Permit Application Status

PRRES20160494


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20160494
Building Permit - Residential
Certificate of Occupancy
MCDC PARTNERS LLC
NEW SINGLE FAMILY
NEW SINGLE FAMILY WITH DECK
03/11/2016
03/16/2016
07/21/2017
Locations
Contacts
MCDC PARTNERS LLC, Address:120 SE 30TH ST  
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/17/2016 03/16/2016
James Fletchall
Plot Plan Review Rejected 03/15/2016 03/14/2016
James Fletchall
Plot Plan Review (P&D) Approved 03/15/2016 03/14/2016
Christina Stanton
Residential Plan Review Approved 03/15/2016 03/11/2016
Jonathon Hilton
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,096.91 $1,096.91 Paid 03/16/2016
Right of Way Permit Fee $75.00 $75.00 Paid 03/16/2016
8331507-Sewer Connection Fee $570.00 $570.00 Paid 03/16/2016
Water Tap Fee $3,214.00 $3,214.00 Paid 03/16/2016
Water Meter Fee $377.18 $377.18 Paid 03/16/2016
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/23/2016 (11:30) 3/23/2016 03/23/2016
Underslab Plumbing Inspection - Residential Not Ready 4/7/2016 4/7/2016 04/07/2016
Corrective Action Required
04/07/2016
PROVIDE ACCESS , NOT BACK FILLED. POST ADDRESS.
Sewer Service Inspection - R Passed 4/7/2016 (9:15) 4/7/2016 04/07/2016
Water Service Inspection - R Passed 4/8/2016 (11:00) 4/8/2016 04/08/2016
Underslab Plumbing Inspection - Residential Passed 4/12/2016 4/12/2016 04/12/2016
Gas Service Inspection - Residential Passed 6/10/2016 06/10/2016
Electrical Service Inspection Passed 6/10/2016 06/10/2016
All Rough Inspection - Residential Failed 6/10/2016 06/10/2016
Misc
Corrective Action Required
06/10/2016
**INSTALL & RESTORE DAMAGED EROSION CONTROL ADJACENT TO NEIGHBOR FRAMING: -NAIL GARAGE PORTAL BRACE WALL SHEATHING TO SILL PLATES -INSTALL JOIST HANGERS AT JOIST TO I BEAM CONNECTIONS NEAR FOYER&STAIR; NAIL ALL HANGERS AT I BEAM CONNECTIONS -NAIL HANGER AT LVL CONNECTION ABOVE DUCT/B-VENT CHASE -NAIL HANGER ABOVE 1ST FL BED -INSTALL 4 STUD SUPPORT FOR TRIPLE LVL ABOVE 1ST FL BED -INSTALL SUPPORT COLUMN FOR GARAGE I BEAM -FIREBLOCK PLUMBING CHASE ADJACENT TO SHOWER FROM GARAGE CEILING SPACE -DECK DOOR: FILL IN GAPS AT HINGES WITH WOOD; BLOCK JAMB STUD TO CORNER -2ND FL FRONT BED GABLE WALL STUDS ARE NOT CONTINUOUS FROM FLOOR TO CEILING. -ADD ANOTHER TIE DOWN DEVICE FOR GIRDER ABOVE 2ND FL FRONT BED BATH -INSTALL SNOW BLOCKINGS AT FLASHINGS IN MASTER BED AND SOUTH CLOSET -INSTALL HANGERS FOR JOISTS BELOW FIREPLACE -STRAP OVER CUT WALL TOP PLATES ABOVE BASEMENT WINDOWS AND NAIL ON EACH SIDE WITH 8-16D NAILS. -INSTALL SUPPORT COLUMN FOR I BEAM AT BASEMENT STAIR WALL; SHALL VERIFY THAT THE PAD IS INSTALLED UNDERNEATH -INSTALL SOLID 2X SUPPORT UNDERNEATH ALL POINT LOAD TO I BEAM IN BASEMENT PLUMBING: -COMPLETE GAS INSTALLATION TO FIREPLACE -PROTECT PLUMBING IN MASTER BED -VENT THE 1ST FL SHOWER TRAP BEFORE CONNECTION TO WASTE STACK ELECTRICAL: -OVERFILLED ELECTRICAL BOX AT CORNER WALL BETWEEN FRONT DINING&KITCHEN -REWIRE CIRCUIT TO SWITCH AT NORTH MASTER CLOSET; SECURELY FASTEN ALL WIRING WITHIN 8" OF BOXES -PROTECT WIRING ACROSS CEILING WITHIN 6 FT OF ATTIC ACCESS **OK TO INSULATE
Driveway Inspection Partial 6/15/2016 06/15/2016
All Rough Inspection - Residential Failed 6/17/2016 6/17/2016 06/17/2016
Misc
Corrective Action Required
06/10/2016
-INSTALL 4 STUD SUPPORT FOR TRIPLE LVL ABOVE 1ST FL BED -2ND FL FRONT BED GABLE WALL STUDS ARE NOT CONTINUOUS FROM FLOOR TO CEILING. -ADD ANOTHER TIE DOWN DEVICE FOR GIRDER ABOVE 2ND FL FRONT BED BATH -INSTALL SOLID 2X SUPPORT UNDERNEATH ALL POINT LOAD TO I BEAM IN BASEMENT **OK TO INSULATE
Driveway Inspection Passed 6/22/2016 06/22/2016
PW-Misc
Informational
06/22/2016
Tom Chandler 06/22/2016 11:38 AM Drive way has been completed and inspected.
All Rough Inspection - Residential Failed 6/24/2016 6/24/2016 06/24/2016
Misc
Corrective Action Required
06/17/2016
-INSTALL 4 STUD SUPPORT FOR TRIPLE LVL ABOVE 1ST FL BED EAST END -INSTALL SOLID 2X SUPPORT UNDERNEATH ALL POINT LOAD TO I BEAM IN BASEMENT **OK TO INSULATE
All Rough Inspection - Residential Failed 06/24/2016
Misc
Corrective Action Required
06/24/2016
-INSTALL 4 STUD SUPPORT FOR TRIPLE LVL ABOVE 1ST FL BED EAST END -INSTALL SOLID 2X SUPPORT UNDERNEATH ALL POINT LOAD TO I BEAM IN BASEMENT **OK TO INSULATE
All Rough Inspection - Residential Failed 6/28/2016 06/28/2016
Misc
Corrective Action Required
06/24/2016
-INSTALL 4 STUD SUPPORT FOR TRIPLE LVL ABOVE 1ST FL BED EAST END*****STILL NOT DONE**** -INSTALL SOLID 2X SUPPORT UNDERNEATH ALL POINT LOAD TO I BEAM IN BASEMENT ***DREW ON SUB FLOOR WITH SHARPIE AN AAROW TO POINT LOADS AND IN FIRST FLOOR EXTERIOR WALL WHERE 3 STUDS INSTALLED INSTEAD OF 4********* DO NOT ROCK
All Rough Inspection - Residential Passed 6/29/2016 6/29/2016 06/29/2016
Misc
Resolved
06/29/2016
-INSTALL 4 STUD SUPPORT FOR TRIPLE LVL ABOVE 1ST FL BED EAST END*****STILL NOT DONE**** -INSTALL SOLID 2X SUPPORT UNDERNEATH ALL POINT LOAD TO I BEAM IN BASEMENT ***DREW ON SUB FLOOR WITH SHARPIE AN AAROW TO POINT LOADS AND IN FIRST FLOOR EXTERIOR WALL WHERE 3 STUDS INSTALLED INSTEAD OF 4********* DO NOT ROCK
Sidewalk Inspection Partial 10/18/2016 10/19/2016
Sidewalk Inspection Partial 10/26/2016 10/31/2016
Sidewalk Inspection Passed 11/7/2016 02/28/2017
Occupancy Inspection - Codes Residential Failed 6/28/2017 6/28/2017 06/28/2017
Misc
Corrective Action Required
06/28/2017
1. Seal exterior penetrations - East side. 2. Elec receptacle face plate - Dining room. 3. Secure elec receptacle yokes - throughout. 4. Oven breaker needs LO/TO bracket. 5. Closet light fixture in southwest BR too close to shelf. 6. Secure sprinkler piping near connection with main water service. 7. Fill / Seal hole at base of foundation wall - north wall.
Occupancy Inspection - Codes Residential Full C of O 7/21/2017 7/21/2017 07/21/2017
Misc
Resolved
07/21/2017
1. Seal exterior penetrations - East side. 2. Elec receptacle face plate - Dining room. 3. Secure elec receptacle yokes - throughout. 4. Oven breaker needs LO/TO bracket. 5. Closet light fixture in southwest BR too close to shelf. 6. Secure sprinkler piping near connection with main water service. 7. Fill / Seal hole at base of foundation wall - north wall.
Documents & Images
Date Uploaded File Type Document Name
03/16/2016 Receipt Receipt for transaction: 2016-000735
03/16/2016 Letter Codes Building Permit
03/17/2016 Plot Plan DOC031716
03/23/2016 Letter Inspection Summary
04/07/2016 Letter Inspection Summary
04/08/2016 Letter Inspection Summary
04/12/2016 Letter Inspection Summary
06/10/2016 Letter Inspection Summary
06/17/2016 Letter Inspection Summary
06/21/2016 Engineer Report/Study DOC062116-021
06/22/2016 Letter PW-Daily Inspection Summary
06/24/2016 Letter Inspection Summary
06/28/2016 Letter Inspection Summary
06/29/2016 Letter Inspection Summary
02/28/2017 Letter PW-Daily Inspection Summary
06/28/2017 Letter Inspection Summary
07/21/2017 Letter Field Certificate of Occupancy
07/24/2017 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home