Summary
PRRES20181846
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
06/15/2018
06/22/2018
04/17/2020
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 346  
BRIAN CHANEY CONSTRUCTION, LLC, Address:PO BOX 646, Phone:(816) 838-0821  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
O'CONNELL ELECTRIC LLC, Address:11017 S ALLEY JACKSON RD, Phone:(816) 547-4706  
LRW PLUMBING LLC, Address:20631 W 319TH ST, Phone:(913) 568-7737  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/19/2018 06/22/2018
Steve Conrick
Drainage swales
Corrective Action Required
06/19/2018

Drainage swales (where required); show spot elevations within the swale as required to conform to the approved master drainage plan (if applicable), must be provide ***The area along the West side of the house is very flat. Reconfigure it to show atleast 2% from the rear of the house to the property corner.***
Residential Plan Review Approved 06/19/2018 06/21/2018
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
06/15/2018

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) no egress shown for bedrooms on the main floor
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
06/15/2018

Identify roof covering material (IRC Section R905)
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $927.39 $927.39 Paid 06/22/2018
Right of Way Permit Fee $75.00 $75.00 Paid 06/22/2018
8331507-Sewer Connection Fee $390.00 $390.00 Paid 06/22/2018
Water Tap Fee $3,343.00 $3,343.00 Paid 06/22/2018
Water Meter Fee $431.83 $431.83 Paid 06/22/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/22/2018 6/22/2018 at 1:00 PM 06/22/2018
Erosion Control Inspection Residential Failed 6/22/2018 06/22/2018
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/22/2018
DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL REQUIRED AROUND THE PILE OF DIRT NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 7/17/2018 7/17/2018 at 9:15 AM 07/17/2018
Piers/Caissons Inspection - Residential Failed 7/24/2018 (8:00) 7/24/2018 at 8:45 AM 07/24/2018
Misc
Corrective Action Required
07/24/2018
PROVIDE 24" DIA PIERS PER PLAN
Erosion Control Inspection Residential Failed 7/26/2018 07/26/2018
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/22/2018
DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL REQUIRED AROUND THE WHOLE LOT, INCLUDING THE PILE OF DIRT NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Piers/Caissons Inspection - Residential Passed 7/26/2018 7/26/2018 at 9:15 AM 07/26/2018
Rough Framing Inspection - Residential Failed 8/2/2018 8/2/2018 08/02/2018
Misc
Corrective Action Required
08/02/2018
GARAGE PORTAL - 2 CAR GARAGE -NAILING OF PLYWOOD OK HOLD DOWN STRAPS NOT INSTALLED 3RD CAR GARAGE NOT BUILT SITTING IN THE FEILD. TOLD THEM TO RECALL WHEN WALLS WERE COMPLETE OK TO SIDE ABOVE THE STONE LINE ON THE 2CAR WALL ...
Sewer Service Inspection - R Passed 9/20/2018 (11:30) 9/20/2018 at 10:45 AM 09/20/2018
Water Service Inspection - R Passed 9/20/2018 9/20/2018 at 2:20 PM 09/20/2018
Erosion Control Inspection Residential Failed 10/23/2018 10/23/2018 10/23/2018
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/26/2018
DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL REQUIRED AROUND THE WHOLE LOT, INCLUDING THE PILE OF DIRT INSPECTION DENIED. EROSION CONTROL MUST BE REPAIRED ALONG THE STREET. THE PILE OF DIRT FROM THIS LOT HAS NO EROSION CONTROL AROUND IT. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Failed 10/23/2018 10/23/2018 10/23/2018
Misc
Corrective Action Required
10/23/2018
**INSPECTION DENIED DUE TO LACK OF EROSION CONTROL. I COMPLAINED ABOUT THIS SEVERAL TIMES ALREADY. NO FURTHER INSPECTIONS UNTIL THE EROSION CONTROL IS IN COMPLIANCE. IN ADDITION, LEAVE THE CITY-APPROVED PLAN ON SITE FOR INSPECTION
Electrical Service Inspection Failed 10/23/2018 10/23/2018 10/23/2018
Misc
Corrective Action Required
10/23/2018
**INSPECTION DENIED **LOOK AT THE REBAR GROUNDING CONNECTION
Gas Service Inspection - Residential Failed 10/23/2018 10/23/2018 10/23/2018
Misc
Corrective Action Required
10/23/2018
**INSPECTION DENIED
Gas Service Inspection - Residential Passed 10/24/2018 10/24/2018 10/24/2018
Misc
Resolved
10/24/2018
**INSPECTION DENIED
Electrical Service Inspection Failed 10/24/2018 10/24/2018 10/24/2018
Misc
Corrective Action Required
10/23/2018
-REDO THE REBAR GROUNDING CONNECTION. THE GROUNDING ELECTRODE CONDUCTOR MUST BE WEDGED IN BETWEEN THE GROOVES OF THE GROUNDING CLAMP
All Rough Inspection - Residential Failed 10/24/2018 10/24/2018 10/24/2018
Misc
Corrective Action Required
10/23/2018
FRAMING: -Strap garage portal brace wall header per code; install 2” washers -Anchor sill plate within 12” of breaks -Strap cut top plate at garbage&entry wall intersection -The wall between the front bedrooms is not a bearing wall. Support roof per plan -Strap across cut wall top plates at front bedroom -Fb fireplace space from roof; Fb basement wall from ceiling fur-down space -Stud cut off at basement wet bar -Solid block joist ends above basement I beam -Seal penetrations of ceiling joist return air space -Solidblock underneath triple 18” LVL point load at rear end ELECTRICAL: -Move the master bed smoke alarm min 3 ft from fan blade -Complete wiring to living room wall receptacle -Protect wiring at living room rear wall bottom plate -Secure SE cable within 12” of meter enclosure -Fasten the wiring min 1.25” away from nailing surface along the stud near bottom stair landing -Complete wiring to basement wall receptacle and ceiling outlets -Bond gas piping PLUMBING: -Install stud shoes for studs bored more than 60% at basement bathroom -Bend the CSST gas line away from damage at rear basement bed ceiling. **OK TO INSULATE
Electrical Service Inspection Failed 10/31/2018 10/31/2018 10/31/2018
Misc
Corrective Action Required
10/24/2018
-REDO THE REBAR GROUNDING CONNECTION. THE GROUNDING ELECTRODE CONDUCTOR MUST BE WEDGED IN BETWEEN THE GROOVES OF THE GROUNDING CLAMP **LOCATE AND EXPOSE THE UFER CONNECTION. MUST BE ACCESSIBLE AT FINAL INSPECTION
All Rough Inspection - Residential Failed 10/31/2018 10/31/2018 at 8:10 AM 10/31/2018
Misc
Corrective Action Required
10/24/2018
FRAMING: -Strap across cut wall top plates at front bedroom **code requires that top plates be lapped no less than 24" or lapped at corner. In this case, the top plates are completely cut off at window -Stud cut off at basement wet bar **install 2x4 header underneath -Solid block joist ends above basement I beam **OK TO INSULATE
All Rough Inspection - Residential Failed 11/6/2018 11/6/2018 11/06/2018
Misc
Corrective Action Required
10/31/2018
FRAMING: -Stud cut off at basement wet bar **install 2x4 header underneath -Solid block joist ends above basement I beam (BEAM TO THE FRONT OF THE HOUSE AT UNFINISHED AREA) **OK TO INSULATE
Electrical Service Inspection Failed 11/6/2018 11/06/2018
Misc
Corrective Action Required
10/31/2018
-REDO THE REBAR GROUNDING CONNECTION. THE GROUNDING ELECTRODE CONDUCTOR MUST BE WEDGED IN BETWEEN THE GROOVES OF THE GROUNDING CLAMP **LOCATE AND EXPOSE THE UFER CONNECTION. MUST BE ACCESSIBLE AT FINAL INSPECTION STILL NOT VISIBLE OR ACCESSABLE
Electrical Service Inspection Passed 11/9/2018 11/9/2018 at 1:55 PM 11/09/2018
Misc
Resolved
11/09/2018
-REDO THE REBAR GROUNDING CONNECTION. THE GROUNDING ELECTRODE CONDUCTOR MUST BE WEDGED IN BETWEEN THE GROOVES OF THE GROUNDING CLAMP **LOCATE AND EXPOSE THE UFER CONNECTION. MUST BE ACCESSIBLE AT FINAL INSPECTION STILL NOT VISIBLE OR ACCESSABLE
All Rough Inspection - Residential Passed 11/9/2018 at 2:10 PM 11/09/2018
Misc
Resolved
11/09/2018
FRAMING: -Stud cut off at basement wet bar **install 2x4 header underneath -Solid block joist ends above basement I beam (BEAM TO THE FRONT OF THE HOUSE AT UNFINISHED AREA) **OK TO INSULATE
Driveway Inspection Partial 1/8/2019 (P.M.) 1/8/2019 at 1:30 PM 01/08/2019
Misc
Corrective Action Required
01/08/2019
Pre-pour inspection.
Driveway Inspection Passed 1/11/2019 04/25/2019
Misc
Corrective Action Required
01/08/2019
Pre-pour inspection.
Misc
Informational
04/25/2019
Final inspection passed
Rough Framing Inspection - Residential Passed 09/12/2019
Misc
Resolved
09/12/2019
Erosion Control Inspection Residential Passed 03/11/2020
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/11/2020
DEFICIENT EROSION CONTROL INSTALLATION. EROSION CONTROL REQUIRED AROUND THE WHOLE LOT, INCLUDING THE PILE OF DIRT INSPECTION DENIED. EROSION CONTROL MUST BE REPAIRED ALONG THE STREET. THE PILE OF DIRT FROM THIS LOT HAS NO EROSION CONTROL AROUND IT. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Occupancy Inspection - Codes Residential Failed 3/11/2020 at 9:50 AM 03/11/2020
Misc
Corrective Action Required
07/15/2019
-Lawn irrigation permit required -Raise AC platform min 3” above grade -Install tamper-proof caps at AC valves -Extend window well above grade -Seal exterior wall penetrations -Provide rear outdoor receptacle accessible from grade and within 6.5 ft of grade -Gas shut off valve for deck fireplace -Install box extension for floor receptacles to floor finish -Screw in the deck door embedded brace into stud -Install box extensions for switch & receptacle boxes recessed more than 1/4” behind kitchen countertop backsplash -Install water hammer arrestor for dish washer -Secure dish washer drain up high -Breaker lock for kitchen hood -Garage door not self closing -Install handrail for garage stair -Receptacle located within six ft of wet bar sink must be gfci-protected -Install anti-backflow device at basement hose bibb -Provide a receptacle in the unfinished basement -Locate and make accessible the ufer grounding connection
Occupancy Inspection - Codes Residential Temporary C of O 3/17/2020 3/17/2020 at 9:55 AM 03/17/2020
Misc
Corrective Action Required
03/11/2020
-Extend window well above grade
Occupancy Inspection - Codes Residential Full C of O 4/17/2020 04/17/2020
Misc
Resolved
04/17/2020
Documents & Images
Date Uploaded File Type Document Name
06/15/2018 Letter Codes Residential Plan Review
06/19/2018 Letter Codes Residential Plan Review
06/22/2018 Receipt Receipt for transaction: 2018-004140
06/22/2018 Letter Inspection Summary
06/22/2018 Letter Codes Building Permit
06/25/2018 Plot Plan DOC062518-06252018112532
07/17/2018 Letter Inspection Summary
07/24/2018 Letter Inspection Summary
07/26/2018 Letter Inspection Summary
08/02/2018 Letter Inspection Summary
09/20/2018 Letter Inspection Summary
10/23/2018 Letter Inspection Summary
10/23/2018 Letter Inspection Summary
10/23/2018 Letter Inspection Summary
10/23/2018 Letter Inspection Summary
10/23/2018 Letter Inspection Summary
10/24/2018 Letter Inspection Summary
10/24/2018 Letter Inspection Summary
10/24/2018 Letter Inspection Summary
10/31/2018 Letter Inspection Summary
10/31/2018 Letter Inspection Summary
11/06/2018 Letter Inspection Summary
11/06/2018 Letter Inspection Summary
11/09/2018 Letter Inspection Summary
11/09/2018 Letter Inspection Summary
01/08/2019 Letter DE-Daily Inspection Summary
04/25/2019 Letter INSPECTION SUMMARY
09/12/2019 Letter INSPECTION SUMMARY
03/11/2020 Letter INSPECTION SUMMARY
03/11/2020 Letter INSPECTION SUMMARY
03/12/2020 Engineer Report/Study ENGINEER REPORT
04/17/2020 Letter Codes Final Certificate of Occupancy
04/17/2020 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home