Permit Application Status

PRRES20172649


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20172649
Building Permit - Residential
Certificate of Occupancy
RAINTREE LAKE PROPERTY OWNERS ASSOC INC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK/UNCOVERED DECK - FINISHED BASEMENT
08/01/2017
05/25/2018
07/26/2019
Locations
Contacts
LANDROCK SIGNATURE HOMES LLC, Address:4335 MCGEE ST, Phone:(816) 863-5588  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
RAINTREE LAKE PROPERTY OWNERS ASSOC INC, Address:825 SW RAINTREE DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/03/2017 05/25/2018
Steve Conrick
City infrustructure
Corrective Action Required
08/31/2017

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. *Can you please provide all city infrastructure to the plot plan.
Residential Plan Review Approved 08/03/2017 11/30/2017
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
08/01/2017

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) Outside the master bedroom, bedroom #2 and #4
10 Combustion air
Corrective Action Required
08/01/2017

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407) for upstairs furnace
30 Identify type of protection used in unfinished areas under
Corrective Action Required
08/01/2017

Identify type of protection used in unfinished areas under floor trusses. (IRC Section R501.3)
31 Identify type of joist package or floor truss package (if used)
Corrective Action Required
08/01/2017

Identify type of joist package or floor truss package (if used) complete with layouts, fastening details, blocking and bracing requirements and minimum sheathing.
23 Location of vertical supports for beams. (point loads)
Corrective Action Required
08/01/2017

Location of vertical supports for beams. (point loads)
Misc
Corrective Action Required
08/01/2017

Since using 400 amp, please provide riser diagram with wire grounding sizes and methods.
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,679.71 $1,679.71 Paid 05/25/2018
Right of Way Permit Fee $75.00 $75.00 Paid 05/25/2018
8331507-Sewer Connection Fee $630.00 $630.00 Paid 05/25/2018
Water Tap Fee $3,343.00 $3,343.00 Paid 05/25/2018
Water Meter Fee $431.83 $431.83 Paid 05/25/2018
Valuation Fee New Single Family $293.73 $293.73 Paid 02/06/2019
$1,973.44
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/13/2018 (8:15) 6/13/2018 at 8:45 AM 06/13/2018
Foundation Inspection - Residential Passed 6/26/2018 6/26/2018 at 3:00 PM 06/26/2018
Underslab Plumbing Inspection - Residential Failed 7/20/2018 7/20/2018 at 8:00 AM 07/20/2018
Misc
Corrective Action Required
07/20/2018
-INTERIOR DRAINAGE TILE IS RUNNING OVER TOP OF THE PLUMBING IN 2 LOCATIONS
Underslab Plumbing Inspection - Residential Passed 7/23/2018 7/23/2018 at 8:30 AM 07/23/2018
Misc
Resolved
07/23/2018
Sewer Service Inspection - R Passed 1/10/2019 1/10/2019 at 3:00 PM 01/10/2019
Misc
Informational
01/10/2019
clean out at 100' mark tracer wire present OK TO COVER
Water Service Inspection - R Passed 1/11/2019 (10:00) 1/11/2019 at 10:31 AM 01/11/2019
All Rough Inspection - Residential Failed 2/5/2019 at 1:15 PM 02/05/2019
Misc
Corrective Action Required
02/05/2019
1. Address rear master header. 2. Install 5 studs 1st floor next to bottom of the stairs. 3. Nail exterior corner studs minimum 12” o.c. 4. Vent bath fans. 5. Protect water lines at bottom plates. 6. North end of LVL carrying roof load, provide stud support through. 7. 2nd floor SW bedroom, strap top plate cut for supply ducts at north wall. 8. Nail all LVL beams together from both sides. Check all. 9. Vent kitchen sink. 10. Seal penetrations in draft stops for 1st floor joists.
Gas Service Inspection - Residential Passed 2/5/2019 at 2:46 PM 02/05/2019
Gas Piping Inspection - Residential Passed 2/5/2019 at 2:51 PM 02/05/2019
All Rough Inspection - Residential Passed 2/12/2019 2/12/2019 at 7:30 AM 02/12/2019
Misc
Resolved
02/12/2019
1. Address rear master header. 2. Install 5 studs 1st floor next to bottom of the stairs. 3. Nail exterior corner studs minimum 12” o.c. 4. Vent bath fans. 5. Protect water lines at bottom plates. 6. North end of LVL carrying roof load, provide stud support through. 7. 2nd floor SW bedroom, strap top plate cut for supply ducts at north wall. 8. Nail all LVL beams together from both sides. Check all. 9. Vent kitchen sink. 10. Seal penetrations in draft stops for 1st floor joists.
Driveway Inspection Partial 5/6/2019 (P.M.) 5/6/2019 at 1:30 PM 05/07/2019
Misc
Informational
05/07/2019
It appears that 4 inches of rock has been installed, they were a little short on the 6" of depth so I waited while they dug out some more to acheive the 6" of depth.
Driveway Inspection Passed 5/14/2019 at 10:20 AM 05/14/2019
Misc
Informational
05/07/2019
It appears that 4 inches of rock has been installed, they were a little short on the 6" of depth so I waited while they dug out some more to acheive the 6" of depth.
Misc
Informational
05/14/2019
The driveway has been poured and it appears to meet the city standards.
Electrical Service Inspection Passed 6/28/2019 6/28/2019 at 3:00 PM 06/27/2019
Misc
Corrective Action Required
06/27/2019
panels are ok. race way to meter needs to be moved to other side of meter and secured. ok for kcpl service when raceway is moved.
Occupancy Inspection - Codes Residential Failed 6/28/2019 6/28/2019 at 3:00 PM 06/28/2019
Misc
Corrective Action Required
06/28/2019
no electrical service unable to inspect
Occupancy Inspection - Codes Residential Failed 7/2/2019 7/2/2019 07/02/2019
Misc
Corrective Action Required
06/28/2019
no electrical service unable to inspect
Plot Plan Inspection Passed 07/03/2019
Occupancy Inspection - Codes Residential Temporary C of O 7/3/2019 at 3:00 PM 07/03/2019
Misc
Resolved
07/03/2019
Resolved
07/26/2019
self closing devices on both garage entry doors. dryer vent in basement bath/laundry. secure water main.
Occupancy Inspection - Codes Residential Full C of O 7/26/2019 7/26/2019 at 11:30 AM 07/26/2019
Documents & Images
Date Uploaded File Type Document Name
08/01/2017 Letter Codes Residential Plan Review
08/02/2017 Letter Codes Residential Plan Review
08/31/2017 Letter Foundation Only Permit Request Letter
11/17/2017 Letter Codes Residential Plan Review
05/25/2018 Receipt Receipt for transaction: 2018-003148
05/25/2018 Letter Codes Building Permit
05/29/2018 DOC052918-001
06/13/2018 Letter Inspection Summary
06/26/2018 Letter Inspection Summary
07/20/2018 Letter Inspection Summary
07/23/2018 Letter Inspection Summary
10/24/2018 Engineer Report/Study 4801 N Raintree Parkway_Lot 36 Raintree Final_2018.10.17_SuspStoop_LSMO_Pat Cochran Concrete
10/24/2018 Engineer Report/Study 4801 N Raintree Parkway_Lot 36 Raintree Final_2018.10.17_GSlab_LSMO_Pat Cochran Concrete
01/10/2019 Letter INSPECTION SUMMARY
01/11/2019 Letter INSPECTION SUMMARY
02/05/2019 Letter INSPECTION SUMMARY
02/05/2019 Letter INSPECTION SUMMARY
02/05/2019 Letter INSPECTION SUMMARY
02/06/2019 Receipt Receipt for transaction: 2019-000395
02/06/2019 Letter Codes Building Permit
02/12/2019 Letter INSPECTION SUMMARY
04/19/2019 Engineer Report/Study Final_2019.04.11_SuspStoop_Pat Cochran
05/07/2019 Letter DE-Daily Inspection Summary
05/14/2019 Letter DE-Daily Inspection Summary
06/27/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter INSPECTION SUMMARY
07/02/2019 Letter INSPECTION SUMMARY
07/03/2019 Letter INSPECTION SUMMARY
07/03/2019 Letter Codes Temporary Certificate of Occupancy
07/26/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home