Permit Application Status

PRRES20170161


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20170161
Building Permit - Residential
Certificate of Occupancy
TRAILS OF PARK RIDGE LLC
NEW SINGLE FAMILY
NEW HOUSE WITH COVERED DECK
01/26/2017
02/01/2017
09/18/2017
Locations
Contacts
TRAILS OF PARK RIDGE LLC, Address:3170 NE CARNEGIE DR STE 400  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 01/30/2017 02/01/2017
Kim Brennan
Plot Plan Review Approved 01/30/2017 02/01/2017
Kim Brennan
Plot Plan Review (P&D) Approved 01/30/2017 01/26/2017
Christina Stanton
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $905.31 $905.31 Paid 02/01/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 02/01/2017
8331507-Sewer Connection Fee $390.00 $390.00 Paid 02/01/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 02/01/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 02/01/2017
9110078-Valuation Fee New Single Family $63.93 $63.93 Paid 05/18/2017
$969.24
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/16/2017 (1:30) 2/16/2017 02/16/2017
Underslab Plumbing Inspection - Residential Passed 3/16/2017 3/16/2017 03/16/2017
Sewer Service Inspection - R Passed 4/20/2017 (11:30) 4/20/2017 04/20/2017
Water Service Inspection - R Passed 4/25/2017 (10:45) 4/25/2017 04/25/2017
Electrical Service Inspection Passed 5/19/2017 5/19/2017 05/19/2017
Gas Service Inspection - Residential Passed 5/19/2017 5/19/2017 05/19/2017
All Rough Inspection - Residential Failed 5/19/2017 5/19/2017 05/19/2017
Misc
Corrective Action Required
05/19/2017
***REPAIR EROSION CONTROL AT FRONT FRAMING: -NAIL SIDING TO SILL PLATE PER CODE -NAIL CORNER STUDS W/ 16D @ 12" OC OR EQUIVALENT NAILING -SEAL RETURN AIR SPACE AT FOYER WALL -ANCHOR GARAGE SILL PLATES PER CODE. MIN 2 ANCHORS FOR THE SHORT PLATE. TIGHTEN ALL ANCHOR NUTS -INSTALL STRAPS FOR THE GARAGE PORTAL BRACE WALL -BRACE LVL BEAM ENDS FROM ROTATION -FIREBLOCK FIREPLACE SPACE FROM ATTIC; FB BASEMENT WALL SPACE FROM CEILING FURDOWN SPACE -PROVIDE SOLID BLOCKING UNDER POINT LOAD BELOW PANTRY WALL -INSTALL STUD W/ GREEN PLATE AT BASEMENT BED WALL; OR IF DOOR WILL BE INSTALLED, THEN COMPLETE RELOCATE WIRING -NOTCHED JOIST BELOW FRONT BAT TOILET ELECTRICAL: -PAN OFF ELECTRICAL FROM RETURN AIR SPACE INSIDE OFFICE WALL -PROTECT WIRING RUNNING ACROSS CEILING JOIST WITHIN 6 FT OF ATTIC ACCESS -IN BASEMENT, PROTECT WIRING RUNNING ACROSS BOTTOM OF JOISTS; OR MOVE THE WIRINGSS TO WALL/DUCT MECHANICAL: -PROVIDE MIN. 1" AIR GAP AROUND THE FIREPLACE VENT ****DO NOT INSULATE
Piers/Caissons Inspection - Residential Passed 5/22/2017 (2:00) 5/22/2017 05/22/2017
All Rough Inspection - Residential Failed 5/24/2017 5/24/2017 05/24/2017
Misc
Corrective Action Required
05/19/2017
-INSTALL STRAPS FOR THE GARAGE PORTAL BRACE WALLS **I MEAN STRAP THE INNER SIDES OF THE PORTAL BRACE WALLS OR JUST PUT SOME MORE NAILING OF THE H-FRAMES INTO THE LVL HEADER -FIREBLOCK FIREPLACE SPACE FROM ATTIC; FB BASEMENT WALL SPACE FROM CEILING FURDOWN SPACE **AT FIREPLACE, FB OPENINGS AT FRONT CORNERS OF FIREPLACE SPACE. FB GAPS ALONG THE TOP OF THE FIREPLACE SPACE **IN BASEMENT, FB NOT DONE ****OK TO INSULATE
All Rough Inspection - Residential Passed 5/26/2017 5/26/2017 05/26/2017
Misc
Resolved
05/26/2017
-INSTALL STRAPS FOR THE GARAGE PORTAL BRACE WALLS **I MEAN STRAP THE INNER SIDES OF THE PORTAL BRACE WALLS OR JUST PUT SOME MORE NAILING OF THE H-FRAMES INTO THE LVL HEADER -FIREBLOCK FIREPLACE SPACE FROM ATTIC; FB BASEMENT WALL SPACE FROM CEILING FURDOWN SPACE **AT FIREPLACE, FB OPENINGS AT FRONT CORNERS OF FIREPLACE SPACE. FB GAPS ALONG THE TOP OF THE FIREPLACE SPACE **IN BASEMENT, FB NOT DONE ****OK TO INSULATE
Driveway Inspection Passed 7/10/2017 7/10/2017 07/10/2017
Sidewalk Inspection Passed 7/10/2017 07/10/2017
Occupancy Inspection - Codes Residential Temporary C of O 8/7/2017 8/7/2017 08/07/2017
Misc
Corrective Action Required
08/09/2017
-HAVE THE LAWN IRRIGATION SUB SEND BACKFLOW TEST REPORT TO WATER DEPARTMENT -BRING THE WATER METER TO FINAL GRADE -FINAL GRADE, SOD, SPLASHBLOCKS -SEAL EXTERIOR WALL PENETRATIONS -PROVIDE STAIR ILLUMINATION PER CODE -INSTALL KITCHEN HOOD
Occupancy Inspection - Codes Residential Temporary C of O 8/9/2017 8/9/2017 08/09/2017
Misc
Corrective Action Required
08/09/2017
-BRING THE WATER METER TO FINAL GRADE MAKE SURE THAT THE METER TOP-LID DISTANCE IS 14"-18" -FINAL GRADE, SOD, SPLASHBLOCKS
Occupancy Inspection - Codes Residential Full C of O 9/18/2017 9/18/2017 09/18/2017
Misc
Resolved
09/18/2017
-BRING THE WATER METER TO FINAL GRADE MAKE SURE THAT THE METER TOP-LID DISTANCE IS 14"-18" -FINAL GRADE, SOD, SPLASHBLOCKS
Documents & Images
Date Uploaded File Type Document Name
02/01/2017 Receipt Receipt for transaction: 2017-000313
02/01/2017 Letter Codes Building Permit
02/01/2017 Plot Plan DOC020117-007
02/16/2017 Letter Inspection Summary
03/16/2017 Letter Inspection Summary
04/20/2017 Letter Inspection Summary
04/25/2017 Letter Inspection Summary
05/18/2017 Receipt Receipt for transaction: 2017-002652
05/18/2017 Letter Codes Building Permit
05/19/2017 Letter Inspection Summary
05/22/2017 Letter Inspection Summary
05/24/2017 Letter Inspection Summary
05/26/2017 Letter Inspection Summary
07/10/2017 Letter Inspection Summary
08/07/2017 Letter Codes Temporary Certificate of Occupancy
08/09/2017 Letter Codes Temporary Certificate of Occupancy
09/18/2017 Letter Field Certificate of Occupancy
09/19/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home