Permit Application Status

PRRES20162575


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162575
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY FINISHED BASEMENT COVERED DECK
10/06/2016
10/13/2016
05/25/2018
Locations
Contacts
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/12/2016
James Fletchall
Plot Plan Review Rejected 10/10/2016 10/11/2016
James Fletchall
Plot Plan Review (P&D) Approved 10/10/2016 10/10/2016
Christina Stanton
Residential Plan Review Approved 10/10/2016 10/06/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $878.42 $878.42 Paid 10/13/2016
8331507-Sewer Connection Fee $420.00 $420.00 Paid 10/13/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 10/13/2016
Water Meter Fee $405.36 $405.36 Paid 10/13/2016
Right of Way Permit Fee $75.00 $75.00 Paid 10/13/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/9/2016 (11:30) 11/9/2016 at 11:45 AM 11/09/2016
Underslab Plumbing Inspection - Residential Passed 11/23/2016 11/23/2016 11/23/2016
Sewer Service Inspection - R Passed 11/29/2016 (11:00) 11/29/2016 11/29/2016
Water Service Inspection - R Passed 11/30/2016 (11:00) 11/30/2016 11/30/2016
All Rough Inspection - Residential Failed 3/13/2017 3/13/2017 03/13/2017
Misc
Corrective Action Required
03/13/2017
-INSTALL TRUSS HANGERS PER THE LAYOUT, SEVERAL MISSING -FIREBLOCK REAR WALL BASEMENT -NAIL CORNER STUDS -B-VENT CLEARANCE IN GARAGE -INSTALL ANCHOR BOLTS 2 PER PLATE SECTION, MINIMUM 1 WITHIN 6" OF PLATE BREAK -H CLIP BOTH SIDES OF GIRDER TRUSSES
Gas Service Inspection - Residential Failed 3/13/2017 3/13/2017 03/13/2017
Electrical Service Inspection Passed 3/13/2017 3/13/2017 03/13/2017
All Rough Inspection - Residential Failed 3/29/2017 3/29/2017 03/29/2017
Misc
Corrective Action Required
03/13/2017
-INSTALL TRUSS HANGERS PER THE LAYOUT, SEVERAL MISSING **INSTALL CORNER TRUSS HANGERS; INSTALL THE CORRECT HANGER FOR THE TRIPLE TRUSS GIRDER ABOVE FRONT BED -FIREBLOCK REAR WALL BASEMENT **FB WALL VERTICALLY AT INTERVAL NO MORE THAN TEN FT -NAIL CORNER STUDS **NOT DONE -B-VENT CLEARANCE IN GARAGE **MIN. 1" CLEARANCE -INSTALL ANCHOR BOLTS 2 PER PLATE SECTION, MINIMUM 1 WITHIN 6" OF PLATE BREAK **LOOK AT THE REAR WALL SILL PLATE IN BASEMENT -H CLIP BOTH SIDES OF GIRDER TRUSSES **INSTALL 2 TIE DOWN CLIPS FOR GIRDER END AT GARAGE WALL
Gas Service Inspection - Residential Failed 3/29/2017 3/29/2017 03/29/2017
Misc
Corrective Action Required
03/29/2017
-PRESSURE IS BELOW TEN PSI (~5). FIX LEAKAGE AND RETEST
All Rough Inspection - Residential Failed 3/31/2017 3/31/2017 03/31/2017
Misc
Corrective Action Required
03/29/2017
-INSTALL TRUSS HANGERS PER THE LAYOUT, SEVERAL MISSING **INSTALL CORNER TRUSS HANGERS. SEE THE LAYOUT PLAN FOR DETAIL
Gas Service Inspection - Residential Failed 4/17/2017 4/17/2017 04/17/2017
Misc
Corrective Action Required
03/29/2017
-PRESSURE IS BELOW TEN PSI (~5). FIX LEAKAGE AND RETEST
All Rough Inspection - Residential Failed 4/18/2017 4/18/2017 04/18/2017
Misc
Corrective Action Required
03/31/2017
DO NOT COVER UNTIL GAS PRESSURE CAN HOLD AND TEST IS APPROVED.
Gas Service Inspection - Residential Failed 04/18/2017
Misc
Corrective Action Required
04/17/2017
-PRESSURE IS BELOW TEN PSI (~5). FIX LEAKAGE AND RETEST
All Rough Inspection - Residential Failed 4/20/2017 4/20/2017 04/20/2017
Misc
Corrective Action Required
04/18/2017
DO NOT COVER UNTIL GAS PRESSURE CAN HOLD AND TEST IS APPROVED.
Gas Service Inspection - Residential Failed 4/20/2017 4/20/2017 04/20/2017
Misc
Corrective Action Required
04/18/2017
-PRESSURE IS BELOW TEN PSI (~5). FIX LEAKAGE AND RETEST 4/20- 4lbs psi, valve 1/2 open at firepalce, no protection at fireplace wall to protect wardflex.
Gas Piping Inspection - Residential Passed 4/24/2017 4/24/2017 04/24/2017
Gas Service Inspection - Residential Passed 4/24/2017 4/24/2017 04/24/2017
Misc
Resolved
04/24/2017
4/20- 4lbs psi, valve 1/2 open at firepalce, no protection at fireplace wall to protect wardflex.
All Rough Inspection - Residential Passed 4/24/2017 4/24/2017 04/24/2017
Misc
Resolved
04/24/2017
DO NOT COVER UNTIL GAS PRESSURE CAN HOLD AND TEST IS APPROVED. **HELD >10PSI ON 4/24/2017. OK TO COVER.
Sidewalk Inspection Partial 4/24/2017 4/24/2017 04/24/2017
Informational
04/24/2017
Tom Chandler 04/24/2017 4:20 PM Inspected forms only.
Sidewalk Inspection Passed 4/28/2017 04/27/2017
Informational
04/27/2017
Tom Chandler 04/27/2017 10:02 AM Sidewalk has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Failed 9/15/2017 9/15/2017 at 10:21 AM 09/15/2017
Misc
Corrective Action Required
09/15/2017
-MASTER DECK DOOR NEEDS SECURITY SCREWS -REAR GRADE NEEDS 6 INCHES CLEARANCE FROM SIDING -WALKOUT EXTERIOR RECEPTACLE NEEDS COVER.
Occupancy Inspection - Codes Residential Failed 11/15/2017 11/15/2017 11/15/2017
Misc
Corrective Action Required
09/15/2017
-REAR GRADE NEEDS 6 INCHES CLEARANCE FROM SIDING INSTALLED ROCK, CREATED A POND FOR STORM WATER NEXT TO FOUNDATION AND DOESN'T HAVE 6" OF FALL AWAY FROM THE FOUNDATION.
Occupancy Inspection - Codes Residential Full C of O 5/25/2018 5/25/2018 at 7:20 AM 05/25/2018
Misc
Corrective Action Required
11/15/2017
-REAR GRADE NEEDS 6 INCHES CLEARANCE FROM SIDING INSTALLED ROCK, CREATED A POND FOR STORM WATER NEXT TO FOUNDATION AND DOESN'T HAVE 6" OF FALL AWAY FROM THE FOUNDATION.
Driveway Inspection Passed 5/30/2018 at 9:10 AM 05/30/2018
Informational
05/30/2018
John DiMauro 05/30/2018 10:13 AM The driveway approach cross slope is less than 2.0 percent. A pre pour inspection was never called in and done on the approach. The sub grade, concrete type and thickness cannot be verified to be correct.
Documents & Images
Date Uploaded File Type Document Name
10/13/2016 Receipt Receipt for transaction: 2016-006379
10/13/2016 Letter Codes Building Permit
10/14/2016 Plot Plan DOC101416-007
11/03/2016 Engineer Report/Study DOC110316-011
11/09/2016 Letter Inspection Summary
11/10/2016 Engineer Report/Study DOC111016-001
11/23/2016 Letter Inspection Summary
11/29/2016 Letter Inspection Summary
03/13/2017 Letter Inspection Summary
03/29/2017 Letter Inspection Summary
03/31/2017 Letter Inspection Summary
04/17/2017 Letter Inspection Summary
04/18/2017 Letter Inspection Summary
04/20/2017 Letter Inspection Summary
04/24/2017 Letter Inspection Summary
04/27/2017 Letter PW-Daily Inspection Summary
09/15/2017 Letter Inspection Summary
11/15/2017 Letter Inspection Summary
05/04/2018 Letter Codes 10 Day Letter
05/25/2018 Letter Codes Final Certificate of Occupancy
05/29/2018 Letter Codes Final Certificate of Occupancy
05/30/2018 Letter DE-Daily Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home