Summary
PRRES20181851
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - UNCOVERED DECK
06/15/2018
06/20/2018
02/19/2020
Locations
Contacts
CHOYCE LLC, Address:PO BOX 847  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/19/2018 06/19/2018
Steve Conrick
Residential Plan Review Approved 06/19/2018 06/15/2018
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,381.40 $1,381.40 Paid 06/20/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 06/20/2018
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 06/20/2018
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/20/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 06/20/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 06/20/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/28/2018 (9:00) 6/28/2018 06/28/2018
Underslab Plumbing Inspection - Residential Passed 7/19/2018 7/19/2018 at 11:30 AM 07/19/2018
Sewer Service Inspection - R Passed 7/23/2018 7/23/2018 at 2:20 PM 07/23/2018
Water Service Inspection - R Partial 7/24/2018 7/24/2018 at 10:30 AM 07/24/2018
Water Service Inspection - R Passed 7/24/2018 at 1:00 PM 07/24/2018
Suspended Slab Inspection Passed 8/15/2018 8/15/2018 at 2:00 PM 08/15/2018
Piers/Caissons Inspection - Residential Not Ready 08/16/2018
Misc
Corrective Action Required
08/16/2018
contractor called and canceled
Gas Piping Inspection - Residential Passed 9/27/2018 9/27/2018 at 9:20 AM 09/27/2018
Electrical Service Inspection Passed 10/10/2018 10/10/2018 at 12:31 PM 10/10/2018
Gas Service Inspection - Residential Passed 10/10/2018 10/10/2018 at 12:42 PM 10/10/2018
All Rough Inspection - Residential Failed 10/10/2018 10/10/2018 at 12:52 PM 10/10/2018
Misc
Corrective Action Required
10/10/2018
• nail off garage portal sheathing per code 3” oc • Add anchor bolt at west side of portal anchor has missed plate • Add anchors within 12 “ of splices in bottom plate on west side of garage • Add anchors at south side bottom plate in garage • Add anchor at northeast portal • Complete fir out in garage and firestop • Add joist hangers where joist is headered off in flex rm • Add joist hangers in kitchen at joists that are headered off • Fire block at back side of fir out at range • Strap top plate at north wall right and left of windows in dining room • Cut double lvl in master bedroom provide engineers report • Complete snow blocking in master bedroom on south wall • Anchor all steel support posts in basement • Security blocking at basement egress door • Anchor sill plate at south side of stairs within 12” of splice • Anchor sill plate at south wall right of triple windows • Tighten nut at plate anchor at north west corner of basement • Is all joist hangers to header at cut joist in basement and repair hole in floor sheathing.
All Rough Inspection - Residential Partial 10/23/2018 10/23/2018 at 9:30 AM 10/23/2018
Misc
Resolved
10/23/2018
• nail off garage portal sheathing per code 3” oc • Add anchor bolt at west side of portal anchor has missed plate • Add anchors within 12 “ of splices in bottom plate on west side of garage • Add anchors at south side bottom plate in garage • Add anchor at northeast portal • Complete fir out in garage and firestop • Add joist hangers where joist is headered off in flex rm • Add joist hangers in kitchen at joists that are headered off • Fire block at back side of fir out at range • Strap top plate at north wall right and left of windows in dining room • Cut double lvl in master bedroom provide engineers report • Complete snow blocking in master bedroom on south wall • Anchor all steel support posts in basement • Security blocking at basement egress door • Anchor sill plate at south side of stairs within 12” of splice • Anchor sill plate at south wall right of triple windows • Tighten nut at plate anchor at north west corner of basement • Is all joist hangers to header at cut joist in basement and repair hole in floor sheathing.
Misc
Resolved
11/02/2018
ANCHOR 1 STEEL SUPPORT POST IN BASEMENT *PROVIDE ENGINEERS REPORT ON CUT LVL IN MASTER BEDROOM. * OK TO INSULATE *
All Rough Inspection - Residential Passed 11/2/2018 11/2/2018 at 10:51 AM 11/02/2018
Misc
Corrective Action Required
10/23/2018
ANCHOR 1 STEEL SUPPORT POST IN BASEMENT *PROVIDE ENGINEERS REPORT ON CUT LVL IN MASTER BEDROOM. * OK TO INSULATE *
Driveway Inspection Partial 12/10/2018 (P.M.) 12/10/2018 12/10/2018
Misc
Informational
12/10/2018
Forms were set to achieve ADA compliance. Aggregate was compacted.
Sidewalk Inspection Partial 12/10/2018
Misc
Informational
12/10/2018
Forms were set to achieve ADA compliance, gravel was compacted.
Sidewalk Inspection Passed 12/14/2018 12/18/2018 12/18/2018
Misc
Informational
12/10/2018
Forms were set to achieve ADA compliance, gravel was compacted.
Driveway Inspection Passed 12/14/2018 12/18/2018 12/18/2018
Misc
Informational
12/10/2018
Forms were set to achieve ADA compliance. Aggregate was compacted.
Occupancy Inspection - Codes Residential Temporary C of O 2/26/2019 2/26/2019 at 8:31 AM 02/26/2019
Misc
Corrective Action Required
02/26/2019
1. GUTTERS 2.PAINT EXTERIOR 3. FINAL GRADE AND REMOVE CONSTRUCTION DEBRIS. 4. SOD 5. INSTALL STAIRS AT DECK. 6. SPLASH BLOCKS.
Plot Plan Inspection Failed 4/26/2019 at 8:00 AM 04/26/2019
Misc
Corrective Action Required
04/26/2019
1.THERE IS ASMALL SINK HOLE LOCATED IN THE FRONT YARD AT SOUTHEAST SIDE OF YARD CLOSE TO THE WATER METER. 2.THERE IS A LARGE SINK HOLE ON NORTHWEST SIDE OF FRONT YARD LEFT OF DRIVEWAY. 3. CONFIRM 6" OF FALL IN FIRST 10' IN BACK OF HOUSE
Occupancy Inspection - Codes Residential Temporary C of O 4/26/2019 at 7:30 AM 04/26/2019
Misc
Resolved
04/26/2019
1. GUTTERS 2.PAINT EXTERIOR 3. FINAL GRADE AND REMOVE CONSTRUCTION DEBRIS. 4. SOD 5. INSTALL STAIRS AT DECK. 6. SPLASH BLOCKS.
Misc
Corrective Action Required
04/26/2019
1.THERE IS ASMALL SINK HOLE LOCATED IN THE FRONT YARD AT SOUTHEAST SIDE OF YARD CLOSE TO THE WATER METER. 2.THERE IS A LARGE SINK HOLE ON NORTHWEST SIDE OF FRONT YARD LEFT OF DRIVEWAY. 3. CONFIRM 6" OF FALL IN FIRST 10' IN BACK OF HOUSE. PROVIDE BACKFLOW CERTIFICATION FOR IRRIGATION.
Plot Plan Inspection Passed 02/19/2020
Misc
Resolved
02/19/2020
Occupancy Inspection - Codes Residential Full C of O 2/19/2020 2/19/2020 02/19/2020
Misc
Resolved
02/19/2020
Documents & Images
Date Uploaded File Type Document Name
06/20/2018 Receipt Receipt for transaction: 2018-004042
06/20/2018 Letter Codes Building Permit
06/21/2018 Plot Plan DOC062118-06212018113626
06/28/2018 Letter Inspection Summary
07/19/2018 Letter Inspection Summary
07/23/2018 Letter Inspection Summary
07/24/2018 Letter Inspection Summary
07/24/2018 Letter Inspection Summary
08/15/2018 Letter Inspection Summary
08/16/2018 Letter Inspection Summary
09/27/2018 Letter Inspection Summary
10/10/2018 Letter Inspection Summary
10/23/2018 Letter Inspection Summary
10/30/2018 Engineer Report/Study 1531 SW Blackstone Pl Final_2018.10.24_Struct_LSMO_Kevin Higdon Construction
11/02/2018 Letter Inspection Summary
12/10/2018 Letter INSPECTION SUMMARY
12/10/2018 Letter INSPECTION SUMMARY
12/18/2018 Letter DE-Daily Inspection Summary
02/26/2019 Letter Codes Temporary Certificate of Occupancy
04/26/2019 Letter INSPECTION SUMMARY
04/26/2019 Letter Codes Temporary Certificate of Occupancy
02/19/2020 Letter INSPECTION SUMMARY
02/19/2020 Letter Field Certificate of Occupancy
02/19/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home