Permit Application Status

PRRES20184043


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20184043
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
12/05/2018
12/17/2018
09/20/2019
Locations
Contacts
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
DAVE'S ELECTRIC, Address:1601 SW JEFFERSON ST, Phone:(816) 525-0409  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
WOODBROTHERSINC.GMAILCOM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 12/07/2018 12/12/2018
Kim Brennan
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
12/05/2018

Identify roof covering material (IRC Section R905)
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
12/05/2018

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
12/05/2018

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) does not specify uninterrupted height.
Plot Plan Review Approved 12/07/2018 12/11/2018
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,586.22 $1,586.22 Paid 12/17/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/17/2018
8331507-Sewer Connection Fee $570.00 $570.00 Paid 12/17/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 12/17/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 12/17/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/21/2018 12/21/2018 at 12:45 PM 12/21/2018
Underslab Plumbing Inspection - Residential Passed 2/5/2019 2/5/2019 at 9:30 AM 02/05/2019
Sewer Service Inspection - R Passed 2/28/2019 at 1:30 PM 02/28/2019
Water Service Inspection - R Passed 3/1/2019 (11:30) 3/1/2019 at 1:15 PM 03/01/2019
Piers/Caissons Inspection - Residential Passed 3/25/2019 3/25/2019 at 1:30 PM 03/25/2019
All Rough Inspection - Residential Failed 5/7/2019 5/7/2019 at 10:00 AM 05/07/2019
Misc
Corrective Action Required
05/07/2019
FRAMING: -In garage, frame out for kitchen hood duct and plumbing and fb as required -Fb floor penetrations by low voltage wiring -Fb space at 2nd fl hallway bathroom tub -Have engineer address lack of beam underneath lvl point loads at front bedroom closet/bed walls -Misplaced I beam support column in basement under half bath -Install joist hangers under fireplace area -Solid block under pantry lvl point load ELECTRICAL: -Should move receptacle boxes at kitchen countertop out a little bit so the boxes are not recessed behind the backsplash beyond allowance -Protect wiring at kitchen wall top plate near pex water line -Complete electrical in master bedroom -Securely fasten wiring home runs per code in master bedroom wall **OK TO INSULATE
Electrical Service Inspection Passed 5/7/2019 5/7/2019 05/07/2019
Gas Service Inspection - Residential Passed 5/7/2019 5/7/2019 05/07/2019
All Rough Inspection - Residential Passed 5/13/2019 5/13/2019 at 9:50 AM 05/13/2019
Misc
Resolved
05/13/2019
FRAMING: -In garage, frame out for kitchen hood duct and plumbing and fb as required -Fb floor penetrations by low voltage wiring -Fb space at 2nd fl hallway bathroom tub -Have engineer address lack of beam underneath lvl point loads at front bedroom closet/bed walls -Misplaced I beam support column in basement under half bath -Install joist hangers under fireplace area -Solid block under pantry lvl point load ELECTRICAL: -Should move receptacle boxes at kitchen countertop out a little bit so the boxes are not recessed behind the backsplash beyond allowance -Protect wiring at kitchen wall top plate near pex water line -Complete electrical in master bedroom -Securely fasten wiring home runs per code in master bedroom wall **OK TO INSULATE
Driveway Inspection Passed 12/27/2018 05/14/2019
Misc
Informational
05/14/2019
Driveway passed inspection.
Driveway Inspection Partial 7/10/2019 7/10/2019 07/15/2019
Misc
Informational
07/15/2019
Driveway - forms and materials passed pre - inspection .
Occupancy Inspection - Codes Residential Failed 8/26/2019 8/26/2019 at 9:15 AM 08/26/2019
Misc
Corrective Action Required
08/26/2019
-From all-rough: misplaced I beam support column in basement under half bath -Final grade, sod, roof drainage, and splash blocks -Seal above meter, AC disconnects -Water meter must be at final grade level. Distance from meter top to lid must be 14”-18” -Make sure the sewer tracer box and wire at grade level -Tamper proof caps at AC valves -Shall install listed transition risers at underground pex gas line transitions to above ground -Install stair at slide door -Install AFCI breaker for middle bed -Install breaker lock for out-of-sight water heater -Provide mean to clean out furnace condensate drain. FYI: it’s leaking bad -Remove all foundation wall ties -Anchor all steel columns to floor
Occupancy Inspection - Codes Residential Temporary C of O 8/28/2019 8/28/2019 at 1:15 PM 08/28/2019
Misc
Corrective Action Required
08/26/2019
-Sod,, and splash blocks -Bond gas piping -Water meter must be at final grade level. Distance from meter top to lid must be 14”-18” -Make sure the sewer tracer box and wire at grade level
Occupancy Inspection - Codes Residential Full C of O 9/20/2019 at 8:55 AM 09/20/2019
Misc
Resolved
09/20/2019
-Sod,, and splash blocks -Bond gas piping -Water meter must be at final grade level. Distance from meter top to lid must be 14”-18” -Make sure the sewer tracer box and wire at grade level
Documents & Images
Date Uploaded File Type Document Name
12/05/2018 Letter Codes Residential Plan Review
12/17/2018 Receipt Receipt for transaction: 2018-007588
12/17/2018 Letter Codes Building Permit
12/18/2018 Plot Plan DOC121818-12182018090024
02/05/2019 Letter INSPECTION SUMMARY
02/28/2019 Letter INSPECTION SUMMARY
03/01/2019 Letter INSPECTION SUMMARY
03/25/2019 Letter INSPECTION SUMMARY
05/07/2019 Letter INSPECTION SUMMARY
05/07/2019 Letter INSPECTION SUMMARY
05/07/2019 Letter INSPECTION SUMMARY
05/13/2019 Letter INSPECTION SUMMARY
05/14/2019 Letter INSPECTION SUMMARY
07/15/2019 Letter INSPECTION SUMMARY
08/26/2019 Letter INSPECTION SUMMARY
08/28/2019 Letter Codes Temporary Certificate of Occupancy
09/20/2019 Letter Codes Final Certificate of Occupancy
09/20/2019 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home