Permit Application Status

PRRES20181886


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20181886
Building Permit - Residential
Certificate of Occupancy
SBISA HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK ROOFING MATERIAL - FIBERGLASS SHINGLES
06/19/2018
07/03/2018
07/10/2019
Locations
Contacts
SBISA HOMES INC, Address:29710 E WINDMILL RIDGE LN  
SBISA HOMES INC, Address:29710 WINDMILL RIDGE LN, Phone:(816) 697-3604  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/21/2018 07/03/2018
Brandon Kalwei
Spot elevations
Corrective Action Required
06/21/2018

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. *** Provide contours and spot elevations throughout the lot to give better understanding of proposed finished grading***
Basement egress
Corrective Action Required
06/21/2018

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. ***Show location of walkout and provide lowest adjacent grade***
City infrustructure
Corrective Action Required
06/21/2018

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. ***Provide flow line of inlet***
Residential Plan Review Approved 06/21/2018 07/03/2018
Brandon Kalwei
Licensed Contractors Approved 06/19/2018 06/19/2018
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,322.46 $1,322.46 Paid 07/03/2018
Right of Way Permit Fee $75.00 $75.00 Paid 07/03/2018
8331507-Sewer Connection Fee $600.00 $600.00 Paid 07/03/2018
Water Tap Fee $3,343.00 $3,343.00 Paid 07/03/2018
Water Meter Fee $431.83 $431.83 Paid 07/03/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 7/23/2018 07/23/2018
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/23/2018
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. **SHALL PROVIDE 3/4" GRAVEL AT LOT ENTRANCE; REPAIR EROSION CONTROL AT FRONT SW CORNER
Footing Inspection - Residential Passed 7/23/2018 7/23/2018 at 1:15 PM 07/23/2018
Erosion Control Inspection Residential Failed 8/9/2018 08/09/2018
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/23/2018
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. **SHALL PROVIDE 3/4" GRAVEL AT LOT ENTRANCE; REPAIR EROSION CONTROL AT FRONT SW CORNER
Underslab Plumbing Inspection - Residential Passed 8/9/2018 8/9/2018 at 9:20 AM 08/09/2018
Underslab Plumbing Inspection - Residential Passed 8/10/2018 8/10/2018 at 9:05 AM 08/10/2018
Water Service Inspection - R Partial 8/20/2018 at 1:05 PM 08/20/2018
Sewer Service Inspection - R Passed 8/21/2018 (1:00) 8/21/2018 at 1:00 PM 08/21/2018
Water Service Inspection - R Passed 8/21/2018 (1:00) 8/21/2018 08/21/2018
Piers/Caissons Inspection - Residential Passed 8/28/2018 8/28/2018 at 9:15 AM 08/28/2018
Erosion Control Inspection Residential Failed 2/13/2019 02/13/2019
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/09/2018
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. **PROVIDE 3/4" GRAVEL AT LOT ENTRANCE; REPAIR EROSION CONTROL ALL AROUND
Gas Service Inspection - Residential Passed 2/13/2019 2/13/2019 02/13/2019
Electrical Service Inspection Failed 2/13/2019 2/13/2019 02/13/2019
Misc
Corrective Action Required
02/13/2019
-Provide listing for the lug that allows two grounding electrode conductors to connect at same lug
All Rough Inspection - Residential Failed 2/13/2019 2/13/2019 at 8:45 AM 02/13/2019
Misc
Corrective Action Required
02/13/2019
FRAMING: -Install collar ties near ridge above garage -Install joist hangers at garage b vent/duct chase -Fb garage duct chase from soffit and joist space -Fur out at garage wall return air for R13 insulation -Solidblock lapped joists above bearing wall between garage and dwelling -Install full bearing support for double joist beam inside and outside laundry room. -Look above for the triple roof beam above north bedroom, install full support at both ends of the beam down to floor -Install joist hangers for all connections to kitchen I beam. -Install full bearing support for all triple&double joist/lvl beams in kitchen and dining area. Get electrician involved and do not notch added studs -Solidblock all cantilevered joists at kitchen exterior wall -Support at top of lvl hip above smaller master closet -Fb space at master shower -Install hanger for ceiling beam above master bath -Support bottom of lvl hip at larger master closet corner -Support bearing wall at front bedroom/closet -Duct outside east bedroom wall -Bearing wall along north bathroom/bed/closet not aligned with beam below. You can block between joists at four ft interval -Exposed TJI joists must be protected per IRC501. Check on final -Support joist above furnace -Anchor sill plates in basement per code -Install hangers for lvl-lvl connections and joist-lvl connections at stair -Provide CS-WSP walls per plan MECHANICAL: -Complete kitchen hood ducting at east bedroom ELECTRICAL: -Cannot screw boxes to stud from inside, except within 1/4” of back side of boxes **DO NOT INSULATE
All Rough Inspection - Residential Failed 2/22/2019 2/22/2019 at 8:00 AM 02/22/2019
Misc
Corrective Action Required
02/13/2019
FRAMING: -Fb garage duct chase from soffit and joist space **Please cut out the wood near the b-vent. Need min 1" air gap around the b-vent. Use insulation to fb this space -Look above for the triple roof beam above north bedroom, install full support at both ends of the beam down to floor **Need full support for this beam all the way down to main floor. Point load is outside the laundry rm and near the b-vent chase. There is no support for the point load at the b-vent chase. -Support joist above furnace **use a simpson L bracket to support the joist to the rim band. -Install hangers for lvl-lvl connections and joist-lvl connections at stair **Why so many I joists not properly supported? -Provide CS-WSP walls per plan **Brace the walls per plan. **Exposed TJI joists must be protected per IRC501. Check on final **OK TO INSULATE
Electrical Service Inspection Passed 2/22/2019 02/22/2019
Misc
Resolved
02/22/2019
-Provide listing for the lug that allows two grounding electrode conductors to connect at same lug
All Rough Inspection - Residential Failed 2/26/2019 2/26/2019 at 9:20 AM 02/26/2019
Misc
Corrective Action Required
02/22/2019
-Install hangers for lvl-lvl connections and joist-lvl connections at stair **Check later per engneer report **Exposed TJI joists must be protected per IRC501. Check on final **OK TO ROCK
Occupancy Inspection - Codes Residential Failed 7/1/2019 6/28/2019 06/28/2019
Misc
Corrective Action Required
06/28/2019
-Occupied with personal items inside, remove before next inspection -no address posted -builder needed to be present if items are still present
Sidewalk Inspection Passed 6/7/2019 6/7/2019 06/28/2019
Informational
06/07/2019
Sidewalk- forms and material passed pre-inspection.
Misc
Informational
06/28/2019
Sidewalk passed final inspection .
Driveway Inspection Passed 6/6/2019 6/6/2019 06/28/2019
Informational
06/07/2019
Driveway-forms and materials passed pre-inspection.
Misc
Informational
06/28/2019
Driveway passed final inspection .
All Rough Inspection - Residential Passed 07/01/2019
Misc
Resolved
07/01/2019
-Install hangers for lvl-lvl connections and joist-lvl connections at stair **Check later per engneer report **Exposed TJI joists must be protected per IRC501. Check on final **OK TO ROCK
Erosion Control Inspection Residential Passed 07/01/2019
DCM2 ESC DEFICIENT INSTALLATION
Resolved
07/01/2019
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. **PROVIDE 3/4" GRAVEL AT LOT ENTRANCE; REPAIR EROSION CONTROL ALL AROUND
Occupancy Inspection - Codes Residential Failed 7/1/2019 7/1/2019 at 8:55 AM 07/01/2019
Misc
Corrective Action Required
06/28/2019
-Install lag screws for deck ledger boards. 2 at each end and every 16" -Clean out foundation drain tile to daylight -Install stair guardrail and handrail. Handrail and guardrail must be installed before the TCO can be issued -Install breaker lock for kitchen hood and cooktop, and oven -Garage door not self closing -Garage stair riser heights not compliant. Top riser height more than 7-3/4”, measured from door threshold to tread. All riser heights must be consistent with max difference of no more than 3/8” -Support receptacle yoke at right side of laundry sink -Install CO and smoke alarm immediately outside master bedroom. The one in the master bathroom/bedroom does not meet this requirement -Install bedroom escape window hardware -Protect exposed TJI joists -Install anti-backflow device at basement hose Bibb -Support basement receptacle yokes
Occupancy Inspection - Codes Residential Full C of O 7/10/2019 7/10/2019 at 11:15 AM 07/10/2019
Misc
Resolved
07/10/2019
-Install lag screws for deck ledger boards. 2 at each end and every 16" -Clean out foundation drain tile to daylight -Install stair guardrail and handrail. Handrail and guardrail must be installed before the TCO can be issued -Install breaker lock for kitchen hood and cooktop, and oven -Garage door not self closing -Garage stair riser heights not compliant. Top riser height more than 7-3/4”, measured from door threshold to tread. All riser heights must be consistent with max difference of no more than 3/8” -Support receptacle yoke at right side of laundry sink -Install CO and smoke alarm immediately outside master bedroom. The one in the master bathroom/bedroom does not meet this requirement -Install bedroom escape window hardware -Protect exposed TJI joists -Install anti-backflow device at basement hose Bibb -Support basement receptacle yokes
Documents & Images
Date Uploaded File Type Document Name
06/19/2018 Letter Codes Residential Plan Review
06/21/2018 Letter Codes Residential Plan Review
07/03/2018 Receipt Receipt for transaction: 2018-004613
07/03/2018 Letter Codes Building Permit
07/05/2018 Plot Plan DOC070518-07052018142444
07/23/2018 Letter Inspection Summary
08/09/2018 Letter Inspection Summary
08/10/2018 Letter Inspection Summary
08/20/2018 Letter Inspection Summary
08/21/2018 Letter Inspection Summary
08/28/2018 Letter Inspection Summary
02/15/2019 Engineer Report/Study DOC021519
02/22/2019 Letter INSPECTION SUMMARY
02/22/2019 Letter INSPECTION SUMMARY
02/26/2019 Letter INSPECTION SUMMARY
06/07/2019 Letter DE-Daily Inspection Summary
06/28/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter INSPECTION SUMMARY
07/01/2019 Letter INSPECTION SUMMARY
07/01/2019 Letter INSPECTION SUMMARY
07/01/2019 Letter INSPECTION SUMMARY
07/10/2019 Letter Codes Final Certificate of Occupancy
07/10/2019 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home