Permit Application Status

PRRES20173195


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20173195
Building Permit - Residential
Certificate of Occupancy
MCGRAW HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - FINISHED BASEMENT
09/25/2017
10/10/2017
09/07/2018
Locations
Contacts
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/27/2017 09/27/2017
Kim Brennan
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
09/25/2017

Identify roof covering material (IRC Section R905)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
09/25/2017

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Plot Plan Review Approved 09/27/2017 09/25/2017
Nick Lightner
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,083.82 $1,083.82 Paid 10/10/2017
Right of Way Permit Fee $75.00 $75.00 Paid 10/10/2017
8331507-Sewer Connection Fee $540.00 $540.00 Paid 10/10/2017
Water Tap Fee $3,343.00 $3,343.00 Paid 10/10/2017
Water Meter Fee $431.83 $431.83 Paid 10/10/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 10/11/2017 at 2:00 PM 10/11/2017
Misc
Corrective Action Required
10/11/2017
INSTALL GRAVEL CONSTRUCTION ACCESS
Footing Inspection - Residential Passed 10/11/2017 10/11/2017 at 2:11 PM 10/11/2017
Erosion Control Inspection Residential Failed 10/31/2017 at 3:30 PM 10/31/2017
Misc
Corrective Action Required
10/11/2017
PROTECT NORTH SIDE OF PROPERTY
Underslab Plumbing Inspection - Residential Passed 10/31/2017 10/31/2017 at 3:36 PM 10/31/2017
Piers/Caissons Inspection - Residential Passed 12/18/2017 12/18/2017 at 8:35 AM 12/18/2017
Erosion Control Inspection Residential Failed 12/18/2017 12/18/2017
Misc
Corrective Action Required
10/31/2017
PROTECT NORTH SIDE OF PROPERTY
All Rough Inspection - Residential Failed 1/31/2018 1/31/2018 at 9:10 AM 01/31/2018
Misc
Corrective Action Required
01/31/2018
FRAMING: -Close floor opening @ front bed closet -Support front of ridge @ front bed -Support hips above master bed -Security blocking for deck door and basement door -Fb wall from furdown space above rear basement bed closet; Fb basement bath wall from furdown space MECHANICAL: -Min 1” clearance around b vent -Lower supply duct to ceiling level at front basement bed -Overspanned dryer duct ELECTRICAL: -Complete electrical to entry stoop light -Provide wall receptacle spacing peer code in office -Complete electrical to ceiling lights in office -Protect wiring at rear basement bed closet -Secure wiring per code @ rear basement bed switch -Above front basement bed closet, move the wiring away from touching the dryer duct ***OK TO INSULATE
Gas Service Inspection - Residential Passed 1/31/2018 1/31/2018 01/31/2018
Electrical Service Inspection Passed 1/31/2018 1/31/2018 01/31/2018
All Rough Inspection - Residential Failed 2/2/2018 2/2/2018 at 10:55 AM 02/02/2018
Misc
Corrective Action Required
01/31/2018
FRAMING: -Fb basement bath wall from furdown space **I need more insulation to fb the wall at tub and sink MECHANICAL: -Overspanned dryer duct **the duct spans quite a bit with too many elbows. 22-23 ft with five 90 deg elbows ***OK TO INSULATE
All Rough Inspection - Residential Passed 2/5/2018 2/5/2018 at 8:50 AM 02/05/2018
Misc
Resolved
02/05/2018
FRAMING: -Fb basement bath wall from furdown space **I need more insulation to fb the wall at tub and sink MECHANICAL: -Overspanned dryer duct **the duct spans quite a bit with too many elbows. 22-23 ft with five 90 deg elbows ***OK TO INSULATE
Water Service Inspection - R Passed 2/14/2018 at 11:55 AM 02/14/2018
Sewer Service Inspection - R Passed 2/14/2018 at 11:50 AM 02/14/2018
Driveway Inspection Partial 3/1/2018 3/1/2018 at 2:20 PM 03/01/2018
Informational
03/01/2018
Jeremy Young 03/01/2018 2:36 PM inspected the pre-pour for the driveway. There appears to be at least 4" of compacted rock. The total driveway width is approx 35' which is within our specs. The contractor will add expansion joints while pouring.
Driveway Inspection Passed 3/7/2018 at 1:00 PM 03/07/2018
Informational
03/07/2018
Jeremy Young 03/07/2018 1:04 PM Re-inspected the driveay after the concrete pour. The contractor added the expansion joints. It appears there is 6" of concrete in the right of way. There is no sidewalk or ADA issues.
Erosion Control Inspection Residential Passed 06/04/2018
Misc
Resolved
06/04/2018
PROTECT NORTH SIDE OF PROPERTY
Occupancy Inspection - Codes Residential Failed 6/4/2018 6/4/2018 at 2:20 PM 06/04/2018
Misc
Corrective Action Required
06/04/2018
-OBTAIN IRRIGATION PERMIT -SOD, SPLASHBLOCKS -WATER METER TO LID DISTANCE OUTSIDE OF COMPLIANCE (MORE THAN 18"). GET APPROVAL FROM WATER METER DEPT -SECURE AC WHIP. ALSO CHECK EXCESSIVE VIBRATION OF MOTOR/FAN -COMPLETE KITCHEN
Occupancy Inspection - Codes Residential Temporary C of O 6/6/2018 6/6/2018 at 9:35 AM 06/06/2018
Misc
Corrective Action Required
06/04/2018
-WATER METER TO LID DISTANCE OUTSIDE OF COMPLIANCE (MORE THAN 18"). GET APPROVAL FROM WATER METER DEPT
Occupancy Inspection - Codes Residential Full C of O 9/7/2018 09/07/2018
Misc
Resolved
09/07/2018
-WATER METER TO LID DISTANCE OUTSIDE OF COMPLIANCE (MORE THAN 18"). GET APPROVAL FROM WATER METER DEPT
Documents & Images
Date Uploaded File Type Document Name
09/25/2017 Letter Codes Residential Plan Review
10/10/2017 Receipt Receipt for transaction: 2017-006751
10/10/2017 Letter Codes Building Permit
10/11/2017 Letter Inspection Summary
10/11/2017 Plot Plan DOC101117-001
10/31/2017 Letter Inspection Summary
12/18/2017 Letter Inspection Summary
01/31/2018 Letter Inspection Summary
02/02/2018 Letter Inspection Summary
02/05/2018 Letter Inspection Summary
02/14/2018 Letter Inspection Summary
03/01/2018 Letter DE-Daily Inspection Summary
03/07/2018 Letter DE-Daily Inspection Summary
06/04/2018 Letter Inspection Summary
06/06/2018 Letter Codes Temporary Certificate of Occupancy
09/07/2018 Letter Field Certificate of Occupancy
09/10/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home