Summary
PRRES20170753
Building Permit - Residential
Certificate of Occupancy
D AND D BUILDING INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT COVERED DECK
03/20/2017
04/06/2017
11/22/2017
Locations
Contacts
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
D AND D BUILDING INC, Address:PO BOX 7014, Phone:(816) 491-2125  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 03/22/2017 04/06/2017
Development Center
Plot Plan Review Approved 03/24/2017 03/29/2017
Nick Lightner
PW-Misc
Corrective Action Required
03/21/2017

Asked for them to add finshed contours to the plot plan.
DE Corps of Engineers
Corrective Action Required
03/21/2017

SE corner of the lot looked to be a foot lower then what the MDP is caling out
Plot Plan Review Rejected 03/22/2017 03/21/2017
Nick Lightner
PW-Misc
Corrective Action Required
03/21/2017

Asked for them to add finshed contours to the plot plan.
DE Corps of Engineers
Corrective Action Required
03/21/2017

SE corner of the lot looked to be a foot lower then what the MDP is caling out
Residential Plan Review Rejected 03/22/2017 03/20/2017
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $922.25 $922.25 Paid 04/06/2017
8331507-Sewer Connection Fee $450.00 $450.00 Paid 04/06/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 04/06/2017
Water Meter Fee $405.36 $405.36 Paid 04/06/2017
Right of Way Permit Fee $75.00 $75.00 Paid 04/06/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/18/2017 (10:30) 4/18/2017 04/18/2017
Underslab Plumbing Inspection - Residential Passed 5/10/2017 5/10/2017 05/10/2017
Erosion Control Inspection Residential Failed 5/10/2017 05/10/2017
Misc
Corrective Action Required
05/10/2017
-REPAIR EROSION CONTROL AT REAR OF LOT
Piers/Caissons Inspection - Residential Passed 6/12/2017 6/12/2017 06/12/2017
Gas Service Inspection - Residential Failed 6/14/2017 6/14/2017 06/14/2017
Misc
Corrective Action Required
06/14/2017
-NO GAUGE
Sewer Service Inspection - R Passed 6/16/2017 6/16/2017 06/16/2017
Water Service Inspection - R Passed 6/20/2017 (1:30) 6/20/2017 06/20/2017
Electrical Service Inspection Passed 6/26/2017 06/26/2017
Gas Service Inspection - Residential Passed 6/26/2017 06/26/2017
Misc
Resolved
06/26/2017
-NO GAUGE
All Rough Inspection - Residential Failed 6/26/2017 6/26/2017 06/26/2017
Misc
Corrective Action Required
06/26/2017
***RE-ESTABLISH EROSION CONTROL ALONG THE REAR OF THE LOT FRAMING: -NAIL WEST GARAGE PRTAL WALL SHEATHING TO SILL PLATE; ADD MORE NAILING OF H-FRAME TO HEADER -PROVIDE PLAN ON SITE; CHECK CS-PF PORTAL WALLS AT REAR -INSTALL ALL EXTERIOR DOOR FRAMES PER LS SECURITY CODE. - FIREBLOCKING: FB FLOOR AT TRAP; FB BASEMENT WALL SPACE PER CODE -BLOCK UNDER HEADER KING STUDS. HEADER BETWEEN MASTER BATH AND MASTER CLOSET -BLOCK BETWEEN LAPPED JOISTS ABOVE I BEAM NEAR STAIR BOTTOM LANDING -ANCHOR ALL BASEMENT SILL PLATE PER CODE. TIGHTEN NUTS. INSTALL MISSING WASER&NUTS -BLOCK CANTILEVERED JOISTS UNDER MASTER BED -COMPLETE FRAMING, INSTALL FIREPLACE, AND GAS CONNECTION AND FIREBLOCK AS REQUIRED ELECTRICAL: -COMPLETE WIRING TO DECK FIREPLACE TV OUTLET -PROTECT WIRING. STAPLE WIRING MINIMUM 1.25" AWAY FROM NAILING SURFACE (ABOVE WET BAR, SMOKE DETECTOR OUTSIDE BASEMENT BED, AT CEILING NEAR SERVICE PANEL, ETC) PLUMBING: -STRAP WALL TOP PLATES ABOVE COOKTOP -KITCHEN ISLAND LOOP VENT NOT DONE PROPERLY. (ALSO S TEE CANNOT BE USED FOR HOR-HOR DRAINAGE CONNECTION). JUST SEE THE DRAWING ***OK TO INSULATE
Piers/Caissons Inspection - Residential Failed 6/28/2017 (9:00) 6/28/2017 06/28/2017
Misc
Corrective Action Required
06/28/2017
-REMOVE ALL LOOSE DIRT FROM PIER HOLES
Piers/Caissons Inspection - Residential Failed 6/28/2017 (1:30) 6/28/2017 06/28/2017
Misc
Corrective Action Required
06/28/2017
-REMOVE ALL LOOSE DIRT FROM PIER HOLES **2ND REINSPECTION ON THE SAME DAY. NOTHING WAS DONE. REINSPECTION ASSESSED.
All Rough Inspection - Residential Failed 6/29/2017 6/29/2017 06/29/2017
Misc
Corrective Action Required
06/26/2017
***RE-ESTABLISH EROSION CONTROL ALONG THE REAR OF THE LOT ***29-JUNE-INSPECTION DENIED FOR FAILURE TO CORRECT THE EROSION CONTROL DEFICIENCY. SILT RUN-OFF SHALL BE CLEANED OFF FRAMING: -NAIL WEST GARAGE PRTAL WALL SHEATHING TO SILL PLATE; ADD MORE NAILING OF H-FRAME TO HEADER -PROVIDE PLAN ON SITE; CHECK CS-PF PORTAL WALLS AT REAR -INSTALL ALL EXTERIOR DOOR FRAMES PER LS SECURITY CODE. - FIREBLOCKING: FB FLOOR AT TRAP; FB BASEMENT WALL SPACE PER CODE -BLOCK UNDER HEADER KING STUDS. HEADER BETWEEN MASTER BATH AND MASTER CLOSET -BLOCK BETWEEN LAPPED JOISTS ABOVE I BEAM NEAR STAIR BOTTOM LANDING -ANCHOR ALL BASEMENT SILL PLATE PER CODE. TIGHTEN NUTS. INSTALL MISSING WASER&NUTS -BLOCK CANTILEVERED JOISTS UNDER MASTER BED -COMPLETE FRAMING, INSTALL FIREPLACE, AND GAS CONNECTION AND FIREBLOCK AS REQUIRED ELECTRICAL: -COMPLETE WIRING TO DECK FIREPLACE TV OUTLET -PROTECT WIRING. STAPLE WIRING MINIMUM 1.25" AWAY FROM NAILING SURFACE (ABOVE WET BAR, SMOKE DETECTOR OUTSIDE BASEMENT BED, AT CEILING NEAR SERVICE PANEL, ETC) PLUMBING: -STRAP WALL TOP PLATES ABOVE COOKTOP -KITCHEN ISLAND LOOP VENT NOT DONE PROPERLY. (ALSO S TEE CANNOT BE USED FOR HOR-HOR DRAINAGE CONNECTION). JUST SEE THE DRAWING ***OK TO INSULATE
All Rough Inspection - Residential Partial 7/7/2017 7/7/2017 07/06/2017
Misc
Corrective Action Required
06/29/2017
-INSTALL ALL EXTERIOR DOOR FRAMES PER LS SECURITY CODE. **NOT DONE AT THIS TIME. MAKE SURE THAT ANY GAP BETWEEN THE DOOR FRAME AND STUD AT HINGES AND STRIKE PLATE SIDE IS FILLED WITH SOLID WOOD PER LS SECURITY CODE -COMPLETE FRAMING, INSTALL FIREPLACE, AND GAS CONNECTION AND FIREBLOCK AS REQUIRED **FB THE FIREPLACE SPACE FROM FURDOWN&JOIST SPACE ***OK TO INSULATE
All Rough Inspection - Residential Failed 7/10/2017 7/10/2017 07/10/2017
Misc
Corrective Action Required
07/06/2017
-FIREBLOCK THE BASEMENT FIREPLACE SPACE FROM FURDOWN&JOIST SPACE ***OK TO INSULATE
All Rough Inspection - Residential Passed 7/13/2017 7/13/2017 07/12/2017
Misc
Resolved
07/12/2017
-FIREBLOCK THE BASEMENT FIREPLACE SPACE FROM FURDOWN&JOIST SPACE ***OK TO INSULATE
Driveway Inspection Partial 11/7/2017 11/7/2017 at 6:48 AM 11/07/2017
Erosion Control Inspection Residential Passed 11/20/2017
Misc
Resolved
11/20/2017
-REPAIR EROSION CONTROL AT REAR OF LOT
Piers/Caissons Inspection - Residential Passed 11/20/2017
Misc
Resolved
11/20/2017
-REMOVE ALL LOOSE DIRT FROM PIER HOLES **2ND REINSPECTION ON THE SAME DAY. NOTHING WAS DONE. REINSPECTION ASSESSED.
Driveway Inspection Passed 11/9/2017 11/20/2017
Occupancy Inspection - Codes Residential Failed 11/20/2017 11/20/2017 at 9:15 AM 11/20/2017
Misc
Corrective Action Required
11/20/2017
-SEAL ABOVE AC DISCONNECT, HOSE BIBB, METER BOX, ETC -RETURN DECK HANDRAIL TO NEWEL POSTS -PROVIDE FALL PROTECTION PER CODE AT REAR DINING AND MASTER BED RM WINDOWS -STAIR TREADS AND LANDINGS ILLUMINATION NOT COMPLIANT. SEE IRC R303.7 -RECEPTACLE WITHIN SIX FT OF THE WET BAR SINK MUST BE GFCI-PROTECTED -INSTALL BREAKER LOCK FOR OUT-OF-SIGHT WATER HEATER -INSTALL MAXIMUM 40 AMP BREAKER FOR THE AC UNIT
Occupancy Inspection - Codes Residential Temporary C of O 11/21/2017 at 10:50 AM 11/21/2017
Misc
Corrective Action Required
11/20/2017
-STAIR TREADS AND LANDINGS ILLUMINATION NOT COMPLIANT. SEE IRC R303.7
Occupancy Inspection - Codes Residential Full C of O 11/22/2017 11/22/2017 at 10:45 AM 11/22/2017
Misc
Resolved
11/22/2017
-STAIR TREADS AND LANDINGS ILLUMINATION NOT COMPLIANT. SEE IRC R303.7
Documents & Images
Date Uploaded File Type Document Name
04/06/2017 Receipt Receipt for transaction: 2017-001272
04/06/2017 Letter Codes Building Permit
04/06/2017 Plot Plan DOC040617-007
04/18/2017 Letter Inspection Summary
05/10/2017 Letter Inspection Summary
06/12/2017 Letter Inspection Summary
06/14/2017 Letter Inspection Summary
06/16/2017 Letter Inspection Summary
06/20/2017 Letter Inspection Summary
06/26/2017 Letter Inspection Summary
06/28/2017 Letter Inspection Summary
06/28/2017 Letter Re-Inspection Fee
06/28/2017 Letter Inspection Summary
06/29/2017 Letter Inspection Summary
07/06/2017 Letter Inspection Summary
07/10/2017 Letter Inspection Summary
07/12/2017 Letter Inspection Summary
11/20/2017 Letter Inspection Summary
11/21/2017 Letter Codes Temporary Certificate of Occupancy
11/22/2017 Letter Field Certificate of Occupancy
11/29/2017 Letter Codes Final Certificate of Occupancy
12/18/2017 inspection report 20170753
12/18/2017 inspection report 20170753
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home