Summary
PRRES20163030
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK
11/21/2016
11/29/2016
09/06/2017
Locations
Contacts
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
DAVE'S ELECTRIC, Address:1601 SW JEFFERSON ST, Phone:(816) 525-0409  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/23/2016 11/22/2016
Jonathon Smith
Plot Plan Review (P&D) Approved 11/23/2016 11/21/2016
Christina Stanton
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $825.71 $825.71 Paid 11/29/2016
8331507-Sewer Connection Fee $450.00 $450.00 Paid 11/29/2016
8331401-Water Tap Fee $3,310.00 $3,310.00 Paid 11/29/2016
8350015-Water Meter Fee $405.36 $405.36 Paid 11/29/2016
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 11/29/2016
9110078-Valuation Fee New Single Family $42.91 $42.91 Paid 03/03/2017
$868.62
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/30/2016 (1:30) 11/30/2016 11/30/2016
Underslab Plumbing Inspection - Residential Passed 12/15/2016 12/15/2016 12/14/2016
Piers/Caissons Inspection - Residential Failed 1/13/2017 (10:15) 1/13/2017 01/13/2017
Misc
Corrective Action Required
01/13/2017
REMOVE ALL LOOSE DIRT AND DEBRIS FROM PIER HOLES
Sewer Service Inspection - R Passed 1/26/2017 (1:00) 1/26/2017 01/26/2017
Piers/Caissons Inspection - Residential Passed 1/27/2017 (1:30) 1/27/2017 01/27/2017
Misc
Corrective Action Required
01/13/2017
REMOVE ALL LOOSE DIRT AND DEBRIS FROM PIER HOLES
Water Service Inspection - R Partial 1/31/2017 (8:00) 1/31/2017 01/31/2017
Water Service Inspection - R Passed 2/2/2017 2/2/2017 02/02/2017
All Rough Inspection - Residential Failed 3/8/2017 3/8/2017 03/08/2017
Misc
Corrective Action Required
03/07/2017
FRAMING: -BLOCK DECK DOOR STUDS PER SECURITY CODE -COMPLETE FRAMING AT FIREPLACE AND FASTEN FIREPLACE TO FRAMING -BRACE LVL END FROM ROTATION ABOVE STAIR -TRIPLE JOIST NEAR FIREPLACE-INSTALL FULL STUD SUPPORT AND INSTALL HANGER AT BEAM CONNECTION -ANCHOR SHORT SILL PLATE AT MID-STAIR LANDING ELECTRICAL: -INSTALL REAR RECEPTACLE ACCESSIBLE FROM AND WITHIN 6.5 FT OF GRADE -COMPLETE ELECTRICAL TO ATTIC LIGHT -BOX NEAR COOKTOP-INSTALL PROPER 3-GANG BOX TO FASTEN TO STUD OR FASTEN BOX TO STUD WITHIN 1/4" OF BACKSIDE OF BOX -WALL RECEPTACLE SPACING REQUIREMENT AT REAR LIVING RM WALL -PROTECT WIRING INSIDE FOYER CLOSET -ELECTRICAL INSIDE RETURN AIR SPACE ABOVE BASEMENT BED&HALLWAY -PROTECT WIRINGS: WIRING WITHIN 6.5 FT OF ATTIC ACCESS; WIRING JUMPING FROM PANEL TO FLOOR JOISTS MUST BE PROTECTED. CODE REQUIRES NM CABLES TO CLOSELY FOLLOW THE SURFACE OF THE BUILDING STRUCTURE; WIRINGS RUNNING ACROSS BOTTOM OF JOISTS-EITHER INSTALL RUNNING BOARD OR MOVE THEM CLOSER TO DUCT OR COVER UP; FROM NOW ON, CIRCUIT RUNNING ALONG THE FOUNDATION WALL (LIGHT CIRCUIT UNDER STOOP) MUST BE PROTECTED INSIDE A RACEWAY PLUMBING: -PROTECT WATER LINES AT LAUNDRY ***OK TO INSULATE
Electrical Service Inspection Failed 3/8/2017 3/8/2017 03/08/2017
Misc
Corrective Action Required
03/07/2017
-BOND THE SERVICE PANEL ENCLOSURE
Gas Service Inspection - Residential Passed 3/8/2017 3/8/2017 03/08/2017
All Rough Inspection - Residential Passed 3/15/2017 3/15/2017 03/15/2017
Misc
Resolved
03/15/2017
FRAMING: -BLOCK DECK DOOR STUDS PER SECURITY CODE -COMPLETE FRAMING AT FIREPLACE AND FASTEN FIREPLACE TO FRAMING -BRACE LVL END FROM ROTATION ABOVE STAIR -TRIPLE JOIST NEAR FIREPLACE-INSTALL FULL STUD SUPPORT AND INSTALL HANGER AT BEAM CONNECTION -ANCHOR SHORT SILL PLATE AT MID-STAIR LANDING ELECTRICAL: -INSTALL REAR RECEPTACLE ACCESSIBLE FROM AND WITHIN 6.5 FT OF GRADE -COMPLETE ELECTRICAL TO ATTIC LIGHT -BOX NEAR COOKTOP-INSTALL PROPER 3-GANG BOX TO FASTEN TO STUD OR FASTEN BOX TO STUD WITHIN 1/4" OF BACKSIDE OF BOX -WALL RECEPTACLE SPACING REQUIREMENT AT REAR LIVING RM WALL -PROTECT WIRING INSIDE FOYER CLOSET -ELECTRICAL INSIDE RETURN AIR SPACE ABOVE BASEMENT BED&HALLWAY -PROTECT WIRINGS: WIRING WITHIN 6.5 FT OF ATTIC ACCESS; WIRING JUMPING FROM PANEL TO FLOOR JOISTS MUST BE PROTECTED. CODE REQUIRES NM CABLES TO CLOSELY FOLLOW THE SURFACE OF THE BUILDING STRUCTURE; WIRINGS RUNNING ACROSS BOTTOM OF JOISTS-EITHER INSTALL RUNNING BOARD OR MOVE THEM CLOSER TO DUCT OR COVER UP; FROM NOW ON, CIRCUIT RUNNING ALONG THE FOUNDATION WALL (LIGHT CIRCUIT UNDER STOOP) MUST BE PROTECTED INSIDE A RACEWAY PLUMBING: -PROTECT WATER LINES AT LAUNDRY ***OK TO INSULATE
Electrical Service Inspection Passed 3/15/2017 03/15/2017
Misc
Resolved
03/15/2017
-BOND THE SERVICE PANEL ENCLOSURE
Driveway Inspection Passed 6/6/2017 6/6/2017 06/07/2017
Sidewalk Inspection Passed 6/7/2017 6/7/2017 06/07/2017
Occupancy Inspection - Codes Residential Temporary C of O 7/6/2017 07/06/2017
Misc
Corrective Action Required
07/06/2017
-OBTAIN LAWN IRRIGATION PERMIT -PERMIT DOES NOT SHOW FINISHED BASEMENT -FINAL GRADE, SOD, SPLASHBLOCKS -LOWER WATER METER TO FINAL GRADE. MAKE SURE THAT THE DISTANCE FROM TOP OF METER TO LID IS 14"-18" -SECURE AC WHIP WITHIN 12" OF DISCONNECT -COMPLETE DECK; NAIL ONE JOIST HANGER NEAR MIDDLE POST; INSTALL HANGERS UNDER TOP STAIR LANDING -INSTALL SECURITY STRIKE PLATE FOR DECK DOOR -INSTALL ANTI-BACKFLOW DEVICE FOR BASEMENT HOSE BIBB -INSTALL FACE PLATE FOR SUMP PUMP RECEPTACLE
Occupancy Inspection - Codes Residential Temporary C of O 7/14/2017 7/14/2017 07/14/2017
Misc
Corrective Action Required
07/06/2017
-FINAL GRADE, SOD, ROOF DRAINAGE SYSTEM&SPLASHBLOCKS -ADDRESS
Occupancy Inspection - Codes Residential Full C of O 09/06/2017
Misc
Resolved
09/06/2017
-FINAL GRADE, SOD, ROOF DRAINAGE SYSTEM&SPLASHBLOCKS -ADDRESS
Documents & Images
Date Uploaded File Type Document Name
11/29/2016 Receipt Receipt for transaction: 2016-006968
11/29/2016 Letter Codes Building Permit
11/30/2016 Plot Plan DOC113016-001
11/30/2016 Letter Inspection Summary
12/14/2016 Letter Inspection Summary
01/13/2017 Letter Inspection Summary
01/26/2017 Letter Inspection Summary
01/27/2017 Letter Inspection Summary
01/31/2017 Letter Inspection Summary
02/02/2017 Letter Inspection Summary
03/03/2017 Receipt Receipt for transaction: 2017-000736
03/03/2017 Letter Codes Building Permit
03/03/2017 Letter Codes Building Permit
03/08/2017 Letter Inspection Summary
03/15/2017 Letter Inspection Summary
06/07/2017 Letter Inspection Summary
07/06/2017 Letter Codes Temporary Certificate of Occupancy
09/06/2017 Letter Field Certificate of Occupancy
09/08/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home