Permit Application Status

PRRES20183802


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20183802
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT SUSPENDED SLAB COVERED DECK RETAINING WALL
11/06/2018
01/28/2019
09/22/2021
Locations
Contacts
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
EVEN TEMP LLC, Address:748 N 100 RD, Phone:(785) 248-8756  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
JP@LANDROCKKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 11/08/2018 11/15/2018
Brandon Kalwei
10 Combustion air
Corrective Action Required
11/06/2018

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
19 Footings, column pads, piers and grade beams - dimensions
Corrective Action Required
11/06/2018

Footings, column pads, piers and grade beams - dimensions. (IRC Section R403) could not find details for footings
20 Footings, column pads, piers and grade beams - reinforcement
Corrective Action Required
11/06/2018

Footings, column pads, piers and grade beams - reinforcement size and spacing. could not find details for footings
Plot Plan Review Approved 11/08/2018 11/09/2018
Steve Conrick
Right-of-way
Corrective Action Required
11/07/2018

The right-of-way with dimensions must be provided on the plot plan.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,378.72 $1,378.72 Paid 01/28/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/28/2019
8331507-Sewer Connection Fee $660.00 $660.00 Paid 01/28/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 01/28/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 01/28/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 12/19/2019
9110078-Valuation Fee New Single Family $17.50 $17.50 Paid 12/19/2019
$1,396.22
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/4/2019 (8:45) 2/4/2019 at 9:00 AM 02/04/2019
Foundation Inspection - Residential Passed 2/25/2019 (1:00) 2/25/2019 at 1:45 PM 02/25/2019
Misc
Informational
02/25/2019
EXTENDED BASEMENT WALL FROM 9' TO 10' OK TO POUR
Erosion Control Inspection Residential Failed 3/12/2019 at 9:00 AM 03/12/2019
Misc
Corrective Action Required
03/12/2019
NO EROSION CONTROL, NO INSPECTIONS WILL BE PERFORMED
Underslab Plumbing Inspection - Residential Failed 3/12/2019 3/12/2019 at 9:06 AM 03/12/2019
Misc
Corrective Action Required
03/12/2019
WATER COVERING PIPE, NEEDS TO VISIBILE FOR INSPECTION. MIDDLE SHOWER NEEDS TO BE VENTED
Underslab Plumbing Inspection - Residential Failed 3/14/2019 3/14/2019 03/14/2019
Misc
Corrective Action Required
03/12/2019
STANDING WATER IN BASEMENT, PIPING NEEDS TO BE VISIBLE FOR INSPECTION. MIDDLE SHOWER NEEDS TO BE VENTED
Underslab Plumbing Inspection - Residential Failed 3/18/2019 3/18/2019 at 8:16 AM 03/18/2019
Misc
Resolved
03/18/2019
STANDING WATER IN BASEMENT, PIPING NEEDS TO BE VISIBLE FOR INSPECTION. MIDDLE SHOWER NEEDS TO BE VENTED
Misc
Corrective Action Required
03/18/2019
NO VISIBLE ADDRESS.
Underslab Plumbing Inspection - Residential Passed 3/20/2019 3/20/2019 at 7:30 AM 03/20/2019
Misc
Resolved
03/20/2019
NO VISIBLE ADDRESS.
Sewer Service Inspection - R Passed 5/1/2019 at 12:40 PM 05/01/2019
Water Service Inspection - R Passed 5/2/2019 5/2/2019 at 11:00 AM 05/02/2019
All Rough Inspection - Residential Failed 8/6/2019 8/6/2019 at 10:45 AM 08/06/2019
Misc
Corrective Action Required
08/06/2019
Strap top plate at gas line penetration in laundry room. Fire block above fireplace in great room. Fire block above oven location. Protect plumbing at back side of master bath vanity. Protect plumbing left side of makeup counter top and bottom. Complete plumbing , drain , water supply, protect plumbing top bottom middle of master bath shower. Install stud shoes at middle bath plumbing in basement. Install bath fan in east bath in basement. Set ground screw at main panel. Repair hole in siding and ledger board missed bore under deck. plumber was still working on gas line at time of inspection. no gauge on gas line.
Gas Service Inspection - Residential Failed 8/6/2019 8/6/2019 08/06/2019
Misc
Corrective Action Required
08/06/2019
gas line not complete no gauge on gas line.
Electrical Service Inspection Failed 8/6/2019 8/6/2019 at 11:45 AM 08/06/2019
Misc
Corrective Action Required
08/06/2019
set panel ground screw at main panel.
All Rough Inspection - Residential Passed 8/7/2019 8/7/2019 08/07/2019
Misc
Resolved
08/07/2019
Gas Service Inspection - Residential Passed 8/7/2019 8/7/2019 08/07/2019
Misc
Resolved
08/07/2019
Electrical Service Inspection Passed 8/7/2019 8/7/2019 08/07/2019
Misc
Resolved
08/07/2019
Driveway Inspection Partial 9/13/2019 09/13/2019
Misc
Informational
09/13/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 9/18/2019 09/25/2019
Misc
Informational
09/13/2019
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 12/13/2019 12/13/2019 12/13/2019
Misc
Corrective Action Required
12/13/2019
Not ready for occupancy inspection, contractors still working and too many initial issues. Call in when ready
Occupancy Inspection - Codes Residential Failed 12/17/2019 12/17/2019 12/20/2019
Misc
Corrective Action Required
12/13/2019
- seal exterior light fixtures, penetrations, etc - garage door needs to be self closing/ latching - put cover plate on electrical box outside of master bedroom - security screws needed for master bedroom exterior door - complete lighting in master bathroom - complete lighting in master closet - install cover for clean out on west side of basement - security screws needed for all exterior doors - fire protect I joist in unfinished area of basement - properly vent furnace in unfinished basement area - anchor beam posts in unfinished basement area - tighten beam bolts in unfinished basement area, west side - stair stringers in storage area underneath stairs leading to basement need to be fire protected - outlet cover needed above basement bar sink - nail double joist hanger and single joist hanger on deck connection, north side of deck - protect retaining wall area from up above, needs to be fenced around or other - obtain building permit for retaining wall on west side of property
Occupancy Inspection - Codes Residential Temporary C of O 12/20/2019 12/20/2019
Misc
Corrective Action Required
12/20/2019
- seal exterior light fixtures, penetrations, etc - garage door needs to be self closing/ latching - put cover plate on electrical box outside of master bedroom - security screws needed for master bedroom exterior door - complete lighting in master bathroom - complete lighting in master closet - install cover for clean out on west side of basement - security screws needed for all exterior doors - fire protect I joist in unfinished area of basement - properly vent furnace in unfinished basement area - anchor beam posts in unfinished basement area - tighten beam bolts in unfinished basement area, west side - stair stringers in storage area underneath stairs leading to basement need to be fire protected - outlet cover needed above basement bar sink - nail double joist hanger and single joist hanger on deck connection, north side of deck - protect retaining wall area from up above, needs to be fenced around or other - obtain building permit for retaining wall on west side of property
Documents & Images
Date Uploaded File Type Document Name
11/07/2018 Letter Codes Residential Plan Review
11/07/2018 Letter Codes Residential Plan Review
01/28/2019 Receipt Receipt for transaction: 2019-000277
01/28/2019 Letter Codes Building Permit
01/29/2019 Plot Plan DOC012919-01292019075305
02/04/2019 Letter INSPECTION SUMMARY
02/25/2019 Letter INSPECTION SUMMARY
03/12/2019 Letter INSPECTION SUMMARY
03/12/2019 Letter INSPECTION SUMMARY
03/14/2019 Letter INSPECTION SUMMARY
03/18/2019 Letter INSPECTION SUMMARY
03/20/2019 Letter INSPECTION SUMMARY
04/19/2019 Engineer Report/Study Final_2019.04.11_SuspGSlab_Pat Cochran Concrete
05/01/2019 Letter INSPECTION SUMMARY
05/02/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter INSPECTION SUMMARY
08/06/2019 Letter INSPECTION SUMMARY
08/07/2019 Letter INSPECTION SUMMARY
08/07/2019 Letter INSPECTION SUMMARY
08/07/2019 Letter INSPECTION SUMMARY
09/13/2019 Letter INSPECTION SUMMARY
09/25/2019 Letter INSPECTION SUMMARY
12/13/2019 Letter INSPECTION SUMMARY
12/17/2019 Letter INSPECTION SUMMARY
12/19/2019 Receipt Receipt for transaction: 2019-007779
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home