Permit Application Status

PRRES20170104


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20170104
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK
01/17/2017
02/10/2017
02/21/2018
Locations
Contacts
SCOTT PRIER HOMES LLC, Address:404 SE HACKAMORE DR, Phone:(816) 509-8302  
HOLSEY ELECTRIC, Address:1637 NW 100 RD, Phone:(816) 697-2112  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
SUBURBAN PLUMBING, Address:20124 HOPS CREEK DR, Phone:(816) 985-0259  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/19/2017 01/20/2017
Jonathon Smith
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $771.97 $771.97 Paid 02/10/2017
8331507-Sewer Connection Fee $390.00 $390.00 Paid 02/10/2017
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 02/10/2017
8350015-Water Meter Fee $405.36 $405.36 Paid 02/10/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 02/10/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/13/2017 (11:00) 2/13/2017 02/13/2017
Erosion Control Inspection Residential Failed 3/2/2017 03/02/2017
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/02/2017
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 3/2/2017 3/2/2017 03/02/2017
Sewer Service Inspection - R Passed 4/24/2017 (11:00) 4/24/2017 04/24/2017
Water Service Inspection - R Passed 4/25/2017 04/25/2017
Gas Service Inspection - Residential Passed 5/9/2017 05/09/2017
Electrical Service Inspection Passed 5/9/2017 05/09/2017
All Rough Inspection - Residential Failed 5/9/2017 5/9/2017 05/09/2017
Misc
Corrective Action Required
05/09/2017
****INSTALL EROSION CONTROL ALONG THE WHOLE BACK SIDE OF THE LOT. REPAIR ALL DAMAGED EROSION CONTROL. SILT FENCE BOTTOM SHALL BE BURIED MIN. 6" BELOW GRADE FRAMING: -GARAGE PROTAL WALLS-FOUNDATION STRAPS NOT INSTALLED. INSTALL 2" WASHER FOR THE ANCHOR BOLTS. MIN. 2 ANCHORS FOR THE SILL PLATE -SUPPORT THE HIPS ABOVE FRONT BED; STRUT CANNOT BE MORE THAN 45 DEGREES FROM VERTICAL; INSTALL RAFTER TIES EVERY 4 FT MIN. -INSTALL COLLAR TIES EVERY FOUR FT ABOVE LIVING RM -FIREBLOCKING: FB WALL AT THERMOSTAT; FB DOUBLE STUD WALL IN MASTER BATH -INSTALL R-30 INSULATION ABOVE MASTER BATH -SECURE MASTER BATH BATH FAN DUCT ABOVE INSULATION LEVEL -DOUBLE THE CEILING TRIMMER JOIST THAT BEARS ON THE TWO CAR GARAGE HEADER -NAIL ONE HANGER NEAR THE DECK DOOR ELECTRICAL: -PROTECT NM WIRING WITHIN SIX FT OF ATTIC ACCESS. ALL THE CABLES THAT RUN ACROSS THE STUDDINGS AND JOIST SHALL BE PROTECTED ****OK TO INSLATE
All Rough Inspection - Residential Failed 5/12/2017 05/12/2017
Misc
Corrective Action Required
05/09/2017
FRAMING: -SUPPORT THE HIPS ABOVE FRONT BED; INSTALL RAFTER TIES EVERY 4 FT MIN. **SUPPORT THE HIPS WITH A FRAME. GIVE PLENTY OF NAILS AT RAFTER TIE-RAFTER CONNECTIONS. LOOK AT TABLE IRC R802.5.1(9) FOR REFERENCE **DON'T CONFUSE THE COLLAR TIES FROM RAFTER TIES. RAFTER TIES ARE WITHIN BOTTOM 1/3 OF RAFTER HEIGHT; COLLAR TIES ARE WITHIN 1/3 UPPER TOP OF RAFTERS ELECTRICAL: -PROTECT NM WIRING WITHIN SIX FT OF ATTIC ACCESS. ALL THE CABLES THAT RUN ACROSS THE STUDDINGS SHALL BE PROTECTED **PROTECT SIX FT OUT FROM ATTIC ACCESS ****OK TO INSULATE
All Rough Inspection - Residential Passed 5/16/2017 5/16/2017 05/16/2017
Misc
Resolved
05/16/2017
FRAMING: -SUPPORT THE HIPS ABOVE FRONT BED; INSTALL RAFTER TIES EVERY 4 FT MIN. **SUPPORT THE HIPS WITH A FRAME. GIVE PLENTY OF NAILS AT RAFTER TIE-RAFTER CONNECTIONS. LOOK AT TABLE IRC R802.5.1(9) FOR REFERENCE **DON'T CONFUSE THE COLLAR TIES FROM RAFTER TIES. RAFTER TIES ARE WITHIN BOTTOM 1/3 OF RAFTER HEIGHT; COLLAR TIES ARE WITHIN 1/3 UPPER TOP OF RAFTERS ELECTRICAL: -PROTECT NM WIRING WITHIN SIX FT OF ATTIC ACCESS. ALL THE CABLES THAT RUN ACROSS THE STUDDINGS SHALL BE PROTECTED **PROTECT SIX FT OUT FROM ATTIC ACCESS ****OK TO INSULATE
Piers/Caissons Inspection - Residential Passed 6/12/2017 (8:00) 6/12/2017 06/12/2017
Driveway Inspection Passed 8/11/2017 8/11/2017 08/11/2017
Erosion Control Inspection Residential Passed 02/14/2018
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/14/2018
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 2/14/2018 2/14/2018 at 8:00 AM 02/14/2018
Misc
Corrective Action Required
02/14/2018
-HAVE THE LAWN IRRIGATION CONTRACTOR TO SUBMIT TO CITY THE BACKFLOW TEST REPORT -KCPL TRANSFORMER IS DISPLACED -PROVIDE MIN SIX INCHES FROM WINDOW SIDING TO GRADE -VERIFY THAT THE DECK POSTS ARE ANCHORED TO THE PIERS -LOOP DISH WASHER DRAIN TO NEAR THE TOP OF CABINET AND SECURE IN PLACE -PEX WATER LINES ABOVE WATER HEATER MUST HAVE MIN. SIX INCHES OF CLEARANCE FROM VENT. INSTALL COPPER TUBINGS FROM WATER HEATER TO CLEAR THE VENT MIN. SIX INCHES, THEN CONNECT THE PEX LINES
Occupancy Inspection - Codes Residential Full C of O 2/21/2018 2/21/2018 at 10:45 AM 02/21/2018
Misc
Resolved
02/21/2018
-KCPL TRANSFORMER IS DISPLACED -PROVIDE MIN SIX INCHES FROM WINDOW SIDING TO GRADE -VERIFY THAT THE DECK POSTS ARE ANCHORED TO THE PIERS -LOOP DISH WASHER DRAIN TO NEAR THE TOP OF CABINET AND SECURE IN PLACE -PEX WATER LINES ABOVE WATER HEATER MUST HAVE MIN. SIX INCHES OF CLEARANCE FROM VENT. INSTALL COPPER TUBINGS FROM WATER HEATER TO CLEAR THE VENT MIN. SIX INCHES, THEN CONNECT THE PEX LINES
Documents & Images
Date Uploaded File Type Document Name
02/10/2017 Receipt Receipt for transaction: 2017-000419
02/10/2017 Letter Codes Building Permit
02/10/2017 Plot Plan DOC021017-011
02/13/2017 Letter Inspection Summary
03/02/2017 Letter Inspection Summary
04/24/2017 Letter Inspection Summary
04/25/2017 Letter Inspection Summary
05/09/2017 Letter Inspection Summary
05/12/2017 Letter Inspection Summary
05/16/2017 Letter Inspection Summary
06/12/2017 Letter Inspection Summary
08/11/2017 Letter Inspection Summary
02/14/2018 Letter Inspection Summary
02/21/2018 Letter Field Certificate of Occupancy
02/22/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home