Summary
PRRES20173776
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
11/17/2017
11/22/2017
10/18/2018
Locations
Contacts
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 224-4760  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 11/21/2017 11/21/2017
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
11/17/2017

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) no square footage shown for unfinished basement or deck
07 Identify emergency escape openings from bedrooms
Corrective Action Required
11/17/2017

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
11/17/2017

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) no carbon monoxide detectors shown on the main level
10 Combustion air
Corrective Action Required
11/17/2017

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
11/17/2017

Identify roof covering material (IRC Section R905)
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
11/17/2017

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
11/17/2017

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Approved 11/21/2017 11/17/2017
Troy Thompson
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $873.61 $873.61 Paid 11/22/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 11/22/2017
8331507-Sewer Connection Fee $420.00 $420.00 Paid 11/22/2017
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 11/22/2017
8350015-Water Meter Fee $431.83 $431.83 Paid 11/22/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 12/1/2017 12/01/2017
Misc
Corrective Action Required
12/01/2017
-EROSION CONTROL REQUIRED ALONG THE SIDE -GRAVEL FILTER SHALL BE PROVIDED AT ENTRANCE TO LOT ****NO FURTHER INSPECTION IF EROSION CONTROL IS NOT IN COMPLIANCE
Footing Inspection - Residential Passed 12/1/2017 (8:30) 12/1/2017 at 9:45 AM 12/01/2017
Underslab Plumbing Inspection - Residential Passed 12/21/2017 12/21/2017 at 9:10 AM 12/21/2017
Piers/Caissons Inspection - Residential Passed 1/29/2018 (1:00) 1/29/2018 at 1:05 PM 01/29/2018
Sewer Service Inspection - R Passed 3/2/2018 at 3:10 PM 03/02/2018
Water Service Inspection - R Passed 3/5/2018 3/5/2018 at 2:00 PM 03/05/2018
All Rough Inspection - Residential Failed 3/20/2018 3/20/2018 at 8:35 AM 03/20/2018
Miscellaneous Correction
Corrective Action Required
03/20/2018
FRAMING: -Anchor sill plate near garage I beam support; anchor within 12” of break -Fb b vent chase from roof -Fb fireplace space from roof -Fb foyer wall from roof -Have engineer check roof support beam size above front bed -Fb stair wall from roof -Install hangers for ceiling joist-lvl connections above kitchen. Kitchen wall not bearing wall -Fb basement wall space from furdown space at bath and bed closet and west side of basement -Shim in gap at basement exterior door at strike plate side per security code -Plan calls for triple LVL beam below foyer. PLUMBING: -Protect washer drain in laundry ELECTRICAL: -Protect laundry circuit -Protect wiring at basement bath wall top plate **OK TO INSULATE
Electrical Service Inspection Passed 3/20/2018 3/20/2018 03/20/2018
Gas Service Inspection - Residential Passed 3/20/2018 3/20/2018 03/20/2018
All Rough Inspection - Residential Failed 3/22/2018 3/22/2018 at 9:50 AM 03/22/2018
Miscellaneous Correction
Corrective Action Required
03/20/2018
FRAMING: -Have engineer check roof support beam size above front bed -Plan calls for triple LVL beam below foyer. **OK TO INSULATE
Driveway Inspection Partial 3/22/2018 at 11:20 AM 03/22/2018
Informational
03/22/2018
Jeremy Young 03/22/2018 11:45 AM Contractor has sufficient compacted rock at least 4" there is a clean joint at the ROW line. The cross slope for the ADA requirements are between .05-1.0%. There will be at least 6" of concrete for the ROW.
Sidewalk Inspection Partial 3/22/2018 at 11:30 AM 03/22/2018
Informational
03/22/2018
Jeremy Young 03/22/2018 11:49 AM Contractor has at least 4" compacted rock. The cross slope is between .04-1.2% through out the sidewalk which meets ADA requirements.
Sidewalk Inspection Passed 3/28/2018 at 9:35 AM 03/28/2018
PW-Misc
Informational
03/28/2018
Jeremy Young 03/28/2018 9:36 AM Contractor has poured concrete. There is at least 6" of rock in the ROW. The cross slope is between 1.1-1.9% through the sidewalk.
Driveway Inspection Passed 3/28/2018 at 9:40 AM 03/28/2018
Informational
03/28/2018
Jeremy Young 03/28/2018 3:07 PM Contractor poured the driveway. There is at least 6" of concrete at the approach. The expansion joint is present. The cross slope is less than 2% which meets ADA standard.
Occupancy Inspection - Codes Residential Failed 6/19/2018 6/19/2018 at 8:00 AM 06/19/2018
Misc
Corrective Action Required
06/19/2018
-FINAL GRADE, SOD, SPLASHBLOCKS -ALL-ROUGH INSPECTION NOT APPROVED -SEAL EXTERIOR LIGHT AT REAR -INSTALL BOX EXTENSIONS AT FLOOR RECEPTACLES -COMPLETE KITCHEN. INSTALL COOKTOP -INSTALL ANTI-BACKFLOW DEVICE FOR THE BASEMENT HOSE BIBB -SECURE WATER SERVICE LINE -SUPPORT GAS PIPING -PROVIDE COMBUSTION AIR OPENINGS PER CODE THE THE WATER HEATER
All Rough Inspection - Residential Passed 06/21/2018
Miscellaneous Correction
Resolved
06/21/2018
FRAMING: -Have engineer check roof support beam size above front bed -Plan calls for triple LVL beam below foyer. **OK TO INSULATE
Occupancy Inspection - Codes Residential Temporary C of O 6/21/2018 at 9:00 AM 06/21/2018
Misc
Corrective Action Required
06/19/2018
-FINAL GRADE, SOD, SPLASHBLOCKS
Erosion Control Inspection Residential Passed 10/18/2018
Misc
Resolved
06/21/2018
-EROSION CONTROL REQUIRED ALONG THE SIDE -GRAVEL FILTER SHALL BE PROVIDED AT ENTRANCE TO LOT ****NO FURTHER INSPECTION IF EROSION CONTROL IS NOT IN COMPLIANCE
Occupancy Inspection - Codes Residential Full C of O 10/18/2018 at 2:25 PM 10/18/2018
Misc
Resolved
10/18/2018
-FINAL GRADE, SOD, SPLASHBLOCKS
Documents & Images
Date Uploaded File Type Document Name
11/17/2017 Letter Codes Residential Plan Review
11/22/2017 Receipt Receipt for transaction: 2017-007393
11/22/2017 Letter Codes Building Permit
11/22/2017 Plot Plan DOC112217-011
12/01/2017 Letter Inspection Summary
12/21/2017 Letter Inspection Summary
01/29/2018 Letter Inspection Summary
03/02/2018 Letter Inspection Summary
03/05/2018 Letter Inspection Summary
03/20/2018 Letter Inspection Summary
03/22/2018 Letter Inspection Summary
03/22/2018 Letter DE-Daily Inspection Summary
03/22/2018 Letter DE-Daily Inspection Summary
03/28/2018 Letter DE-Daily Inspection Summary
03/28/2018 Letter DE-Daily Inspection Summary
06/19/2018 Letter Inspection Summary
06/21/2018 Letter Codes Temporary Certificate of Occupancy
10/18/2018 Letter Field Certificate of Occupancy
10/19/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home