Permit Application Status

PRRES20183816


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20183816
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE UNFINISHED BASEMENT COVERED DECK
11/06/2018
11/15/2018
09/22/2021
Locations
Contacts
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
EVEN TEMP LLC, Address:748 N 100 RD, Phone:(785) 248-8756  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JP@LANDROCKKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 11/08/2018 11/15/2018
Development Center
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
11/06/2018

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) Application shows unfinished basement, plans show finished basement.
06 Designate use of each room or space
Corrective Action Required
11/06/2018

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. plans shows finished space in basement, application shows unfinished basement.
19 Footings, column pads, piers and grade beams - dimensions
Corrective Action Required
11/06/2018

Footings, column pads, piers and grade beams - dimensions. (IRC Section R403) no footing details found for foundation walls.
20 Footings, column pads, piers and grade beams - reinforcement
Corrective Action Required
11/06/2018

Footings, column pads, piers and grade beams - reinforcement size and spacing. no footing details found for foundation walls.
Plot Plan Review Approved 11/08/2018 11/09/2018
Steve Conrick
Sidewalks
Corrective Action Required
11/07/2018

Sidewalks with dimensions must be provided on the plot plan. ***Missing sidewalk shown on plat***
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,306.62 $1,306.62 Paid 11/15/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/15/2018
8331507-Sewer Connection Fee $450.00 $450.00 Paid 11/15/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 11/15/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 11/15/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/13/2018 (11:30) 12/13/2018 at 11:30 AM 12/13/2018
Underslab Plumbing Inspection - Residential Passed 1/11/2019 1/11/2019 at 9:00 AM 01/11/2019
Sewer Service Inspection - R Passed 1/22/2019 (8:30) 1/22/2019 at 9:15 AM 01/22/2019
Water Service Inspection - R Passed 1/24/2019 1/24/2019 at 3:46 PM 01/24/2019
All Rough Inspection - Residential Failed 4/4/2019 4/4/2019 at 2:25 PM 04/04/2019
Misc
Corrective Action Required
04/04/2019
Protect plumbing top and bottom plates at southeast corner of garage. Add stud shoe where stud is over bored. Fireplace is not mounted securely. Gas line is not connected at fireplace. No water line at water closet master bath. Install stud shoe at master bath shower. Add stud shoe at dryer drain. Add support at trey ceiling in dining area. O psi in gas line. Trim out windows on back bottom of house.
Electrical Service Inspection Passed 4/4/2019 4/4/2019 04/04/2019
Gas Service Inspection - Residential Failed 4/4/2019 4/4/2019 04/04/2019
Misc
Corrective Action Required
04/04/2019
0 psi in gas line. gas line is not connected to fire place
All Rough Inspection - Residential Failed 4/12/2019 4/12/2019 04/12/2019
Misc
Resolved
04/12/2019
Protect plumbing top and bottom plates at southeast corner of garage. Add stud shoe where stud is over bored. Fireplace is not mounted securely. Gas line is not connected at fireplace. No water line at water closet master bath. Install stud shoe at master bath shower. Add stud shoe at dryer drain. Add support at trey ceiling in dining area. O psi in gas line. Trim out windows on back bottom of house.
Misc
Corrective Action Required
04/12/2019
Fireplace is not mounted securely. fire stop gas line penetration at fire place. install missing doors in basement . OK TO INSULATE
Gas Piping Inspection - Residential Passed 4/12/2019 04/12/2019
Gas Service Inspection - Residential Passed 4/12/2019 04/12/2019
Misc
Corrective Action Required
04/04/2019
0 psi in gas line. gas line is not connected to fire place
Driveway Inspection Partial 6/6/2019 (P.M.) 6/6/2019 06/06/2019
Misc
Informational
06/06/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Failed 6/11/2019 07/02/2019
Misc
Informational
06/06/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Corrective Action Required
07/02/2019
POST POUR INSPECTION The driveway approach has a cross slope greater than 2.0 percent. Corrective action is required. Photos are attached.
Sidewalk Inspection Partial 7/23/2019 7/23/2019 07/23/2019
Misc
Informational
07/23/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Partial 7/23/2019 7/23/2019 07/23/2019
Misc
Informational
07/02/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Corrective Action Required
07/02/2019
POST POUR INSPECTION The driveway approach has a cross slope greater than 2.0 percent. Corrective action is required. Photos are attached.
Misc
Informational
07/23/2019
PRE POUR INSPECTION The drive approach that was out of ADA compliance was torn out and is now formed for replacement. The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 7/30/2019 08/05/2019
Misc
Informational
07/23/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 7/30/2019 08/05/2019
Misc
Corrective Action Required
07/23/2019
POST POUR INSPECTION The driveway approach has a cross slope greater than 2.0 percent. Corrective action is required. Photos are attached.
Misc
Informational
07/23/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Misc
Informational
07/23/2019
PRE POUR INSPECTION The drive approach that was out of ADA compliance was torn out and is now formed for replacement. The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 8/22/2019 8/22/2019 08/22/2019
Misc
Corrective Action Required
08/22/2019
**Support water heater vent ** Need handrail to basement ** Main level 1/2 bath light is not installed **Upstairs bedroom 1 egress window needs hand crank **Need self closer on garage door **Post address **Final ground stabilization **Porch is missing a joist hanger on the outside corner
Occupancy Inspection - Codes Residential Temporary C of O 8/23/2019 08/23/2019
Misc
Resolved
08/23/2019
**Support water heater vent ** Need handrail to basement ** Main level 1/2 bath light is not installed **Upstairs bedroom 1 egress window needs hand crank **Need self closer on garage door **Post address **Final ground stabilization **Porch is missing a joist hanger on the outside corner
Occupancy Inspection - Codes Residential Full C of O 09/22/2021
Documents & Images
Date Uploaded File Type Document Name
11/07/2018 Letter Codes Residential Plan Review
11/07/2018 Letter Codes Residential Plan Review
11/15/2018 Receipt Receipt for transaction: 2018-007235
11/15/2018 Letter Codes Building Permit
11/15/2018 Plot Plan DOC111518-004
12/13/2018 Letter INSPECTION SUMMARY
01/11/2019 Letter INSPECTION SUMMARY
01/22/2019 Letter INSPECTION SUMMARY
01/23/2019 Engineer Report/Study 4513 SW Nautilius Pl_Lot 14 Creekside at Raintree Lake Final_2019.01.15_GBSlab_LSMO_Pat Cochran Concrete
01/24/2019 Letter INSPECTION SUMMARY
03/28/2019 Engineer Report/Study 4513 SW Nautilus Pl_Lot 14 Creekside at Raintree Final_2019.03.28_SuspStoop_LSMO_Pat Cochran
04/04/2019 Letter INSPECTION SUMMARY
04/04/2019 Letter INSPECTION SUMMARY
04/04/2019 Letter INSPECTION SUMMARY
04/12/2019 Letter INSPECTION SUMMARY
04/12/2019 Letter INSPECTION SUMMARY
04/12/2019 Letter INSPECTION SUMMARY
06/06/2019 Letter INSPECTION SUMMARY
07/02/2019 Letter INSPECTION SUMMARY
07/02/2019 image
07/23/2019 Letter INSPECTION SUMMARY
07/23/2019 Letter INSPECTION SUMMARY
07/23/2019 Letter INSPECTION SUMMARY
08/05/2019 Letter INSPECTION SUMMARY
08/05/2019 Letter INSPECTION SUMMARY
08/22/2019 Letter INSPECTION SUMMARY
08/22/2019 Letter INSPECTION SUMMARY
08/23/2019 Letter Codes Temporary Certificate of Occupancy
09/22/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.