Letter INSPECTION SUMMARY
04/23/2019 Letter INSPECTION SUMMARY
04/23/2019 Letter INSPECTION SUMMARY
06/26/2019 Letter INSPECTION SUMMARY
06/27/2019 Letter INSPECTION SUMMARY
06/27/2019 Letter INSPECTION SUMMARY
06/27/2019 Letter INSPECTION SUMMARY
07/03/2019 Letter INSPECTION SUMMARY
07/29/2019 Letter INSPECTION SUMMARY
07/31/2019 Letter INSPECTION SUMMARY
07/31/2019 Letter INSPECTION SUMMARY
10/01/2019 Letter INSPECTION SUMMARY
10/01/2019 Letter INSPECTION SUMMARY
10/03/2019 Letter Codes Final Certificate of Occupancy
10/03/2019 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home