Permit Application Status

PRRES20173192


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20173192
Building Permit - Residential
Certificate of Occupancy
MCGRAW HOMES INC
NEW SINGLE FAMILY
NEW HOUSE COVERED DECK AND FINISHED BASEMENT
09/22/2017
10/10/2017
06/11/2018
Locations
Contacts
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 09/27/2017 09/27/2017
Kim Brennan
06 Designate use of each room or space
Corrective Action Required
09/25/2017

Designate use of each room or space including but not limited to; basement storage, garages, and attic areas intended for storage space. No designation in the basement area.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
09/25/2017

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) in the basement
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
09/25/2017

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) in the basement
14 Identify roof covering material (IRC Section R905)
Corrective Action Required
09/25/2017

Identify roof covering material (IRC Section R905)
Plot Plan Review Approved 09/26/2017 09/26/2017
Nick Lightner
Property boundary
Resolved
09/26/2017

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. *Can you please double check the rear property boundary.
Sidewalks
Resolved
09/26/2017

Sidewalks with deminsions must be provided on the plot plan. *Can you please provide the 5ft sidewalk to the plot plan.
City infrustructure
Resolved
09/26/2017

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. *Can you please show the fire hydrant on the plot plan and make sure that its not in the driveway location.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $872.90 $872.90 Paid 10/10/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 10/10/2017
8331507-Sewer Connection Fee $360.00 $360.00 Paid 10/10/2017
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 10/10/2017
8350015-Water Meter Fee $431.83 $431.83 Paid 10/10/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/13/2017 (8:00) 10/13/2017 at 8:50 AM 10/13/2017
Underslab Plumbing Inspection - Residential Failed 11/7/2017 11/7/2017 at 9:35 AM 11/07/2017
Misc
Corrective Action Required
11/07/2017
NOT READY ***INSPECTION DENIED. INSTALL EROSION CONTROL PER CITY REQUIREMENT
Erosion Control Inspection Residential Failed 11/7/2017 11/07/2017
Misc
Corrective Action Required
11/07/2017
***INSPECTION DENIED. INSTALL EROSION CONTROL PER CITY REQUIREMENT
Underslab Plumbing Inspection - Residential Passed 11/8/2017 11/8/2017 at 9:15 AM 11/08/2017
Misc
Resolved
11/08/2017
NOT READY
Erosion Control Inspection Residential Passed 11/8/2017 11/08/2017
Misc
Resolved
11/08/2017
***INSPECTION DENIED. INSTALL EROSION CONTROL PER CITY REQUIREMENT
Sewer Service Inspection - R Passed 12/22/2017 at 2:50 PM 12/22/2017
Water Service Inspection - R Passed 1/19/2018 at 1:30 PM 01/19/2018
Piers/Caissons Inspection - Residential Passed 1/29/2018 (1:00) 1/29/2018 at 1:10 PM 01/29/2018
Electrical Service Inspection Passed 2/14/2018 2/14/2018 02/14/2018
All Rough Inspection - Residential Failed 2/14/2018 2/14/2018 at 1:50 PM 02/14/2018
Misc
Corrective Action Required
02/14/2018
FRAMING: -ANCHOR ALL SILL PLATES WITHIN 12" OF BREAKS -BRACE LVL BEAM ENDS FROM ROTATION -FIREBLOCK THE FIREPLACE SPACE FROM ROOF AT BOTH SIDES -PROVIDE FULL BEARING SUPPORT OF THE KITCHENTRIPLE LVL AND BEARING WALL DOWN TO GRADE BEAM AT STAIR. THIS GRADE BEAM IS TO CARRY THE LOAD, NOT THE DOUBLE JOIST -INSTALL JOIST HANGER NEAR GAS PIPING ENTRY INTO HOUSE -INSTALL HNAGERS FOR JOISTS SUPPORT AT REAR BASEMENT WALL ABOVE WINDOW -ANCHOR ALL BASEMENT COLUMNS -FB WALL SPACE FROM I BEAM FURDOWN AT REAR OF BASEMENT -INSTALL FULL SUPPORT FOR THE DOUBLE JOIST AND I BEAM BELOW FIREPLACE -INSTALL A DOUBLE 2X10 BEAM UNDERNEATH THE POINT LOADS OF THE CEILING BEAM CARRYING THE WALL&ROOF LOAD ABOVE LAUNDRY. NEXT TIME, EXTEND THE DOUBLE JOIST BEAM TO THE BEARING WALL OF FOYER CLOSET MECHANICAL: -PROVIDE MIN. 1" SPACE AROUND THE B-VENT AND THE FIREPLACE DIRECT VENT IN ATTIC PLUMBING: -PROTECT PLUMBING AT TOP OF WALL IN BASEMENT BATH ELECTRCIAL: -COMPLETE ELECTRICAL AT REFRIGERATOR WALL -SECURELY FASTEN ALL NM WIRING EVERY 4.5 FT IN BASEMENT. CANNOT JUST LET THEM REST ON THE CEILING FRAMING -PROTECT WIRING AT CEILING/WALL INTERSECTION OUTSIDE BASEMENT BED ***DO NOT INSULATE
Gas Service Inspection - Residential Passed 2/14/2018 2/14/2018 02/14/2018
All Rough Inspection - Residential Passed 2/16/2018 2/16/2018 at 10:30 AM 02/16/2018
Misc
Resolved
02/16/2018
FRAMING: -ANCHOR ALL SILL PLATES WITHIN 12" OF BREAKS -BRACE LVL BEAM ENDS FROM ROTATION -FIREBLOCK THE FIREPLACE SPACE FROM ROOF AT BOTH SIDES -PROVIDE FULL BEARING SUPPORT OF THE KITCHENTRIPLE LVL AND BEARING WALL DOWN TO GRADE BEAM AT STAIR. THIS GRADE BEAM IS TO CARRY THE LOAD, NOT THE DOUBLE JOIST -INSTALL JOIST HANGER NEAR GAS PIPING ENTRY INTO HOUSE -INSTALL HNAGERS FOR JOISTS SUPPORT AT REAR BASEMENT WALL ABOVE WINDOW -ANCHOR ALL BASEMENT COLUMNS -FB WALL SPACE FROM I BEAM FURDOWN AT REAR OF BASEMENT -INSTALL FULL SUPPORT FOR THE DOUBLE JOIST AND I BEAM BELOW FIREPLACE -INSTALL A DOUBLE 2X10 BEAM UNDERNEATH THE POINT LOADS OF THE CEILING BEAM CARRYING THE WALL&ROOF LOAD ABOVE LAUNDRY. NEXT TIME, EXTEND THE DOUBLE JOIST BEAM TO THE BEARING WALL OF FOYER CLOSET MECHANICAL: -PROVIDE MIN. 1" SPACE AROUND THE B-VENT AND THE FIREPLACE DIRECT VENT IN ATTIC PLUMBING: -PROTECT PLUMBING AT TOP OF WALL IN BASEMENT BATH ELECTRCIAL: -COMPLETE ELECTRICAL AT REFRIGERATOR WALL -SECURELY FASTEN ALL NM WIRING EVERY 4.5 FT IN BASEMENT. CANNOT JUST LET THEM REST ON THE CEILING FRAMING -PROTECT WIRING AT CEILING/WALL INTERSECTION OUTSIDE BASEMENT BED ***DO NOT INSULATE
Driveway Inspection Partial 3/7/2018 3/7/2018 at 9:10 AM 03/07/2018
Informational
03/07/2018
Jeremy Young 03/07/2018 9:24 AM Met with the contractor on site. There is sufficient compacted rock base, at least 4". The contractor will add expansion joint while pouring. No sidewalk coming through the property. Will re-inspect.
Driveway Inspection Passed 3/12/2018 at 11:10 AM 03/09/2018
Informational
03/09/2018
Jeremy Young 03/09/2018 11:14 AM Contractor has poured the approach. There is at least 6" of concrete. The expansion joint has been added and the driveway is less than the 36' limit.
Occupancy Inspection - Codes Residential Failed 4/20/2018 at 9:06 AM 04/20/2018
Misc
Corrective Action Required
04/20/2018
-OBTAIN LAWN IRRIGATION PERMIT AND SUBMIT TO CITY THE BACKFLOW TEST REPORT -FINAL GRADE, SOD, SPLASHBLOCKS -SEAL EXTERIOR: PENETRATIONS, ABOVE METER, AC DISCONNECT, ETC -GARAGE DOOR NOT SELF-CLOSING
Occupancy Inspection - Codes Residential Full C of O 6/11/2018 6/11/2018 at 9:10 AM 06/11/2018
Misc
Resolved
06/11/2018
-FINAL GRADE, SOD, SPLASHBLOCKS -SEAL EXTERIOR: PENETRATIONS, ABOVE METER, AC DISCONNECT, ETC -GARAGE DOOR NOT SELF-CLOSING
Documents & Images
Date Uploaded File Type Document Name
09/25/2017 Letter Codes Residential Plan Review
10/10/2017 Receipt Receipt for transaction: 2017-006753
10/10/2017 Letter Codes Building Permit
10/11/2017 Plot Plan DOC101117-002
10/13/2017 Letter Inspection Summary
11/07/2017 Letter Inspection Summary
11/08/2017 Letter Inspection Summary
12/22/2017 Letter Inspection Summary
01/19/2018 Letter Inspection Summary
01/29/2018 Letter Inspection Summary
02/14/2018 Letter Inspection Summary
02/16/2018 Letter Inspection Summary
03/07/2018 Letter DE-Daily Inspection Summary
03/09/2018 Letter DE-Daily Inspection Summary
04/20/2018 Letter Inspection Summary
06/11/2018 Letter Field Certificate of Occupancy
06/12/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home