Permit Application Status

PRRES20162334


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162334
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE WITH COVERED DECK
09/13/2016
10/05/2016
12/06/2017
Locations
Contacts
BRIAN CHANEY CONSTRUCTION, LLC, Address:PO BOX 646, Phone:(816) 838-0821  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
O'CONNELL ELECTRIC LLC, Address:11017 S ALLEY JACKSON RD, Phone:(816) 547-4706  
LRW PLUMBING LLC, Address:20631 W 319TH ST, Phone:(913) 568-7737  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 09/15/2016 09/15/2016
Hector Soto Jr.
Plot Plan Review Approved 09/15/2016 09/15/2016
James Fletchall
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $884.25 $884.25 Paid 10/05/2016
Right of Way Permit Fee $75.00 $75.00 Paid 10/05/2016
8331507-Sewer Connection Fee $420.00 $420.00 Paid 10/05/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 10/05/2016
Water Meter Fee $405.36 $405.36 Paid 10/05/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/24/2016 (10:00) 10/24/2016 10/24/2016
Underslab Plumbing Inspection - Residential Passed 11/10/2016 11/10/2016 11/10/2016
Piers/Caissons Inspection - Residential Passed 11/16/2016 (8:15) 11/16/2016 11/16/2016
Sewer Service Inspection - R Passed 11/22/2016 (2:30) 11/22/2016 11/22/2016
Water Service Inspection - R Passed 11/28/2016 (2:15) 11/28/2016 11/28/2016
All Rough Inspection - Residential Failed 2/22/2017 2/22/2017 02/22/2017
Misc
Corrective Action Required
02/22/2017
***EROSION CONTROL ALONG THE BACK AND STREET. NO FURTHER INSPECTION IF NOT IN COMPLIANCE*** FRAMING: -HAVE TRUSS PACKAGE ON SITE -GARAGE PORTAL WALLS: NAIL SHEATHING TO SILL PLATE 8D@3" OC -TIE DOWN ALL TRUSSES AND GIRDERS AT BOTH ENDS -BRACE ALL INTERIOR WALLS WITH X OR V CONFIGURATION -PROVIDE SECURITY BLOCKING FOR DECK DOOR -THE WINDOW WITHIN 24" OF DECK DOOR MUST BE TEMPERED GLASS WINDOW -FRAME CS-PF WALLS PER DETAIL -SOLIDBLOCK ALL LAPPED JOISTS ABOVE I BEAM IN BASEMENT -FIREBLOCK ALL BASEMENT WALL FROM CEILING FUR-DOWN SPACE -STAIR STRINGERS IN CONTACT WITH CONCRETE ELECTRICAL: -NOT READY FOR INSPECTION. PROTECT ALL WIRING PER CODE (ALSO OUTSIDE MASTER BED DOOR AT TOP PLATE AND ANYWHERE WITHIN 1.25" OF WOOD SURFACE). COMPLETE ALL CIRCUITS THROUGHOUT HOUSE. BOND GAS PIPING OER WARDFLEX INSTRUCTION. ACCESS TO UFER CONNECTION WILL BE REQUIRED AT FINAL INSPECTION. PROTECT WIRING WITHIN 6 FT OF ATTIC ACCESS PLUMBING: -VENT WATER CLOSET FRONT BATH PER CODE. CANNOT WET VENTING FOR THIS CONFIGURATION, 'CAUSE WET VENTING ONLY WORKS FOR HORIZONTAL DRAIN (NO DROP). -PROVIDE 3" VENT FOR BUILDING DRAIN THROUGH ROOF -SECURE CSST GAS LINE NEAR FIREPLACE ENTRY MECHANICAL: -SEAL RETURN AIR PENETRATION ABOVE BASEMENT BATH ***DO NOT INSULATE
Gas Service Inspection - Residential Passed 2/22/2017 02/22/2017
Electrical Service Inspection Passed 2/22/2017 02/22/2017
All Rough Inspection - Residential Failed 2/27/2017 2/27/2017 02/27/2017
Misc
Corrective Action Required
02/22/2017
FRAMING: -HAVE TRUSS PACKAGE ON SITE **TIE DOWN ALL TRUSSES AND GIRDERS PER PLAN. SEE TRUSS DETAIL FOR THE UPLIFT FORCES AND TIE THE GIRDERS DOWN ACCORDINGLY -TIE DOWN ALL TRUSSES AND GIRDERS AT BOTH ENDS -THE WINDOW WITHIN 24" OF DECK DOOR MUST BE TEMPERED GLASS WINDOW -FRAME CS-PF WALLS PER DETAIL **NAIL THE SIDING 3" OC; STRAP INNER SIDE OF CS-PF WALL -FIREBLOCK ALL BASEMENT WALL FROM CEILING FUR-DOWN SPACE ELECTRICAL: -PROTECT WIRING AT FRONT DOOR -INSTALL AN OUTDOOR RECEPTACLE AT REAR OF HOUSE MECHANICAL: -SEAL RETURN AIR PENETRATION ABOVE BASEMENT BATH **SEAL AT THE 3" PVC PENETRATION THROUGH THE RETURN AIR SPACE. ***OK TO INSULATE
All Rough Inspection - Residential Partial 3/2/2017 03/02/2017
Misc
Corrective Action Required
02/27/2017
CHECK AT FINAL: -THE WINDOW WITHIN 24" OF DECK DOOR MUST BE TEMPERED GLASS WINDOW -FRAME CS-PF WALLS PER DETAIL **NAIL THE SIDING 3" OC; STRAP INNER SIDE OF CS-PF WALL ***OK TO ROCK
Driveway Inspection Passed 4/7/2017 4/7/2017 04/10/2017
All Rough Inspection - Residential Passed 11/13/2017
Misc
Resolved
11/13/2017
CHECK AT FINAL: -THE WINDOW WITHIN 24" OF DECK DOOR MUST BE TEMPERED GLASS WINDOW -FRAME CS-PF WALLS PER DETAIL **NAIL THE SIDING 3" OC ***OK TO ROCK
Occupancy Inspection - Codes Residential Failed 11/13/2017 at 9:25 AM 11/13/2017
Misc
Corrective Action Required
11/13/2017
-OBTAIN LAWN IRRIGATION PERMIT AND SUBMIT TO CITY THE BACKFLOW VALVE TEST REPORT -ADDRESS -SEAL EXTERIOR WALL PENETRATIONS AND LIGHTS -INSTALL PROPER SCREWS FOR ALL EXTERIOR LIGHTS -INSTALL SPLASHBLOCKS. MAKE SURE THE REAR SPLASHBLOCKS DISCHARGE MIN. 3 FT AWAY FROM HOUSE -INSTALL A RECEPTACLE (SUPPLIED BY SMALL APPLIANCE CIRCUIT) FOR THE KITCHEN ISLAND -INSTALL A RECEPTACLE WITHIN 3 FT OF MASTER BATH SINK -INSTALL WATER HAMMERING ARRESTOR FOR THE DISH WASHER -INSTALL HANDRAIL FOR THE GARAGE STAIR -GARAGE DOOR MUST BE SELF-CLOSING&LATCH -INSTALL SECURITY STRIKE PLATE FOR BASEMENT EGRESS DOOR WITH 3" SCREWS INTO STUDS -RECEPTACLES WITHIN SIX FT OF THE WET BAR SINK MUST BE GFCI -INSTALL OVEN BREAKER LOCK -INSTALL WATER HEATER BREAKER LOCK -SECURE SE CABLE WITHIN 12" OF PANEL -WHERE IS THE UFER GROUNDING CONNECTION? -SEAL WATER SERVICE LINE PENETRATION; SECURE PEX LINES AT FOUNDATION WALL -INSTALL ANTI-BACKFLOW DEVICE FOR THE BASEMENT HOSE BIBB -ANCHOR ALL BASEMENT COLUMNS -REMOVE EXPOSED PAPER FACING FROM INSULATION
Occupancy Inspection - Codes Residential Temporary C of O 11/30/2017 11/30/2017 at 8:00 AM 11/30/2017
Misc
Corrective Action Required
11/13/2017
-INSTALL AN INTERBONDING TERMINAL BLOCK NEAR SERVIDE METER -INSTALL OVEN AND WATEWR HEATER BREAKER LOCKS **THE DEVICES MUST NOT ONLY BE ABLE TO LOCK THE BREAKER IN THE OPEN POSITION, IT ALSO MUST ALLOW THE BREAKER TO TRIP -WHERE IS THE UFER GROUNDING CONNECTION? **THE GROUNDING CONNECTION MUST BE ACCESSIBLE
Occupancy Inspection - Codes Residential Full C of O 12/6/2017 12/6/2017 at 10:40 AM 12/06/2017
Misc
Resolved
12/06/2017
-INSTALL AN INTERBONDING TERMINAL BLOCK NEAR SERVIDE METER -INSTALL OVEN AND WATEWR HEATER BREAKER LOCKS **THE DEVICES MUST NOT ONLY BE ABLE TO LOCK THE BREAKER IN THE OPEN POSITION, IT ALSO MUST ALLOW THE BREAKER TO TRIP -WHERE IS THE UFER GROUNDING CONNECTION? **THE GROUNDING CONNECTION MUST BE ACCESSIBLE
Documents & Images
Date Uploaded File Type Document Name
10/05/2016 Receipt Receipt for transaction: 2016-006247
10/05/2016 Letter Codes Building Permit
10/05/2016 Receipt Receipt for transaction: 2016-006265
10/06/2016 Plot Plan DOC100616-007
10/24/2016 Letter Inspection Summary
11/10/2016 Letter Inspection Summary
11/16/2016 Letter Inspection Summary
11/22/2016 Letter Inspection Summary
02/22/2017 Letter Inspection Summary
02/27/2017 Letter Inspection Summary
03/02/2017 Letter Inspection Summary
04/10/2017 Letter Inspection Summary
11/13/2017 Letter Inspection Summary
11/30/2017 Letter Codes Temporary Certificate of Occupancy
12/06/2017 Letter Field Certificate of Occupancy
12/07/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home