Summary
PRRES20141418
Building Permit - Residential
Certificate of Occupancy
FRITCHIE LAND DEVELOPMENT LLC
NEW SINGLE FAMILY
HOUSE *ADDED UNCOVERED DECK
05/29/2014
06/04/2014
03/12/2015
Locations
Contacts
SUMMIT CUSTOM HOMES LLC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
FRITCHIE LAND DEVELOPMENT LLC, Address:1412 NE VALLEY FORGE DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review (P&D) Approved 06/03/2014 06/04/2014
Christina Stanton
Plot Plan Review Approved 06/05/2014 06/04/2014
Gene Williams, P.E.
Plot Plan Review Rejected 06/02/2014 06/03/2014
Gene Williams, P.E.
Corrective Action Required
06/03/2014

1. The rear utility easement appears to be incorrect.
Plot Plan Review (P&D) Rejected 06/02/2014 05/30/2014
Christina Stanton
Rear UE is labeled incorrectly.
Residential Plan Review Approved 06/02/2014 05/29/2014
Tara Mitchell
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $874.18 $874.18 Paid 06/04/2014
$874.18
9110073-Right of Way Permit Fee $60.00 $60.00 Paid 06/04/2014
$60.00
8331507-Sewer Connection Fee $570.00 $570.00 Paid 06/04/2014
$570.00
8331401-Water Tap Fee $3,116.00 $3,116.00 Paid 06/04/2014
$3,116.00
8350015-Water Meter Fee $289.76 $289.76 Paid 06/04/2014
$289.76
9110078-Valuation Fee New Single Family $7.08 $7.08 Paid 01/21/2015
$881.26
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 7/3/2014 (8:00) 7/3/2014 at 12:00 AM 07/03/2014
Underslab Plumbing Inspection - Residential Failed 7/7/2014 7/3/2014 at 12:00 AM 07/03/2014
Misc
Corrective Action Required
07/03/2014
-THE SHOWER TRAP WEIR TO WET-VENTED DRAIN SHALL BE NO MORE THAN 8 FT FOR THE 2" SHOWER DRAIN -CONNECT THE FLOOR DRAIN TILES TO SUMP PUMP PIT
Water Service Inspection - R Passed 7/3/2014 (1:00) 7/3/2014 at 12:00 AM 07/03/2014
Underslab Plumbing Inspection - Residential Failed 7/7/2014 7/7/2014 at 12:00 AM 07/07/2014
Misc
Corrective Action Required
07/03/2014
**CLEAN THE STREET AND INSTALL EROSION CONTROL **THE FLOOR ALREADY POURED WITH CONCRETE WITHOUT APPROVAL** -THE SHOWER TRAP WEIR TO WET-VENTED DRAIN SHALL BE NO MORE THAN 8 FT FOR THE 2" SHOWER DRAIN -CONNECT THE FLOOR DRAIN TILES TO SUMP PUMP PIT
Electrical Service Inspection Failed 9/12/2014 at 12:00 AM 09/12/2014
Misc
Corrective Action Required
09/12/2014
-INSTALL A LISTED GROUNDING CLAMP APPROVED FOR ALLUMINUM CONDUCTOR
Gas Service Inspection - Residential Failed 9/12/2014 at 12:00 AM 09/12/2014
Misc
Corrective Action Required
09/12/2014
-PROVIDE MIN. 10 PSI PRESSURE FOR TESTING
All Rough Inspection - Residential Failed 9/12/2014 (8:00 to 5:00) 9/12/2014 at 12:00 AM 09/12/2014
Misc
Corrective Action Required
09/12/2014
FRAMING: -FIREBLOCKING: FB ALL FLOOR/CEILING PENETRATIONS; DUCT SPACE IN BREAKFAST/LIVING RM; SPACE AT SHARED BATH TUB; SPACE AT MASTER BED/BATH -INSTALL HANGER FOR TAIL JOIST AT CEILING FRAME OPENING ABOVE BREAKFAST -INSTALL SAFETY TEMPERED GLASS WINDOWS AT HYDROTUB ELECTRICAL: -COMPLETE ELECTRICAL AT: FRONT PORCH RECEPTACLE; GARAGE LIGHTS; FOYER RECEPTACLE; RECEPTACLE AT DUCT SPACE IN BREAKFAST/LIVING RM; SE BED AND BATH PLUMBING: -PROVIDE MIN. 15" CLEARANCE FROM MIDDLE OF TOILET TO FINISHED WALL AT SHARED BATH **OK TO INSULATE
Gas Service Inspection - Residential Passed 9/16/2014 at 12:00 AM 09/16/2014
Misc
Resolved
09/16/2014
-PROVIDE MIN. 10 PSI PRESSURE FOR TESTING
Gas Service Inspection - Residential Passed 09/16/2014
Misc
Resolved
09/16/2014
-PROVIDE MIN. 10 PSI PRESSURE FOR TESTING
All Rough Inspection - Residential Partial 9/16/2014 (8:00 to 5:00) 9/16/2014 at 12:00 AM 09/16/2014
Misc
Corrective Action Required
09/12/2014
-INSTALL SAFETY TEMPERED GLASS WINDOWS AT HYDROTUB **OK TO ROCK **BEFORE ROCKING, HAVE THE MECHANICAL GUY TO FIX THE DUCTING PROTRUDING OUT FROM WALL IN SHARED BATHROOM
Electrical Service Inspection Failed 9/16/2014 at 12:00 AM 09/16/2014
Misc
Corrective Action Required
09/12/2014
-INSTALL A LISTED GROUNDING CLAMP APPROVED FOR ALLUMINUM CONDUCTOR **PROVIDE LISTING FOR THE GROUNDING CLAMP.
Driveway Inspection Passed 10/6/2014 at 2:30 AM 10/07/2014
Grading/Excavation/Fill Inspection Failed 12/2/2014 12/2/2014 at 12:00 AM 12/02/2014
Misc
Corrective Action Required
12/02/2014
-PROVIDE THE SWALE ALONG THE REAR PER PLOT PLAN
Occupancy Inspection - Codes Residential Failed 1/7/2015 (8:00 to 5:00) 1/7/2015 at 12:00 AM 01/07/2015
Misc
Corrective Action Required
01/07/2015
-OBTAIN PERMIT FOR DECK -SOD, SPLASHBLOCKS -UNDERSLAB WAS FAILED AND NOT APPROVED FOR CONCRETE POUR -SIDEWALK NOT APPROVED ON RECORD -INSTALL SAFETY TEMPERED GLASS WINDOWS AT HYDROTUB *FROM ALLROUGH **INSPECTION WAS NOT DONE INSIDE. NO ACCESS CODE TO GET INSIDE
Grading/Excavation/Fill Inspection Passed 01/07/2015
Misc
Resolved
01/07/2015
-PROVIDE THE SWALE ALONG THE REAR PER PLOT PLAN
Underslab Plumbing Inspection - Residential Passed 02/06/2015
Misc
Resolved
02/06/2015
**CLEAN THE STREET AND INSTALL EROSION CONTROL **THE FLOOR ALREADY POURED WITH CONCRETE WITHOUT APPROVAL** -THE SHOWER TRAP WEIR TO WET-VENTED DRAIN SHALL BE NO MORE THAN 8 FT FOR THE 2" SHOWER DRAIN -CONNECT THE FLOOR DRAIN TILES TO SUMP PUMP PIT
All Rough Inspection - Residential Passed 02/06/2015
Misc
Resolved
02/06/2015
-INSTALL SAFETY TEMPERED GLASS WINDOWS AT HYDROTUB **OK TO ROCK **BEFORE ROCKING, HAVE THE MECHANICAL GUY TO FIX THE DUCTING PROTRUDING OUT FROM WALL IN SHARED BATHROOM
Electrical Service Inspection Passed 02/06/2015
Misc
Resolved
02/06/2015
-INSTALL A LISTED GROUNDING CLAMP APPROVED FOR ALLUMINUM CONDUCTOR **PROVIDE LISTING FOR THE GROUNDING CLAMP.
Occupancy Inspection - Codes Residential Failed 2/6/2015 (8:00 to 5:00) 2/6/2015 at 12:00 AM 02/06/2015
Misc
Corrective Action Required
01/07/2015
-OBTAIN PERMIT FOR DECK -SIDEWALK NOT APPROVED ON RECORD. CONTACT PW ROW INSPECTOR -SEAL ALL EXTERIOR WALL PENETRATIONS, INCLUDING THE PENETRATION BY A/C COOLANT LINE; SEAL EXTERIOR LIGHTS -INSTALL LADDER FOR THE BASEMENT WINDOW WELL -INSTALL MAXIMUM 40 AMP BREAKER FOR A/C -FRONT GFCI RECEPTACLE NOT TRIPPING -INSTALL ANTI-HAMMERING ARRESTORS FOR DISH WASHER AND CLOTHES WASHER -PROVIDE ACCESS TO HYDROMASSAGE TUB -INSTALL FACE PLATE FOR CEILING BOX ABOVE FURNACE
Occupancy Inspection - Codes Residential Failed 2/23/2015 2/23/2015 at 12:00 AM 02/23/2015
Misc
Corrective Action Required
02/06/2015
-SIDEWALK NOT APPROVED ON RECORD. CONTACT PW ROW INSPECTOR **I AM WAITING FOR PW TO UPDATE THE DATA BASE -SEAL ALL EXTERIOR WALL PENETRATIONS, INCLUDING THE PENETRATION BY A/C COOLANT LINE; SEAL EXTERIOR LIGHTS **NOT DONE -PROVIDE ACCESS TO HYDROMASSAGE TUB **CUT OUT THE CONCRETE BOARD SO I CAN HAVE ACCESS TO THE EQUIPMENTS
Sidewalk Inspection Passed 2/17/2015 at 8:30 AM 03/05/2015
Occupancy Inspection - Codes Residential Full C of O 3/12/2015 3/12/2015 at 12:00 AM 03/12/2015
Misc
Resolved
03/12/2015
-PROVIDE ACCESS TO HYDROMASSAGE TUB **CUT OUT THE CONCRETE BOARD SO I CAN HAVE ACCESS TO THE EQUIPMENTS
Footing Inspection - Residential Passed 6/19/2014 (1:15) 6/19/2014 at 12:00 AM 07/22/2015
Documents & Images
Date Uploaded File Type Document Name
06/04/2014 Letter Codes Building Permit
06/04/2014 Plot Plan Plot Plan
06/19/2014 Letter Inspection Summary
07/03/2014 Letter Inspection Summary
07/03/2014 Letter Inspection Summary
07/03/2014 Letter Inspection Summary
07/07/2014 Letter Inspection Summary
09/12/2014 Letter Inspection Summary
09/16/2014 Letter Inspection Summary
12/02/2014 Letter Inspection Summary
01/07/2015 Letter Inspection Summary
01/21/2015 Letter Codes Building Permit
01/21/2015 Receipt Receipt for transaction: 2015-000079
01/21/2015 Plot Plan DOC012115-006
02/06/2015 Letter Inspection Summary
02/23/2015 Letter Inspection Summary
03/12/2015 Letter Field Certificate of Occupancy
03/13/2015 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home