Summary
PRRES20163237
Building Permit - Residential
Certificate of Occupancy
MCGRAW HOMES INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY HOME COVERED DECK FINISHED BASEMENT
12/20/2016
01/12/2017
09/25/2017
Locations
Contacts
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
INTREPID ELECTRIC LLC, Address:620 S KISNER CIR, Phone:(816) 796-2781  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/22/2016 12/21/2016
Jonathon Smith
Plot Plan Review (P&D) Approved 12/22/2016 12/21/2016
Christina Stanton
Residential Plan Review Rejected 12/22/2016 12/21/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $933.54 $933.54 Paid 01/12/2017
8331507-Sewer Connection Fee $420.00 $420.00 Paid 01/12/2017
Water Tap Fee $3,310.00 $3,310.00 Paid 01/12/2017
Water Meter Fee $405.36 $405.36 Paid 01/12/2017
Right of Way Permit Fee $75.00 $75.00 Paid 01/12/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/18/2017 (2:45) 1/18/2017 01/18/2017
Foundation Inspection - Residential Passed 1/31/2017 (3:00) 1/31/2017 01/31/2017
Sewer Service Inspection - R Failed 2/15/2017 02/15/2017
Misc
Corrective Action Required
02/15/2017
SEWER TRENCH/HOLE RIGHT NEXT TO THE FOUNDATION. FILL IN HOLE WITH AB3 TO FOOTING LEVEL
Sewer Service Inspection - R Passed 2/15/2017 02/15/2017
Misc
Corrective Action Required
02/15/2017
SEWER TRENCH/HOLE RIGHT NEXT TO THE FOUNDATION. FILL IN HOLE WITH AB3 TO FOOTING LEVEL
Water Service Inspection - R Partial 2/17/2017 (8:00) 2/17/2017 02/17/2017
Water Service Inspection - R Passed 2/17/2017 (2:00) 2/17/2017 02/17/2017
Underslab Plumbing Inspection - Residential Failed 2/23/2017 2/23/2017 02/23/2017
Misc
Corrective Action Required
02/23/2017
**INSTALL EROSION CONTROL TO PROTECT THE FLOOD BASIN -CANNOT CUT SQUARE HOLE AND INSERT DRAIN TILE TO SUMP PIT -CONNECT THE DRAIN TILE WITH PROPER CONNECTOR -PERFORATED FOUNDATION DRAIN TILES MUST BE SLEEVED WITH FILTER MEMBRANE OR THE FILTER MEMBRANE SHALL COVER THE GRAVEL COVERING THE DRAIN
Underslab Plumbing Inspection - Residential Passed 2/24/2017 2/24/2017 02/24/2017
Misc
Resolved
02/24/2017
**INSTALL EROSION CONTROL TO PROTECT THE FLOOD BASIN -CANNOT CUT SQUARE HOLE AND INSERT DRAIN TILE TO SUMP PIT -CONNECT THE DRAIN TILE WITH PROPER CONNECTOR -PERFORATED FOUNDATION DRAIN TILES MUST BE SLEEVED WITH FILTER MEMBRANE OR THE FILTER MEMBRANE SHALL COVER THE GRAVEL COVERING THE DRAIN
Suspended Slab Inspection Passed 3/3/2017 (1:00) 3/3/2017 03/03/2017
Piers/Caissons Inspection - Residential Failed 3/22/2017 3/22/2017 03/22/2017
Misc
Corrective Action Required
03/22/2017
-ONLY ONE PIER IS DRILLED
Piers/Caissons Inspection - Residential Passed 3/23/2017 03/23/2017
Misc
Resolved
03/23/2017
-ONLY ONE PIER IS DRILLED
Gas Service Inspection - Residential Failed 5/10/2017 05/10/2017
Misc
Corrective Action Required
05/10/2017
-PROVIDE MIN 10 PSI PRESSURE FOR TESTING
Electrical Service Inspection Passed 5/10/2017 05/10/2017
All Rough Inspection - Residential Failed 5/10/2017 5/10/2017 05/10/2017
Misc
Corrective Action Required
05/10/2017
**REPAIR EROSION CONTROL AT REAR FRAMING: -NAIL GARAGE EXTERIOR WALL SIDING TO SILL PER CODE -ANCHOR SILL PLATES WITHIN 12" OF BREAKS THROUGHOUT -INSTALL COLLAR TIES @ 4FT INTERVAL ABOVE GARAGE -THE FOYER WALL IS NOT DESIGNATED AS A BEARING WALL. DOUBLE JOIST UNDERNEATH BUT WALL CARRIES QUITE A BIT OF ROOF LOAD. HAVE ENGINEER ADDRESS THIS -INSTALL STEEL COLUMNS FOR POINT LOAD SUPPORT PER PLAN -BRACE LVL BEAM ENDS FROM ROTRATION -OVERNOTCHED LVL AND DOUBLE CEILING JOIST AT I BEAM BEARING. NO MORE THAN 1/4 DEPTH -SUPPORT CEILING JOIST ABOVE FIREPLACE NEAR SLIDE DOOR -OVERNOTCHED VALLEY RAFTER NEAR SLIDE DOOR -NAIL LVL HANGER ABOVE TOP STAIR LANDING -PROVIDE FULL COLUMN SUPPORT FOR I BEAMS AT BOTTOM OF STAIR -FIREBLOCKING: FB FIREPLACE SPACE; FB WALL AT THERMOSTAT; FB BASEMENT WALL SPACE AND SPACE BY BASEMENT BATH SHOWER FROM FURDOWN CEILING SPACE ELECTRICAL: -INSTALL EXTERIOR LIGHTS OUTSIDE DOORS -PROVIDE RECEPTACLE WALL SPACING PER CODE FOR BEDROOM NEAR MUD -PROTCT WIRING AT OVEN AND AT LAUNRY DRYER CIRCUIT -COMPLETE WIRING MAKEUP INSIDE BOX MECHANICAL: -INSTALL SHIELD FOR FIREPLACE FLUE IN ATTIC -MOUNT SUPPLY AIR OUTLET ABOVE BASEMENT BATH PLUMBING: -OVERBORED STUDS AT BASEMENT LAUNDRY ***OK TO INSULATE
Piers/Caissons Inspection - Residential Passed 5/12/2017 5/12/2017 05/12/2017
All Rough Inspection - Residential Failed 5/18/2017 5/18/2017 05/18/2017
Misc
Corrective Action Required
05/10/2017
-NAIL GARAGE EXTERIOR WALL SIDING TO SILL PER CODE -ANCHOR SILL PLATES WITHIN 12" OF BREAKS THROUGHOUT -BRACE LVL BEAM ENDS FROM ROTRATION -FIREBLOCKING: FB FIREPLACE SPACE; FB WALL AT THERMOSTAT; FB BASEMENT WALL SPACE AND SPACE BY BASEMENT BATH SHOWER FROM FURDOWN CEILING SPACE ***OK TO INSULATE
Gas Service Inspection - Residential Passed 5/18/2017 05/18/2017
Misc
Resolved
05/18/2017
-PROVIDE MIN 10 PSI PRESSURE FOR TESTING
All Rough Inspection - Residential Passed 5/19/2017 5/19/2017 05/18/2017
Misc
Resolved
05/18/2017
-NAIL GARAGE EXTERIOR WALL SIDING TO SILL PER CODE -ANCHOR SILL PLATES WITHIN 12" OF BREAKS THROUGHOUT -BRACE LVL BEAM ENDS FROM ROTRATION -FIREBLOCKING: FB FIREPLACE SPACE; FB WALL AT THERMOSTAT; FB BASEMENT WALL SPACE AND SPACE BY BASEMENT BATH SHOWER FROM FURDOWN CEILING SPACE ***OK TO INSULATE
Driveway Inspection Passed 6/21/2017 06/21/2017
Erosion Control Inspection Residential Partial 8/1/2017 08/01/2017
Misc
Corrective Action Required
08/01/2017
Clean street and establish temporary erosion control until sod is installed.
Occupancy Inspection - Codes Residential Failed 8/1/2017 8/1/2017 08/01/2017
Misc
Corrective Action Required
08/01/2017
1. Final grade, downspouts, splashblocks, sod, etc. 2. Seal exterior penetrations. 3. Secure guardrail post at northwest side of deck. 4. Deck stair needs graspable handrail. 5. Missing joist hangers and nails in existing joist hangers at deck. 6. Deck cannot be anchored to cantelever (unless specifically designed for such). 7. Cedar deck post cannot be in contact with grade. 8. Secure elec. recept. yokes throughout. 9. Lock-out/Tag-out bracket needed in breaker panel for over-range hood circuit. 10. Need 2nd lock on sliding doors at master bedroom and downstairs. 11. Main-floor laundry receptacle needs to be GFI protected (within 6' of sink).
Occupancy Inspection - Codes Residential Temporary C of O 8/24/2017 8/24/2017 08/24/2017
Misc
Corrective Action Required
08/01/2017
1. splashblocks, sod, etc. 2. Seal exterior penetrations. 3. Secure guardrail post at northwest side of deck.
Erosion Control Inspection Residential Passed 09/25/2017
Misc
Resolved
09/25/2017
Clean street and establish temporary erosion control until sod is installed.
Occupancy Inspection - Codes Residential Full C of O 09/25/2017
Misc
Resolved
09/25/2017
1. splashblocks, sod, etc. 2. Seal exterior penetrations. 3. Secure guardrail post at northwest side of deck.
Documents & Images
Date Uploaded File Type Document Name
01/12/2017 Receipt Receipt for transaction: 2017-000127
01/12/2017 Letter Codes Building Permit
01/12/2017 Plot Plan DOC011217-001
01/18/2017 Letter Inspection Summary
01/31/2017 Letter Inspection Summary
02/15/2017 Letter Inspection Summary
02/15/2017 Letter Inspection Summary
02/17/2017 Letter Inspection Summary
02/17/2017 Letter Inspection Summary
02/23/2017 Letter Inspection Summary
02/24/2017 Letter Inspection Summary
03/03/2017 Letter Inspection Summary
03/22/2017 Letter Inspection Summary
03/23/2017 Letter Inspection Summary
05/10/2017 Letter Inspection Summary
05/12/2017 Letter Inspection Summary
05/18/2017 Letter Inspection Summary
05/18/2017 Engineer Report/Study Lot 11 Monticello 1340 NE Brandywine
05/18/2017 Letter Inspection Summary
06/21/2017 Letter Inspection Summary
08/01/2017 Letter Inspection Summary
08/24/2017 Letter Codes Temporary Certificate of Occupancy
09/11/2017 Engineer Report/Study McGraw Deck 1340 NE Brandywine Rd LSMO 8-7-17-17
09/25/2017 Letter Field Certificate of Occupancy
09/26/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home