Permit Application Status

PRRES20182738


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20182738
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
08/20/2018
09/20/2018
03/03/2019
09/11/2020
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
MCFARLAND CUSTOM BUILDERS, Address:P O BOX 25285, Phone:(816) 215-1660  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
JOE KILOWATT INC, Address:6506 ROYAL, Phone:(816) 792-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/06/2018 09/14/2018
Kim Brennan
Plot Plan Review Approved 09/06/2018 09/04/2018
Kim Brennan
Plot Plan Review Approved 08/22/2018 08/22/2018
Steve Conrick
Residential Plan Review Rejected 08/22/2018 08/20/2018
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,250.24 $1,250.24 Paid 09/20/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/20/2018
8331507-Sewer Connection Fee $570.00 $570.00 Paid 09/20/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 09/20/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 09/20/2018
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 08/16/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/17/2018 10/17/2018 at 3:30 PM 10/17/2018
Sewer Service Inspection - R Passed 11/29/2018 (2:30) 11/29/2018 11/29/2018
Water Service Inspection - R Passed 11/30/2018 11/30/2018 11/30/2018
Underslab Plumbing Inspection - Residential Failed 12/4/2018 12/4/2018 12/04/2018
Misc
Corrective Action Required
12/04/2018
City requires a 4” cleanout for building sewer.
Underslab Plumbing Inspection - Residential Passed 12/17/2018 12/17/2018 12/17/2018
Misc
Resolved
12/17/2018
City requires a 4” cleanout for building sewer.
All Rough Inspection - Residential Not Ready 5/30/2019 5/30/2019 05/30/2019
Misc
Corrective Action Required
05/30/2019
INSTALL EROSION CONTROL AS REQURIED ALL INSPECTIONS DENIED UNTILL EROSION CONTROL IS IN PLACE
All Rough Inspection - Residential Not Ready 6/4/2019 6/4/2019 06/04/2019
Misc
Corrective Action Required
05/30/2019
INSTALL EROSION CONTROL AS REQURIED ALL INSPECTIONS DENIED UNTILL EROSION CONTROL IS IN PLACE. locked no nockbox code not ready
All Rough Inspection - Residential Not Ready 6/5/2019 6/5/2019 06/05/2019
Misc
Corrective Action Required
06/04/2019
INSTALL EROSION CONTROL AS REQURIED ALL INSPECTIONS DENIED UNTILL EROSION CONTROL IS IN PLACE. locked no nockbox code not ready
Misc
Corrective Action Required
06/05/2019
No city approved plans on site. Provide City of Lee's Summit stamped set with permit number and address on site at time of inspection. install silt fence at rear of lot and south down hill side. -contain all trash and construction debris in front yard. install fire stopping and complete electrical in garage, front garage walls. see list from 2505 complete on this house before recalling for inspection. 3rd not ready inspection pay assessed fees .
All Rough Inspection - Residential Failed 6/20/2019 6/20/2019 06/20/2019
Misc
Resolved
06/20/2019
INSTALL EROSION CONTROL AS REQURIED ALL INSPECTIONS DENIED UNTILL EROSION CONTROL IS IN PLACE. locked no nockbox code not ready
Misc
Corrective Action Required
06/05/2019
**fire stop flue chase in garage vertical to horizontal. #Electrical in return air garage wll. #Install braced wall panels throughout, rear wall, hold downs , nail siding per plans. #Solid block all joist over beams, bearing walls, cantilevers.. # support flat ceiling joist 3' o.c. garage ceiling. #install 2 x6 walls per plans at stair walls. #Support flex heat duct in attic 6'o.c. #install wall receptacles with 6' of door and any wall 24" , see 2nd floor bedrooms. #install solid block at flue chase 2nd floor front side. do not cover
Gas Service Inspection - Residential Passed 6/20/2019 6/20/2019 06/20/2019
Electrical Service Inspection Passed 6/20/2019 6/20/2019 06/20/2019
All Rough Inspection - Residential Not Ready 8/5/2019 8/5/2019 08/05/2019
Misc
Corrective Action Required
06/20/2019
Items not addressed- over grown vegitation , No inspections until all weeds are mowed. **fire stop flue chase in garage vertical to horizontal. #Electrical in return air garage wall. NOT SEALED #Install braced wall panels throughout, rear wall, hold downs , nail siding per plans. # support flat ceiling joist 3' o.c. garage ceiling.INCOMPLETE #install 2 x6 walls per plans at stair walls.NOT ADDRESSED #Support flex heat duct in attic 6'o.c. #install wall receptacles with 6' of door and any wall 24" , see 2nd floor bedrooms. INCOMLETE #install solid block at flue chase 2nd floor front side. do not cover INCOMPLETE wood incontact with flue.
Piers/Caissons Inspection - Residential Passed 8/9/2019 8/9/2019 08/09/2019
All Rough Inspection - Residential Failed 8/12/2019 8/12/2019 08/12/2019
Misc
Corrective Action Required
08/05/2019
**fire stop flue chase in garage vertical to horizontal, fire blocking insulation loose, need solid blocking #install wall receptacles with 6' of door and any wall 24" , see 2nd floor bedrooms. INCOMLETE #install solid block at flue chase 2nd floor front side. do not cover INCOMPLETE wood incontact with flue. *ok to insulate
All Rough Inspection - Residential Failed 8/16/2019 8/16/2019 08/16/2019
Misc
Corrective Action Required
08/12/2019
**fire stop flue chase in garage vertical to horizontal, fire blocking insulation loose, need solid blocking #install solid block at flue chase 2nd floor front side. do not cover INCOMPLETE wood incontact with flue. *ok to insulate
All Rough Inspection - Residential Passed 8/21/2019 8/21/2019 08/21/2019
Misc
Resolved
08/21/2019
**fire stop flue chase in garage vertical to horizontal, fire blocking insulation loose, need solid blocking #install solid block at flue chase 2nd floor front side. do not cover INCOMPLETE wood incontact with flue. *ok to insulate
Driveway Inspection Partial 9/11/2019 9/11/2019 09/11/2019
Misc
Informational
09/11/2019
PREP OUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 9/18/2019 09/25/2019
Misc
Informational
09/11/2019
PREP OUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Plot Plan Inspection Passed 12/12/2019 12/12/2019
Occupancy Inspection - Codes Residential Temporary C of O 12/19/2019 12/19/2019 12/19/2019
Misc
Corrective Action Required
12/19/2019
Provide anti tip device range Provide cover for attic access garage Provide sod Water meter snow covered No plot plan inspection lot snow covered Provide tamper proof caps A/C condenser
Deck Final Inspection - Residential Passed 9/11/2020 09/11/2020
Occupancy Inspection - Codes Residential Full C of O 9/11/2020 09/11/2020
Misc
Resolved
09/11/2020
Documents & Images
Date Uploaded File Type Document Name
08/21/2018 Letter Codes Residential Plan Review
09/20/2018 Receipt Receipt for transaction: 2018-006480
09/20/2018 Letter Codes Building Permit
09/21/2018 Plot Plan DOC092018-09202018160722
10/17/2018 Letter Inspection Summary
11/29/2018 Letter INSPECTION SUMMARY
11/30/2018 Letter INSPECTION SUMMARY
11/30/2018 Letter Codes Residential Plan Review
12/17/2018 Letter INSPECTION SUMMARY
12/17/2018 Letter INSPECTION SUMMARY
05/30/2019 Letter INSPECTION SUMMARY
06/04/2019 Letter INSPECTION SUMMARY
06/05/2019 Letter INSPECTION SUMMARY
06/20/2019 Letter INSPECTION SUMMARY
08/05/2019 Letter INSPECTION SUMMARY
08/09/2019 Letter INSPECTION SUMMARY
08/12/2019 Letter INSPECTION SUMMARY
08/16/2019 Letter INSPECTION SUMMARY
08/16/2019 Receipt Receipt for transaction: 2019-005632
08/21/2019 Letter INSPECTION SUMMARY
09/11/2019 Letter INSPECTION SUMMARY
09/25/2019 Letter INSPECTION SUMMARY
12/10/2019 Plot Plan Eagle Creek 14th Plat Lot 687 FG 19.1209
12/12/2019 Letter INSPECTION SUMMARY
12/19/2019 Letter Codes Temporary Certificate of Occupancy
04/22/2020 Eagle Creek 14th Plat Lot 687 FG 19.1209
09/11/2020 Letter Codes Final Certificate of Occupancy
09/11/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home