Summary
PRRES20170992
Building Permit - Residential
Certificate of Occupancy
SAB CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE WITH COVERED DECK
04/05/2017
04/11/2017
11/16/2017
Locations
Contacts
SAB CONSTRUCTION LLC, Address:PO BOX 942, Phone:(816) 524-3855  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
CROWN ELECTRICAL SERVICES, Address:1213 SE 11TH TER, Phone:(816) 272-5379  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 04/10/2017
Kim Brennan
Residential Plan Review Approved 04/07/2017 04/07/2017
Kim Brennan
Plot Plan Review Approved 04/07/2017 04/07/2017
Nick Lightner
Plot Plan Review (P&D) Approved 04/07/2017 04/05/2017
Shannon McGuire
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $949.35 $949.35 Paid 04/11/2017
Right of Way Permit Fee $75.00 $75.00 Paid 04/11/2017
8331507-Sewer Connection Fee $390.00 $390.00 Paid 04/11/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 04/11/2017
Water Meter Fee $405.36 $405.36 Paid 04/11/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/14/2017 (2:30) 4/14/2017 04/14/2017
Sewer Service Inspection - R Passed 4/25/2017 (1:15) 4/25/2017 04/25/2017
Underslab Plumbing Inspection - Residential Passed 4/28/2017 4/28/2017 04/28/2017
Erosion Control Inspection Residential Failed 4/28/2017 04/28/2017
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/28/2017
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Water Service Inspection - R Not Ready 5/9/2017 (11:00) 5/9/2017 05/09/2017
Water Service Inspection - R Partial 5/9/2017 (1:00) 5/9/2017 05/09/2017
Misc
Corrective Action Required
05/09/2017
-THE WATER SERVICE LINE FROM THE METER TO THE MAIN HAS A COUPLING NEAR THE STREET CURB, DUE TO LONG LENGTH ACROSS THE STREET. NEED APPROVAL OF PUBLIC WORKS. EVERYTHING ELSE IS OK
Water Service Inspection - R Passed 05/09/2017
Misc
Resolved
05/09/2017
-THE WATER SERVICE LINE FROM THE METER TO THE MAIN HAS A COUPLING NEAR THE STREET CURB, DUE TO LONG LENGTH ACROSS THE STREET. NEED APPROVAL OF PUBLIC WORKS. EVERYTHING ELSE IS OK
Electrical Service Inspection Passed 7/28/2017 07/28/2017
Gas Service Inspection - Residential Failed 7/28/2017 07/28/2017
Misc
Corrective Action Required
07/28/2017
low psi
All Rough Inspection - Residential Failed 7/28/2017 07/28/2017
Misc
Corrective Action Required
07/28/2017
-=firestop flue chase to attic - firestop fireplace chase to attic , 1/2" used need 3/4" -firesstop bsmt bath south side of tub at ceiling. - firestop bsmt north closets vertical to horizontal. -bond metal box front of bsmt wall -support bottom of stair stringer to landing. -provide access to gas valve unfer fireplace -plate bolts,nuts, washers garage walls. - install garage headers straps header to top plates. - nail H frame garage walls. - connect rafters to ceiling joist over dbl garage door. -provide fall in plumbing vents in attic.
Erosion Control Inspection Residential Failed 07/28/2017
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/28/2017
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Passed 8/2/2017 8/2/2017 08/02/2017
Erosion Control Inspection Residential Partial 8/2/2017 8/2/2017 08/02/2017
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/02/2017
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Gas Service Inspection - Residential Passed 8/9/2017 8/9/2017 08/09/2017
Misc
Resolved
08/09/2017
low psi
Driveway Inspection Partial 10/13/2017 10/13/2017 10/13/2017
Driveway Inspection Passed 10/18/2017 at 8:50 AM 10/18/2017
Occupancy Inspection - Codes Residential Failed 11/8/2017 11/8/2017 at 9:50 AM 11/08/2017
Misc
Corrective Action Required
11/08/2017
-OBTAIN LAWN IRRGATION PERMIT -GARAGE DOOR NOT SELF-CLOSING&LATCHING -GARAGE STAIR HANDRAIL NOT GRIPABLE -INSTALL OVEN BREAKER LOCK -BOND THE HYDROTUB WATER VALVE ASSY. -INSTALL CO ALARM OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS -INSTALL FRONT BATH LIGHT -DRAIN THE FURNACE CONDENSATE TO FLOOR DRAIN. DRAIN LINES ARE BELOW RECEPTOR LEVEL -THE TRAP, WHERE THE FURNACE CONDENSATE LINES CURRENTLY FLOW INTO, IS NOT VENTED PER CODE. CANNOT USE THE VERTICAL 2" DRAIN LINE TO VENT THE TRAP. INSTALL SEPARATE VENT OR GET RID OF IT -ALL THE NON-DEDICATED RECEPTACLE IN UNFINISHED BASEMENT MUST BE GFCI. INSTALL DUPLEX THE RECEPTACLE FOR THE SUMP PUMP AND BATTERY BACKUP OR PROVIDE GFCI PROTECTION
Occupancy Inspection - Codes Residential Temporary C of O 11/9/2017 11/9/2017 at 8:45 AM 11/09/2017
Misc
Corrective Action Required
11/08/2017
-OBTAIN LAWN IRRGATION PERMIT -EXPOSE THE SEWER TRACER BOX
Occupancy Inspection - Codes Residential Full C of O 11/16/2017 11/16/2017 at 10:35 AM 11/16/2017
Misc
Resolved
11/16/2017
-OBTAIN LAWN IRRGATION PERMIT -EXPOSE THE SEWER TRACER BOX
Documents & Images
Date Uploaded File Type Document Name
04/11/2017 Receipt Receipt for transaction: 2017-001358
04/11/2017 Letter Codes Building Permit
04/11/2017 Plot Plan DOC041117-010
04/14/2017 Letter Inspection Summary
04/25/2017 Letter Inspection Summary
04/28/2017 Letter Inspection Summary
05/09/2017 Letter Inspection Summary
05/09/2017 Letter Inspection Summary
07/28/2017 Letter Inspection Summary
08/02/2017 Letter Inspection Summary
08/09/2017 Letter Inspection Summary
11/08/2017 Letter Inspection Summary
11/09/2017 Letter Codes Temporary Certificate of Occupancy
11/16/2017 Letter Field Certificate of Occupancy
11/17/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home