Summary
PRRES20172899
Building Permit - Residential
Certificate of Occupancy
MCGRAW HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - FINISHED BASEMENT
08/29/2017
08/31/2017
03/07/2018
Locations
Contacts
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 08/31/2017 08/31/2017
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
08/29/2017

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) in the master bedroom and bedroom #2
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
08/29/2017

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) no carbon monoxide detectors found in the immediate vicinity of each sleeping room
12 Detail required separation between garage and living area including door
Corrective Action Required
08/29/2017

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5)
15 Provide size, spacing, species, and grade of rafter, ceiling joist mater
Corrective Action Required
08/29/2017

Provide size, spacing, species, and grade of rafter, ceiling joist materials and ridge and valley members. (IRC Section R802)
17 Specification of rafter ties or ridge beam design.
Corrective Action Required
08/29/2017

Specification of rafter ties or ridge beam design. (IRC Section 802.3.1)
20 Footings, column pads, piers and grade beams - reinforcement
Corrective Action Required
08/29/2017

Footings, column pads, piers and grade beams - reinforcement size and spacing.
23 Location of vertical supports for beams. (point loads)
Corrective Action Required
08/29/2017

Location of vertical supports for beams. (point loads)
26 Concrete minimum compressive strength.
Corrective Action Required
08/29/2017

Concrete minimum compressive strength. (IRC Section 402.2)
36 Identify interior load bearing walls.
Corrective Action Required
08/29/2017

Identify interior load bearing walls. (IRC Section R602)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
08/29/2017

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1)
Misc
Corrective Action Required
08/29/2017

Electrical contractor does not have a business license
Plot Plan Review Approved 08/31/2017 08/29/2017
Nick Lightner
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,005.17 $1,005.17 Paid 08/31/2017
Right of Way Permit Fee $75.00 $75.00 Paid 08/31/2017
8331507-Sewer Connection Fee $450.00 $450.00 Paid 08/31/2017
Water Tap Fee $3,343.00 $3,343.00 Paid 08/31/2017
Water Meter Fee $431.83 $431.83 Paid 08/31/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/5/2017 09/05/2017
Erosion Control Inspection Residential Failed 9/5/2017 09/05/2017
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/05/2017
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Failed 9/18/2017 9/18/2017 09/18/2017
Misc
Corrective Action Required
09/18/2017
-PROVIDE MIN. 1/8" PER FT SLOPE. SOME SECTION OF BUILDING DRAIN ACTUALLY SLOPES BACKWARD
Underslab Plumbing Inspection - Residential Passed 9/19/2017 9/19/2017 at 3:25 PM 09/19/2017
Misc
Resolved
09/19/2017
-PROVIDE MIN. 1/8" PER FT SLOPE. SOME SECTION OF BUILDING DRAIN ACTUALLY SLOPES BACKWARD
Suspended Slab Inspection Passed 11/13/2017 at 2:30 PM 11/13/2017
Electrical Service Inspection Passed 12/12/2017 12/12/2017 12/12/2017
Gas Service Inspection - Residential Passed 12/12/2017 12/12/2017 12/12/2017
All Rough Inspection - Residential Failed 12/12/2017 12/12/2017 at 9:35 AM 12/12/2017
Misc
Corrective Action Required
12/12/2017
FRAMING: -Strap inner side of garage portal walls, or add more nailing to H-frame -Move roof support above master closet/laundry wall to bearing wall -Fireblock fireplace space -Security block both rear doors -Missing support steel column for I beam in mech rm PLUMBING: -Protect plumbing at pantry ELECTRICAL: -Receptacle within 25 ft if ac -Secure both se cables within 12” of meter , pool disconnect, and panel ***OK TO INSULATE
All Rough Inspection - Residential Passed 12/14/2017 12/14/2017 at 8:45 AM 12/14/2017
Misc
Resolved
12/14/2017
FRAMING: -Strap inner side of garage portal walls, or add more nailing to H-frame -Move roof support above master closet/laundry wall to bearing wall -Fireblock fireplace space -Security block both rear doors -Missing support steel column for I beam in mech rm PLUMBING: -Protect plumbing at pantry ELECTRICAL: -Receptacle within 25 ft if ac -Secure both se cables within 12” of meter , pool disconnect, and panel ***OK TO INSULATE
Piers/Caissons Inspection - Residential Passed 12/18/2017 12/18/2017 at 8:30 AM 12/18/2017
Sewer Service Inspection - R Passed 2/12/2018 2/12/2018 02/14/2018
Water Service Inspection - R Passed 2/14/2018 2/14/2018 at 3:25 PM 02/14/2018
Driveway Inspection Partial 2/27/2018 2/27/2018 at 8:15 AM 02/27/2018
Informational
02/27/2018
Jeremy Young 02/27/2018 8:36 AM Met with the contractor on site. The driveway has sufficient rock base at least 4" compacted rock. I checked the slope through the driveway and there was approx 1.4-1.6% slope through the driveway. The contractor added rebar and expansion joints at the curb.
Sidewalk Inspection Partial 2/27/2018 2/27/2018 at 8:25 AM 02/27/2018
PW-Misc
Informational
02/27/2018
Jeremy Young 02/27/2018 8:41 AM Met the contractor on site. The sidewalk has sufficient rock base at least 4" compacted material. I checked the cross slope and there was approx 1.4-1.6% all the way through the sidewalk.
Erosion Control Inspection Residential Failed 3/5/2018 at 9:10 AM 03/05/2018
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/05/2017
REQUESTED INSPECTION DENIED. NO EROSION CONTROL IN PLACE.
Occupancy Inspection - Codes Residential Not Ready 3/5/2018 at 9:16 AM 03/05/2018
Misc
Corrective Action Required
03/05/2018
DENIED DUE TO LACK OF EROSION CONTROL.
Driveway Inspection Passed 3/6/2018 at 2:05 PM 03/05/2018
Informational
03/05/2018
Jeremy Young 03/05/2018 3:38 PM Inspected the driveway pour for the property. The cross slope between the sidewalk was between .04-1.8% which is within specs for ADA. There is a solid joint between the right of way and the other driveway. The contractor had placed the expansion joint between the curb and driveway.
Sidewalk Inspection Passed 3/6/2018 at 2:05 PM 03/05/2018
PW-Misc
Informational
02/27/2018
Jeremy Young 02/27/2018 8:41 AM Met the contractor on site. The sidewalk has sufficient rock base at least 4" compacted material. I checked the cross slope and there was approx 1.4-1.6% all the way through the sidewalk.
PW-Misc
Informational
03/05/2018
Jeremy Young 03/05/2018 3:43 PM Inspected the sidewalk after the concrete pour. The contractor met the ADA standards. He was between .04-1.8% cross slope. The contractor used the correct concrete.
Erosion Control Inspection Residential Passed 3/6/2018 at 12:20 PM 03/06/2018
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/06/2018
REQUESTED INSPECTION DENIED. NO EROSION CONTROL IN PLACE.
Occupancy Inspection - Codes Residential Failed 3/6/2018 at 12:31 PM 03/06/2018
Misc
Corrective Action Required
03/05/2018
-INSTALL PANNELBOARD FRONT TIGHT PER MANUFACTORER -FIRECAULK PLUMBING PENETRATIONS IN GARAGE -RECEPTACLE NEXT TO FURNACE NEEDS TO BE GFCI PROTECTED
Occupancy Inspection - Codes Residential Full C of O 3/7/2018 at 8:00 AM 03/07/2018
Misc
Resolved
03/07/2018
-INSTALL PANNELBOARD FRONT TIGHT PER MANUFACTORER -FIRECAULK PLUMBING PENETRATIONS IN GARAGE -RECEPTACLE NEXT TO FURNACE NEEDS TO BE GFCI PROTECTED
Documents & Images
Date Uploaded File Type Document Name
08/29/2017 Letter Codes Residential Plan Review
08/31/2017 Receipt Receipt for transaction: 2017-006155
08/31/2017 Letter Codes Building Permit
09/05/2017 Letter Inspection Summary
09/05/2017 Plot Plan DOC090517-013
09/18/2017 Letter Inspection Summary
09/19/2017 Letter Inspection Summary
11/13/2017 Letter Inspection Summary
12/12/2017 Letter Inspection Summary
12/14/2017 Letter Inspection Summary
12/18/2017 Letter Inspection Summary
02/12/2018 Letter Inspection Summary
02/14/2018 Letter Inspection Summary
02/27/2018 Letter Inspection Summary
03/05/2018 Letter Inspection Summary
03/05/2018 Letter DE-Daily Inspection Summary
03/05/2018 Letter DE-Daily Inspection Summary
03/06/2018 Letter Inspection Summary
03/07/2018 Letter Field Certificate of Occupancy
03/14/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home