Permit Application Status

PRRES20162330


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20162330
Building Permit - Residential
Certificate of Occupancy
SILVERSTONE DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY COVERED DECK
09/13/2016
10/05/2016
04/02/2018
Locations
Contacts
SILVERSTONE DEVELOPMENT LLC, Address:PO BOX 219119  
BRIAN CHANEY CONSTRUCTION, LLC, Address:PO BOX 646, Phone:(816) 838-0821  
LRW PLUMBING LLC, Address:20631 W 319TH ST, Phone:(913) 568-7737  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
O'CONNELL ELECTRIC LLC, Address:11017 S ALLEY JACKSON RD, Phone:(816) 547-4706  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 09/15/2016 09/15/2016
Hector Soto Jr.
Plot Plan Review Approved 09/15/2016 09/15/2016
James Fletchall
Residential Plan Review Approved 09/15/2016 09/13/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $797.48 $797.48 Paid 10/05/2016
8331507-Sewer Connection Fee $420.00 $420.00 Paid 10/05/2016
Water Tap Fee $3,310.00 $3,310.00 Paid 10/05/2016
Water Meter Fee $405.36 $405.36 Paid 10/05/2016
Right of Way Permit Fee $75.00 $75.00 Paid 10/05/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/24/2016 10/24/2016 10/24/2016
Underslab Plumbing Inspection - Residential Passed 11/10/2016 11/10/2016 11/10/2016
Piers/Caissons Inspection - Residential Passed 11/16/2016 (8:15) 11/16/2016 11/16/2016
Sewer Service Inspection - R Passed 11/23/2016 (3:00) 11/23/2016 11/23/2016
Water Service Inspection - R Passed 11/28/2016 (2:15) 11/28/2016 11/28/2016
Electrical Service Inspection Not Ready 5/19/2017 05/19/2017
Gas Service Inspection - Residential Passed 5/19/2017 05/19/2017
All Rough Inspection - Residential Failed 5/19/2017 5/19/2017 05/19/2017
Misc
Corrective Action Required
05/19/2017
***INSTALL EROSION CONTROL AT FRONT AND BACK FRAMING: -CS-PF WALLS AT FRONT: NAIL SHEATHING TO STUD AND RIM PER DRAWING; STRAP HEADER -PROVIDE CS-PF WALL AT REAR DINING AREA CORNER -FIREBLOCKING: FB FIREPLACE SPACE FROM ATTIC; FB ALL BASEMENT WALL SPACE FROM CEILING FURDOWN SPACE -BRACE LVL BEAM ENDS FROM ROTATION -INSTALL FULL 3 STUD SUPPORT FOR LVL AT KITCHEN/STAIR WALL CORNER TO I BEAM BELOW -INSTALL 3 STUD SUPPORT FOR LVL AT FOYER WALL (SAME LVL BEAM) -INSTALL SECURITY BLOCKING FOR DECK DOOR -DOUBLE UP THE GARAGE ATTIC ACCESS TRIMMER JOISTS -NAIL THE GARAGE CEILING JOIST-RAFTER CONNECTIONS -INSTALL LVL BEAM AT STAIR PER PLAN -BRACE INTERIOR WALLS PER PLAN -COMPLETE FRAMING AT FRONT BATH SHOWER -NOTCHED JOIST BELOW FROTN BATH SHOWER PLUMBING: -PROTECT WATER LINES AT MASTER BATH SINK WALL AND AT BASEMENT BATH TUB ELECTRICAL: -INSTALL CEILING LIGHT&FAN BOX IN ALL BEDROOMS -THE 20 AMP CIRCUIT SERVING THE KITCHEN COUNTERTOP AND DINING AREA CANNOT FEED ANY OTHER RECEPTACLES, EXCEPT RECEPTACLES IN LIKE AREAS, REFRIGERATOR, OR CLOCK. -BOND GAS LINE PER CSST GAS INSTALLATION ***DO NOT INSULATE
All Rough Inspection - Residential Failed 5/30/2017 5/30/2017 05/30/2017
Misc
Corrective Action Required
05/19/2017
-PROVIDE CS-PF WALL AT REAR DINING AREA CORNER -FIREBLOCKING: FB ALL BASEMENT WALL SPACE FROM CEILING FURDOWN SPACE AT FRONT BASEMENT BED CLOSET -DOUBLE UP THE GARAGE ATTIC ACCESS TRIMMER JOISTS -INSTALL LVL BEAM AT STAIR PER PLAN -NOTCHED JOIST BELOW FRONT BATH SHOWER **SUPPORT JOIST AS DISCUSSED ***OK TO INSULATE
Electrical Service Inspection Passed 5/30/2017 05/30/2017
All Rough Inspection - Residential Partial 6/5/2017 6/5/2017 06/05/2017
Misc
Corrective Action Required
05/30/2017
-PROVIDE CS-PF WALL AT REAR DINING AREA CORNER **INSTALL THE STRAP AT THE INNER SIDE OF THE CS-PF WALL. SEE DRAWING ***OK TO ROCK
Driveway Inspection Passed 6/15/2017 6/15/2017 06/15/2017
Investigation Inspection Complete 12/12/2017 12/12/2017
All Rough Inspection - Residential Passed 03/16/2018
Misc
Resolved
03/16/2018
-PROVIDE CS-PF WALL AT REAR DINING AREA CORNER **INSTALL THE STRAP AT THE INNER SIDE OF THE CS-PF WALL. SEE DRAWING ***OK TO ROCK
Occupancy Inspection - Codes Residential Failed 3/16/2018 3/16/2018 at 8:25 AM 03/16/2018
Miscellaneous Correction
Corrective Action Required
03/16/2018
-WATER SERVICE: RAISE THE LID TO GRADE LEVEL; SHALL CLEAN OUT ALL THE MUD FROM THE WATER SERVICE PIT; FILL BOTTOM OF PIT WITH GRAVEL PER CITY STANDARD -LOCATE AND MAKE ACCESSIBLE THE SEWER TRACER CONNECTION ACCESS. INSTALL THAT CITY-APPROVED ACCESS -DECK: INSTALL DOUBLE PLIES BEAM; INSTALL TWO 1/2" THROUGH BOLTS AT EACH DECK POST CONNECTION; FASTEN DECK POSTS TO SUPPORT BRACKET -SEAL EXTERIOR WALL PENETRATIONS; SEAL EXTERIOR LIGHTS -INSTALL INTERBONDING SYSTEM TERMINAL NEAR SERVICE -INSTALL A RECEPTACLE WITHIN 25 FT OF AC UNIT, AT REAR SIDE OF THE HOUSE AND REACHABLE&WITHIN 6.5 FT OF GRADE -INSTALL SECURITY STRIKE PLATE FOR THE DECK DOOR -SUPPORT KITCHEN COIUNTERTOP RECEPTACLE YOKE -LOOP UP AND SECURE THE DISH WASHER DRAIN; INSTALL A WATER ANTI-HAMMERING DEVICE FOR DISH WASHER -INSTALL BREAKER LOCK FOR OVEN -INSTALL CLOTHES WASHER RECEPTACLE FACE PLATE -GARAGE DOOR SHALL BE SELF-CLOSING -INSTALL HANDRAIL FOR GARAGE STAIR -SUPPORT RECEPTACLE AT WET BAR -SUPPORT EXPANSION TANK -SECURELY FASTEN THE WATER HEATER FLNC RACEWAT
Occupancy Inspection - Codes Residential Temporary C of O 3/23/2018 at 10:25 AM 03/23/2018
Miscellaneous Correction
Corrective Action Required
03/16/2018
-WATER SERVICE: SHALL CLEAN MUD OFF THE WATER SERVICE; FILL BOTTOM OF PIT WITH GRAVEL PER CITY STANDARD -INSTALL SECURITY STRIKE PLATE FOR THE DECK DOOR -LOOP UP AND SECURE THE DISH WASHER DRAIN; -SUPPORT EXPANSION TANK **I NEED TO SEE THE INSTALLATION MANUAL OF THE EXPANSION TANK
Occupancy Inspection - Codes Residential Temporary C of O 3/29/2018 3/29/2018 at 10:51 AM 03/29/2018
Miscellaneous Correction
Corrective Action Required
03/23/2018
-INSTALL SECURITY STRIKE PLATE FOR THE DECK DOOR -FIND THE COVERED RECEPTACLE AND INSTALL THE RECEPTACLE AT WALL (END OF STAIR OPENING)
Occupancy Inspection - Codes Residential Full C of O 4/2/2018 04/02/2018
Miscellaneous Correction
Resolved
04/02/2018
-INSTALL SECURITY STRIKE PLATE FOR THE DECK DOOR -FIND THE COVERED RECEPTACLE AND INSTALL THE RECEPTACLE AT WALL (END OF STAIR OPENING)
Documents & Images
Date Uploaded File Type Document Name
10/05/2016 Receipt Receipt for transaction: 2016-006248
10/05/2016 Letter Codes Building Permit
10/06/2016 Plot Plan DOC100616-008
10/24/2016 Letter Inspection Summary
11/10/2016 Letter Inspection Summary
11/16/2016 Letter Inspection Summary
11/23/2016 Letter Inspection Summary
11/28/2016 Letter Inspection Summary
05/19/2017 Letter Inspection Summary
05/30/2017 Letter Inspection Summary
06/05/2017 Letter Inspection Summary
06/15/2017 Letter Inspection Summary
06/20/2017 Engineer Report/Study DOC062017-001
03/16/2018 Letter Inspection Summary
03/23/2018 Letter Codes Temporary Certificate of Occupancy
04/02/2018 Letter Field Certificate of Occupancy
04/03/2018 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home